Restore DO-41 Pad Overrides


Cleanup only: restore pad overrides
On pad nodes 37998458-7dfe-468b-ad2d-b219ef8262ce (pad 1, cathode, terminal 1) and 467fca71-03e3-4096-9b80-986d70ecd3d3 (pad 2, anode, terminal 2), set these node rules with mutate_rulesets node_rules:
  • pad 1: position "-4.35mm 0mm"; pad 2: position "4.35mm 0mm"
  • both: size "1.8mm 1.8mm", padShape "circular", padHoleType "STD", holeSize "0.9999979999999999mm", thermalRelief "Direct Connect"
    Keep terminal bindings. Make NO other changes (no symbol, model, asset, property changes). Read the pads back with get_layout tree rules both, confirm the values, then publish_part with notes 'Restore verified DO-41 pad overrides (drill 0.9999979999999999mm)'. Report the published version ID and readback.
Published version f3fa217b-74ac-40bb-a6ff-2732f9815790 with the exact requested notes. Readback confirmed pad 1 position -4.35mm 0mm, pad 2 position 4.35mm 0mm; both have size 1.8mm 1.8mm, shape circular, hole type STD, hole size 0.9999979999999999mm, and thermal relief Direct Connect.
Only those pad-rule overrides were set; terminal bindings, symbols, models, assets, and properties were not changed.

Part revision verification
Published version: bd335bea-7b05-44cf-9f7e-ee39d2e84f9f Part UID: c88fb8c5-65c0-47e7-be8d-b71b9124f787
Footprint readback
Exactly two explicit terminal pads remain; no additional pad nodes were generated by the attached KiCad asset. Their node UIDs are the terminal UIDs, preserving bindings.

Table


PadPosition mmCopper size mmHole mmTypeTerminal UID
1(-4.35,0)1.80 × 1.80 circular1.0STD plated through-hole37998458-7dfe-468b-ad2d-b219ef8262ce (terminal 1)
2(+4.35,0)1.80 × 1.80 circular1.0STD plated through-hole467fca71-03e3-4096-9b80-986d70ecd3d3 (terminal 2)
The original KiCad payload was read back from the footprint asset rule: pad drill 0.9999979999999999mm, box x=±2.60mm/y=±1.40mm, band x=-1.64mm, width 0.25mm. Explicit pads retain the permitted 1.0mm holes.
3D check

3D Model

Model node 4452d4c2-a867-4c33-be84-1fb19b79ec27 is under the footprint at (0,0,0)mm, rotation (0,0,0) degrees, physicalMaterials=true, scale override removed. STEP measurement: overall bounds (-4.75,-1.201,-3.501) to (4.75,1.201,2.401)mm. Body nominal length 4.7mm and diameter 2.4mm; body seating datum is z=0 (band geometry reaches -0.001mm). Vertical leads radius 0.4mm at x=±4.35mm, y=0. Front/top/isometric render inspected: centered body, leads concentric with pad holes, band on -X/pad1 side. No 180-degree correction required. Original 3.5mm offset was removed because it would float the body above its source seating plane.
Symbol — unresolved visual gate
Pin table confirms exactly pins named 1 and 2, numbers 1 and 2, Passive, descriptions Cathode and Anode. Added

Rectifier-diode-a31aeec2-95b7-40db-95e1-f12de25b07a0

rectifier SVG as isDefault=true; it has the cathode bar on left and standard triangular diode geometry. Symbol Pin Positions are (-40,0) and (40,0), respectively.
The symbol rendering tool still shows a generic rectangle, not the default SVG. The visual symbol check has NOT passed. Standard Symbol=Diode also produced the placeholder and was removed. A manual library/schematic symbol check or platform repair is needed before replacing board instances.
Removing terminal Part Type=Terminal caused the renderer to find zero terminals, so it was restored. This required identity property remains on both terminals; Designator Prefix=P was removed from both.
Complete change log
  • Created asset 1N4001G DO-41 P8.70 Footprint (kicad_mod, isFootprint=true), from the exact supplied URL. Footprint asset.
  • Set existing footprint node asset rule to that footprint name. Kept both pre-existing pad nodes and all their geometry/bindings unchanged; no pads removed or added.
  • Created vendor STEP asset 1N4001G DO-41 Model; renamed to 1N4001G DO-41 Model.step and re-uploaded same source to enable conversion; retained label 1N4001G DO-41 Model. Asset UID bcef717a-34bb-4d0e-bed3-93bef508e3f0. No extra STEP asset left behind.
  • Added model node Diode body under footprint: initially original 3.5mm offset, then corrected to 0mm after CAD measurement; asset rule updated to renamed model; rotation 0 0 0, physicalMaterials true, zIsUp true. Removed automatically created customShapeScale=1 rule; default scale remains 1.
  • Set terminal 1 Pin Description from Cathode (K), banded end to Cathode; terminal 2 from Anode (A) to Anode.
  • Removed Designator Prefix=P from both terminals.
  • Removed Part Type=Terminal from both temporarily, then restored because terminal recognition depends on it.
  • Changed both terminal Symbol Pin Position properties from (0,0) to (-40,0)/(40,0).
  • Set project Manufacturer Name from ON Semiconductor to requested onsemi.
  • Set project Datasheet URL from uploaded PDF URL to https://www.onsemi.com/pdf/datasheet/1n4001-d.pdf.
  • Added Standard Symbol=Diode temporarily, then removed it after placeholder result. Cleared Symbol Style (not previously present) to avoid default asset override.
  • Created default asset Rectifier diode.svg, UID ea78d6c2-87b2-4b60-a682-46292b4006b3, label Rectifier diode, cathode pin 1.
  • Manufacturer Part Number=1N4001G, project Designator Prefix=D, Part Type=Diode, remaining ratings/package metadata unchanged.
  • Published the new version listed above.
  • Created this verification document after publication.
Limitations
Native post-mutation PCB checks returned NOT CHECKED, so no clean DRC claim is made. A symbol-related feedback submission failed; no support ticket was filed.
  • Footprint readback

  • 3D check

  • Symbol — unresolved visual gate

  • Complete change log