NEXUS S3 Redesign
NEXUS-S3 Universal Platform Architecture v5.4
Waiting for input
Talk to Flux to get started.
Table
| ID | Decision | Engineering rationale | Benefits | Trade-offs | Future implications |
|---|---|---|---|---|---|
| ADR-001 | Use two equal 115 × 80 mm boards: lower PIB and upper CCB | Separate high-current/noisy energy functions from compute, RF and low-noise functions | Upgradeability, fault containment, thermal/RF separation, service replacement | More connectors, mechanics, cost and compatibility management | Stable PPI/PMI contracts required across generations; 40 mm stack remains provisional |
| ADR-002 | PIB is energy and hardware-safety authority; CCB is application/system authority | Safety and power limits must survive Core crashes or incompatible firmware | Deterministic safe state, independent inhibit, robust recovery | More distributed-state coordination and protocol design | PMI versioning, dual watchdogs and fault logs become mandatory |
| ADR-003 | Use a protected 20 V-class system bus | Aligns with common USB-PD SPR 20 V sources and reduces current versus 12 V | Lower copper/contact loss, practical 100 W input, future 28 V migration path | Requires local conversion for 12/5/low-voltage loads; battery coordination is more complex | Bus window and future 28 V compatibility must be version-controlled |
| ADR-004 | Provide two independent USB-C PD inputs | Source redundancy and user flexibility without unsafe passive paralleling | Failure isolation and source selection | Duplicated protection/control; source-transfer complexity | Each path needs independent telemetry, protection and certification evidence |
| ADR-005 | Do not assume USB input aggregation | Independent adapters may have mismatched grounds, voltages and policies; aggregation requires explicit current sharing | Avoids unsafe source interaction and false power claims | Platform remains limited to one selected source contract in base revision | Any aggregation feature is a separate future architecture/certification program |
| ADR-006 | Limit provisional continuous bus input to 90 W from a 100 W source | Reserve source/cable, transient, aging and uncertainty margin | Realistic operation on USB-PD SPR and clearer load-shedding policy | Heavy reference state at 89.62 W has effectively no remaining design margin | Heavy load or duty cycle must be revised/validated before topology freeze |
| ADR-007 | Treat 238.75 W Absolute Peak as battery-assist conditional | One USB source cannot provide the API 160 W transient plus platform peaks | Preserves a bounded high-power expansion concept | Requires a qualified battery, >13 A bus transient path, thermal/SOA validation | Disabled on non-battery SKUs; may be removed if pack/business case does not close |
| ADR-008 | Keep battery support optional and pack-qualified | Not every product needs storage; arbitrary chemistry is unsafe | Lower-cost non-battery SKU and controlled battery safety | Variant complexity and unresolved peak/UPS capability | Pack chemistry, cells, BMS, current, thermal and service model must be frozen separately |
| ADR-009 | Generate processor-specific rails locally on the CCB | Reduces inter-board low-voltage drop/noise and decouples compute generations from PIB | Better regulation, noise performance and Core upgrade flexibility | Adds CCB thermal/conversion complexity | PPI carries bounded input rails and discovery, not CPU-specific rails |
| ADR-010 | Separate PPI power and PMI data connectors | High-current paths and management signals need different contact, EMI and fault requirements | Cleaner return paths, keying, service and fault isolation | Additional connector/mechanical burden | Connector-family validation across provisional 40 mm stack is mandatory |
| ADR-011 | Use restricted discovery power before full module power | Mechanical compatibility alone cannot guarantee electrical safety | Unknown/incompatible modules remain safe; supports lifecycle compatibility | Descriptor infrastructure and extra power-control states | Passive ID plus active descriptor are mandatory for CCB, LSX, HSX and API clients |
| ADR-012 | Divide expansion into LSX, HSX and API classes | One universal connector cannot safely serve low-speed, high-speed and high-power needs | Clear signal-integrity, power and protection envelopes | More connector families and module design rules | Each class maintains independent versioning and reserved-pin policy |
| ADR-013 | API v1.0 is bounded, unidirectional and non-regenerative | Reverse energy can overvoltage USB sources and the system bus | Simpler safe power path and clear application boundary | Regenerative actuators require external handling or future interface | Bidirectional/regenerative API requires a new qualified revision |
| ADR-014 | Hardware emergency inhibit dominates firmware | Hazardous-energy removal cannot depend on application execution | Safe behavior during Core crash, protocol failure or reset | Additional hardware path and diagnostics; no universal safety claim | Application-specific safety analysis still required; reset cannot auto-reenergize |
| ADR-015 | Default all internal board/module interfaces to cold-mate | Provisional connectors and sequences are not qualified for live insertion | Lower electrical/mechanical risk | Service requires power-down | Hot-swap may be added only through explicit interface and connector requalification |
| ADR-016 | Make Gigabit-capable Ethernet and USB 2.0 service/data baseline Standard Tier functions | Provides application-neutral wired networking and lifecycle access | Broad usability, recovery and serviceability | Adds CCB power, routing and connector area | Higher-speed USB or PoE remain future controlled variants |
| ADR-017 | Reserve HSX for impedance-controlled PCIe/USB-class expansion | High-speed signals cannot use generic headers without return and sequencing control | Future storage/network/vision capability | Connector, stackup, clock and SI complexity | Phase 3B must confirm supported lane subset and channel budget |
| ADR-018 | Use hardware trips locally and telemetry secondarily | Software polling is too slow/unreliable for destructive faults | Fast protection and useful diagnostics | More comparators/sense paths and validation | Threshold ownership and measurement accuracy defined during topology selection |
| ADR-019 | Load-shed API, then HSX, auxiliary, LSX, Core, preserving AON last | Protect safety authority and graceful shutdown under source/thermal stress | Predictable degradation and fault containment | Application functionality may be interrupted | Power-manager firmware and hardware allocation must implement this order |
| ADR-020 | Maintain application-neutral base boards | Platform must support multiple product families without embedding prior robotics assumptions | Reuse, lifecycle flexibility and modularity | Some products need additional modules and connectors | Motors, radios, cameras and specialized I/O remain optional application modules |
Open ADR candidates