Power and Motor Driver Review
Table
| USB pair | Next routing trial within the existing outline |
|---|---|
| Receptacle → mux | Reroute the inner-layer CC1 leg and bottom raw-VBUS fan-out together. Then try the adjacent DP1/DN1 launch while preserving both plug orientations, ESD, and VBUS isolation. The fixed CC1 pad still limits the exit. Reject the previous path: it had 24 mm uncoupled and 17 mm of length mismatch. |
| SAMD21 → mux | Shift the I²S data via near (0.99, −8.04) mm and the +3V3 vias near (0.64, −6.26) and (1.83, −5.00) mm to open a shared corridor. The regulator’s SYS_5V and +3V3 copper is a second bottleneck. |
| Recovery MCU → mux | Relocate the SWDIO via near (−2.86, 27.07) mm and check the adjacent reset escape. Then test the corridor past the sensor and connector routing without moving the sensors or breaking LIM_UVOV_N. |
Waiting for input