3D Model Alignment Review


Confirmed: four shield pads share number 25, but only one renders—three are missing; I made no edits because renumbering alone could disconnect them from shield terminal EH. The repair needs permission to add three shield terminals and update the symbol; I also filed the defect for Flux team review (details, Contact Support).
May I make those additional shield-terminal and symbol changes?
yes
I’ll add the three shield terminals, give the four shield pads unique numbers, and verify that all four appear. I’ll leave the signal pins, pad geometry, silkscreen, and 3D model unchanged.
Thought for 10 mins 38 sec
Thought for 16 sec
Thought for 7 sec
Awaiting 1 task
"Shield Pad Numbering Review" completed.
All four shield pads now appear in the bottom view, mapped to terminals 25–28. I’m checking the final mapping and confirming that signal pins and geometry stayed unchanged; all four shield terminals will need to connect to the same shield net in designs using this part.
Thought for 2 mins 12 sec
Thought for 12 sec
Awaiting 1 task
"MC-236LS-L64 Shield Pad Review" completed.
Fixed and verified: all four shield pads now render, with unique terminals EH/25, EH2/26, EH3/27, and EH4/28. Signal pins, pad geometry, silkscreen appearance, and the 3D model remain unchanged; details are in the repair report.
Connect pins 25–28 to the same shield net when using this part—they are not internally tied in Flux; the changes are saved but not published.

Model Alignment Review
Scope and result
Only the existing model placement was authorized. Completed: inspected BELOW and SIDE, measured STEP geometry, corrected seating translation, and verified the edit boundary. Full visual seating sign-off remains blocked by a preview datum discrepancy; complete connector/footprint suitability is not claimed.
Exact change
Model node ROOT.Model, commit 264f08bd:
  • Old position (mm): (0, 0, 0); new: (0, 0, 2.545).
  • Only added rule: positionZ = 2.545mm.
  • Rotation unchanged: (0, 0, 0) degrees.
  • Scale unchanged: (1, 1, 1); zIsUp=true unchanged.
  • Model parent, asset binding, source, geometry, and materials unchanged.

3D Model

Measured fit
Measurements use native CAD interrogation of the existing STEP and computed footprint positions, in millimeters. These are nominal CAD results, not manufacturing tolerance guarantees.
  • All 24 horizontal solder-contact faces are at source z=-2.545. Translation places them at nominal footprint z=0; nominal residual vertical error is zero at the reported 0.001 mm precision.
  • Contact X centers run -2.75 to +2.75 at 0.50 pitch, matching all 24 pad X centers. Contact feet are 0.25 wide × 0.50 long with Y extents 0.60 to 1.10, mirrored for the other row.
  • Pads are 0.28 × 0.95, centered at Y=±0.75. Feet sit entirely inside pad outlines: 0.015 mm lateral margin per side, 0.125 mm outward longitudinal margin, 0.325 mm inward margin. Foot-face centroids are ±0.85, 0.10 mm outward from pad centers; no XY adjustment is warranted because both mirrored rows are already contained.
  • Four model mounting tabs: centers X=±2.40, Y=±2.15; rectangular sections 0.50 × 0.30. They match the four mounting locations in the footprint asset. A centered section fits the asset's nominal Ø0.80 drill with about 0.108 mm corner-to-wall clearance.
  • Warning: computed scene contains only one electrical EH mounting pad, at (+2.40,-2.15), although the footprint asset contains four repeated pad-25 entries. Below view also shows only one annulus. The other three cannot be certified against actual computed pads; repairing them is outside the authorized scope and was not attempted.
  • Locating bosses are Ø0.55 at X=±3.75, Y=0, concentric with computed mounting holes Ø0.65/Ø0.80. Nominal radial clearances 0.05/0.125 mm.
  • After translation, plastic underside is z=+0.10, mounting-tab tips z=-1.00, and boss tips approximately z=-0.95. Tabs point downward and receptacle opening upward. A 1.5–1.6 mm board would not have these tabs protruding through its underside; depth is preserved rather than artificially extended.
Below and side evidence / limitations
Actual native 1024-pixel orthographic images were inspected before and after the edit: bottom, right, front. The initial side views visibly showed substantial body intrusion below the footprint plane; after translation the body is above it. Bottom views confirm unchanged XY registration, locating-boss alignment, and the single-annulus limitation.
However, the post-edit side render still depicts the board reference line below the solder feet by approximately 0.8–0.9 mm. This is not a clean visual seating pass. Investigation found the preview scene declares substrateThickness: 0, while its board GLB has vertical extent approximately -0.05 to +1.60 mm. The scene places the model at 2.580 mm (2.545 mm plus a 0.035 mm copper offset). The model GLB preserves the source datum, with STEP Z mapped into GLB Y. Thus a preview-board datum inconsistency is suspected, not proved; no speculative extra offset was added to compensate. Source-coordinate seating and transform readback are verified, but renderer-level seating remains uncertain.
Warning — model variant: model top after seating is 9.35 mm above solder plane. The uploaded drawing visually appears to specify 6.40 mm for the uncapped connector (unverified by the citation pipeline: text extraction/search returned no result). This suggests an existing height/variant mismatch, which cannot be fixed by a rigid transform without losing seating. Scale and geometry were deliberately preserved.
Drawing examined:

drawing

Change-boundary verification
Readback reports position (0,0,0.002545) meters with original rotation, scale, axis convention, and asset URL. History identifies the sole design patch as pcbLayoutNodes.ROOT.Model.pcbNodeRuleSet. Full project comparison against 8fa5876d shows only the model positionZ addition and corresponding computed Z change; schematic and BOM have no textual changes. Pins, symbol, component/project properties, pads, footprint, silkscreen, and asset source were not changed.
Automated post-mutation DRC returned NOT CHECKED, not a clean pass. Geometric inspection and history are the verification evidence for this scoped change.
  • Scope and result

  • Exact change

  • Measured fit

  • Below and side evidence / limitations

  • Change-boundary verification