Battery Holder Guide


I’ll research the battery holder’s datasheet and verified alternatives, then write a cited application guide in the project files, clearly marking any specifications I can’t verify.
I confirmed the distributor-listed materials, temperature range, and two functional alternatives. The manufacturer drawing lookup remains unresolved, so the guide will explicitly flag current ratings, pad dimensions, and numbered polarity mapping as unverified rather than guess.
Created a project doc

BH-18650-B1BA002 Application and Usage Guide

View Document

BH-18650-B1BA002 Application and Usage Guide
The MYOUNG BH-18650-B1BA002 is a horizontal surface-mount battery holder for an 18650 cylindrical cell, listed by LCSC as C2988620. Its standard application is providing a removable battery connection to a portable electronic device’s protection, charging, and power-conversion circuitry. LCSC product listing
Evidence status — researched October 6, 2026: Holder attributes below are explicitly labeled as distributor-listed where appropriate. The stored LCSC datasheet URL did not return a readable PDF to the research service; an alternative mirror was located, but its datasheet evidence extraction remains pending after a retry. Manufacturer current/voltage limits, exact mechanical dime...
Created the BH-18650-B1BA002 Application and Usage Guide in the project files, covering all seven requested sections with source links and two verified functional alternatives.
Manufacturer current/voltage ratings, exact footprint dimensions, and numbered polarity mapping remain explicitly unverified; an accessible manufacturer drawing is needed to resolve them.

BH-18650-B1BA002 Application and Usage Guide
The MYOUNG BH-18650-B1BA002 is a horizontal surface-mount battery holder for an 18650 cylindrical cell, listed by LCSC as C2988620. Its standard application is providing a removable battery connection to a portable electronic device’s protection, charging, and power-conversion circuitry. LCSC product listing
Evidence status — researched October 6, 2026: Holder attributes below are explicitly labeled as distributor-listed where appropriate. The stored LCSC datasheet URL did not return a readable PDF to the research service; an alternative mirror was located, but its datasheet evidence extraction remains pending after a retry. Manufacturer current/voltage limits, exact mechanical dimensions, terminal numbering, and assembly profile therefore remain unverified, not proven absent from the datasheet. General circuit/layout recommendations are engineering guidance, not MYOUNG specifications.
1. Quick Specifications

Table


ParameterValue / statusRating classification and integration implication
Manufacturer / ordering codeMYOUNG / BH-18650-B1BA002Distributor-confirmed identity; LCSC C2988620. LCSC
Intended cell format18650 cylindrical cellDistributor-listed mechanical format; does not establish chemistry, protected-cell fit, or electrical safety. LCSC
MountingHorizontal SMT, 180° typeDistributor-listed mounting style; not a standard IC package or verified land pattern. LCSC
Contact materialPhosphor bronzeDistributor-listed construction. LCSC
Contact coatingGold platingDistributor-listed; plating thickness remains unverified. LCSC
Operating temperature−25 to +85 °CDistributor-listed operating range, not a verified absolute maximum or a battery charging-temperature range. LCSC
Absolute maximum voltage / dielectric withstandUnverifiedDo not substitute the cell’s voltage for a holder insulation rating.
Continuous / pulse currentUnverifiedObtain manufacturer ratings and test conditions before assigning a maximum load or charge current.
Contact resistanceUnverifiedMeasure assembled contact drop under load; no numeric limit is asserted here.
Terminal pitch, land dimensions, body envelopeUnverifiedDo not use nominal cell dimensions or a library footprint as manufacturer verification.
Reflow profile and housing materialUnverified“SMT” alone does not establish peak soldering temperature, dwell time, or moisture handling.
Operating voltage is set by the selected cell and circuitry, not the holder. For example, TI identifies BQ24074 as a one-cell Li-ion/Li-polymer charger with a 4.2 V battery-charge target; this is an example charger specification, not a BH-18650-B1BA002 voltage rating. A different cell chemistry or charge target requires a different validated charging solution. TI product page
2. Pinout & Connections
Manufacturer terminal numbers and their polarity mapping could not be verified. The following table identifies contacts by their actual battery polarity; do not assume that pad 1 is positive or pad 2 is negative.

