Induction Heater Layout


A 5 A fuse can be used temporarily, but 4 A is safer and preferred for this ~3 A / 72 W design.
A 5 A fuse does not limit normal current to 5 A; depending on its time-current curve, it may carry substantially more than 5 A for seconds or minutes. That reduces protection for the perfboard wiring, chokes, MOSFETs, connectors, and supply.
If using the 5 A fuse:
  • Use it only if the supply itself has a reliable 3 A current limit.
  • Ensure the fuse is rated for at least 32 VDC; an automotive blade fuse is suitable for 24 V DC.
  • Use 14–16 AWG input wiring and heavy copper buses.
  • Do not increase the supply current above 3 A merely because the fuse is 5 A.
  • Fit the fuse in the +24 V input, close to the connector.
  • Replace it with a 4 A time-delay fuse when available.
For initial tests, set the bench supply to 0.5–1 A, verify stable oscillation, and then increase gradually toward 3 A. If your power supply cannot current-limit, I would not recommend powering this build with the 5 A fuse alone.
E102 20Kv is this ceramic cap to large to substitute C3???
No. 102 means 1,000 pF = 1 nF = 0.001 µF. C3 requires 100 nF = 0.1 µF, normally marked 104.
Therefore, the E102 is 100× too small in capacitance. Its 20 kV rating is harmless electrically but unnecessary, and the part may be physically large with long leads—poor for high-frequency bypassing.
For C3, look for:
  • Marking: 104
  • Capacitance: 100 nF / 0.1 µF
  • Voltage: 50 V minimum; 100 V preferred
  • Type: ceramic disc or small film
  • Mount with the leads as short as possible
The required part may say 104, 104K, 104Z, 0.1uF, or 100nF.

Schematic of Prusa 24V Induction Heater Controller

Prusa 24V Induction Heater Controller

Prusa 24V Induction Heater Controller thumbnail