Table


Pin NumberPin NameDescriptionBest Practice
Unverified — positive contactBAT+Contact mating with the selected cell’s positive terminalRoute through appropriately selected short-circuit and reverse-insertion protection to the battery power path. Confirm contact-to-pad mapping by continuity with the cell removed.
Unverified — negative contactBAT−Contact mating with the selected cell’s negative terminalConnect to battery return. Tie directly to system GND only if the protection topology permits; low-side protection FETs must not be bypassed by another ground connection.
BAT+ and BAT− are explanatory net names, not verified MYOUNG pin labels. This holder interface has no enable, data, or pull-up function; do not add pull-up resistors to its battery terminals.
3. Standard Application Circuit
Removable single-cell battery power path
Use this conceptual connection for a portable device; it is not a fully specified protection circuit:

Text


Holder BAT+ ── fuse/current protection ── reverse-insertion protection ── PACK+
Holder BAT− ── battery-protection return path ────────────────────────── PACK−

PACK+ / PACK− ── charger and power-path battery interface
External DC ──── charger input
Power-path system output ── regulator ── load
Implementation guidance:
  • Choose a cell with documented chemistry, maximum charge voltage, charge/discharge limits, and temperature limits. Validate its actual diameter, length, and terminal style in the holder; protected cells and button-top cells may have different envelopes.
  • Use a protected cell or a properly designed board-level battery protection circuit that addresses overcharge, overdischarge, overcurrent, and short circuits. A charger is not automatically a complete discharge-protection solution.
  • Place a fuse or other coordinated fault-current protection near BAT+. Select its hold/trip behavior and DC interrupting capability for the selected cell and system; no universal fuse value can be recommended while holder current ratings remain unverified.
  • Provide reverse-insertion protection suitable for both charging and discharging. Do not blindly copy a one-direction ideal-diode circuit into a bidirectional battery path.
  • If charging while operating, use a charger with a validated power-path/load-sharing implementation. TI’s BQ24074 is one functional example; its system load connects to OUT rather than being indiscriminately paralleled across BAT. TI
Example charger-interface capacitors
The holder itself requires no passive components to make electrical contact. Capacitor values belong to the chosen charger/regulator; the following values are verified for the BQ24074 example only:

Table


NodeConnection / required bypass range
BATConnect to battery positive through the validated protection architecture; bypass BAT to VSS with 4.7–47 µF ceramic.
INConnect to the external DC source; bypass IN to VSS with 1–10 µF.
OUTConnect to the system load; bypass OUT to VSS with 4.7–47 µF ceramic.
Place these capacitors close to their associated IC pins with short return paths. Configure charge-current programming, input-current limiting, temperature sensing, and other support components using that IC’s complete reference circuit and the selected cell specification. The capacitor table alone is not a complete charging schematic. LED series resistors and USB CC pull-downs are not holder requirements and are intentionally omitted.
4. PCB Layout & Routing Guidelines
  • Footprint and polarity: Check the manufacturer drawing against pad spacing, solderable terminal areas, locating features, courtyard, and contact orientation before release. Exact dimensions remain unverified; print the footprint at 1:1 scale and compare with a physical sample as an additional check, not a substitute for toleranced manufacturer data.
  • High-current paths: Keep BAT+ and BAT− routes short and wide; size copper and vias for the actual maximum continuous current, transient current, copper thickness, and allowed temperature rise/voltage drop. IPC-2152 is a recognized current-carrying-capacity reference. No universal trace width or holder current rating is asserted. IPC-2152 overview
  • Thermal relief: Check the narrowest pad neck, thermal-relief spoke, and via transition, not just the main trace. Use sufficient copper connection for current while preserving a manufacturable soldering process; solid pours are not automatically preferable when they produce uneven pad heating.
  • Mechanical loading: Allow access for installation/removal and support the PCB near the holder. Keep components out of the cell insertion path and prevent exposed copper, mounting screws, or damaged-cell insulation from creating a battery short. Install the cell only after soldering and cleaning; keep it away from regulator/charger hot spots.
  • Decoupling and returns: Place charger/regulator bypass capacitors at their IC pins rather than solely at the holder. There is no differential-pair requirement for these DC power contacts; minimize loop area and keep switching-current paths away from sensitive circuitry.
5. Common Pitfalls / Things to Watch Out For
  1. Treating the holder as a protected battery pack. A removable-cell connection does not establish reverse-insertion immunity, safe charging, a discharge cutoff, or a fault-current limit. Verify polarity before connecting circuitry, implement the appropriate protection, and never connect a cell directly to an uncontrolled charging source. The holder’s distributor-listed −25 to +85 °C range must not be used as the cell’s permitted charging range. LCSC holder attributes
  2. Assuming all 18650 holders or cells are drop-in compatible. Verify the complete cell envelope, spring travel, terminal shape, land pattern, and current qualification. A similarly sized holder or a longer protected cell can require a new footprint or cause excessive contact force; a mechanically fitting replacement is not proof of electrical equivalence.
No verified drop-in replacement was established. These two parts are verified functional alternatives from other manufacturers; neither is claimed to be pin-number compatible or footprint-compatible with the MYOUNG holder.

Table


AlternativeVerified manufacturer informationCompatibility classification
Keystone 1042 — manufacturer pageOne-cell 18650 holder, SMT mounting, high-temperature nylon UL 94 V-0; manufacturer lists MSL packaging, 200 per bag.Functionally similar only. Recheck cell fit, land pattern, polarity, and electrical limits. No exact matching Flux entry was confirmed during the library search.
MPD BK-18650-PC2 — Flux libraryMPD specifies PCB/PC-pin mounting and protected button-top 18650 cells, 65–68 mm long. MPD product pageFunctionally similar only; not an SMT footprint replacement. Requires a through-hole footprint and cell-fit verification. Manufacturer’s cross-reference to another Keystone product does not establish compatibility with MYOUNG.
Supply-shortage substitution procedure: obtain the candidate drawing and current rating, compare mounting/polarity and cell envelope, revise footprint if necessary, and qualify contact voltage drop and retention under the intended operating conditions before updating the BOM.
7. Sourcing & Purchasing Guide

Table


AttributeDetails
Primary DistributorsExact MYOUNG part confirmed at LCSC — C2988620; assembly sourcing listed at JLCPCB — C2988620. Exact-part availability at DigiKey, Mouser, and Arrow was not verified. Distributor authorization/franchise status for MYOUNG was not independently established.
Packaging OptionsLCSC displays packaging as “−”, so tape-and-reel, cut-tape, tray, or bag delivery is unverified. JLCPCB displays a “Full Reel” quantity of 42; confirm the actual delivery format rather than treating a website quantity label as a manufacturer packaging specification. LCSC, JLCPCB
Standard MOQJLCPCB lists minimum 1 and full reel 42 for its assembly listing. LCSC MOQ/order multiples and the manufacturer’s standard pack quantity remain unverified. These are channel-specific ordering terms, not universal manufacturer MOQ. JLCPCB
Sourcing AdviceOrder the complete BH-18650-B1BA002 code and cross-check C2988620; do not treat suffix variants as interchangeable because their material/plating/packaging interpretation is unresolved. Prefer the manufacturer or independently confirmed authorized/franchised channels; request traceability and incoming inspection for independent-marketplace stock. Verify finish, contact geometry, retention, and solderability on samples.
JLCPCB assembly considerationsThe listing indicates Standard Only PCBA and high assembly difficulty. Confirm current assembly acceptance, process profile, and any special-handling fees before ordering. This listing does not itself verify the MYOUNG reflow limits. JLCPCB
Stock and purchasing terms change. No search-result stock count or price is represented here as a guaranteed live quote.
Sources
  • 1. Quick Specifications

  • 2. Pinout & Connections

  • 3. Standard Application Circuit

  • Removable single-cell battery power path

  • Example charger-interface capacitors

  • 4. PCB Layout & Routing Guidelines

  • 5. Common Pitfalls / Things to Watch Out For

  • 6. Popular Alternatives & Equivalents

  • 7. Sourcing & Purchasing Guide

  • Sources