Project Description Punctuation Edit


Single project description punctuation edit, NO PUBLISH. Read actual current metadata description/Description property. Preserve all text. If last character is '.', unchanged; otherwise trim trailing whitespace and append exactly one period. Only description mutation; no other metadata/design/sharing/datasheet/MPN edits, no docs, no publish, no child threads. Verify saved readback. Report canonical URL, exact before/after, changed/already correct/failed, readback result and zero publish calls.
Status: changed. Canonical URL: /jharwinbarrozo/str2n2vh5
Before: N-channel 20 V, 0.025 Ohm typ (0.03 Ohm max @ VGS=4.5V), 2.3 A STripFET H5 Power MOSFET, 0.35 W, SOT-23-3, marking STD1
After: N-channel 20 V, 0.025 Ohm typ (0.03 Ohm max @ VGS=4.5V), 2.3 A STripFET H5 Power MOSFET, 0.35 W, SOT-23-3, marking STD1.
Saved readback matched exactly. Only the description was edited; zero publish calls.

Parametric Conversion Verification
Result
  • Existing part modified directly, without replacement or delegation.
  • Actual project URL: /jharwinbarrozo/str2n2vh5
  • Part UID: 82e3538e-3e26-4df1-8345-8d2b4bed90d3 (unchanged).
  • Stored canonical property: Symbol Style: parametric-v1, verified by project metadata readback. Property definitions list parametric-v1 as the latest Parametric option.
  • Removed custom symbol SVG count: 1. Filename: nmos-symbol.svg; asset UID 6f9e62f8-4956-4c14-adcb-172924be5853, previously default=true.
  • Remaining symbol SVG count: 0. Full asset readback returned no assets; there were no suffix-associated SVGs or unrelated image assets in the initial asset inventory.
Before and after mapping
All values below are identical before and after. Pad UID equals the corresponding terminal element UID.

Table


PinNameElectrical typeTerminal element / mapped pad UIDPad X,Y (mm) before → after
1GInputa28cbf0f-7c8c-4a15-b781-24e57baaf246(-0.97,+0.97) → (-0.97,+0.97)
2SPassive11317605-d005-45dd-9a7a-60d5f70eaf19(-0.97,-0.97) → (-0.97,-0.97)
3DPassive69af0e97-eda9-4633-97c1-5b8165637ba2(+0.97,0) → (+0.97,0)
Each terminal retains its internal terminal UID 111bf4e4-02dd-41bb-a137-c0a32607d321, Terminal part UID 835bf3e1-33dd-41bb-a166-c0a31607d645, description, and existing Symbol Pin Position. All three physical terminals appear exactly once. No connections existed before or after.
Native symbol properties

Table


PinPin GroupTerminal OrderPin OrientationSection / suffix
GGate1Leftblank / blank
SSource1Bottomblank / blank
DDrain1Topblank / blank
Orders are unique and consecutive within each singleton group; one composite symbol remains. The parser accepted functional Gate/Source/Drain names, although these are not in its generic autocomplete suggestions.
Preservation evidence
Before/after full PCB-tree readbacks are identical:
  • Native footprint UID 82e3538e-3e26-4df1-8345-8d2b4bed90d3.defaultFootprint retains package SOT-23, packageSize 1.475mm 2.895mm 1.145mm, pinPitch 0.97mm 1.94mm, pinSize 0.48mm 0.95mm 0.1325mm.
  • Pin 1 remains top-left in the requested convention: -X,+Y, at (-0.97,+0.97) mm.
  • Active generated model UID 82e3538e-3e26-4df1-8345-8d2b4bed90d3.defaultFootprint_model retains computed package SOT-23; original inactive model 3f7f1039-a4eb-4c22-97cf-8a5416c8fa1c remains untouched.
  • Active designator text UID 82e3538e-3e26-4df1-8345-8d2b4bed90d3.defaultFootprint.shapes_designator retains dynamic content = this.element.designator, computed Q#, position (0,2.4475) mm, font 0.7 mm, Top layer, and active=true.
  • Native silkscreen geometry and inactive marker were untouched. The native footprint's inline silk SVG is not a custom schematic symbol asset and was correctly preserved.
  • Manufacturer, MPN, description, designator prefix Q, and all other original project metadata were retained. Datasheet URL remains https://www.st.com/resource/en/datasheet/str2n2vh5.pdf (metadata preservation only; no new datasheet research performed).
  • No downloaded CAD, replacement footprint, or handmade pads were used.
Render and publish
  • get_symbol pin table succeeded: 3 pins, correct groups/order/orientations/types.
  • get_symbol image succeeded: one native rectangular parametric symbol with G left, D top, S bottom. The symbol inspection renderer labels it MAIN; this is not the PCB dynamic designator. No render limitation blocked verification.
  • Republish succeeded with detailed change notes.
  • Published version: c5cfa6ca-c986-4f53-9b9b-fcfa374fe293.
  • Published URL: /jharwinbarrozo/str2n2vh5
Incomplete steps
None. This record documents a symbol conversion and preservation check, not a new electrical or land-pattern datasheet audit.
  • Result

  • Before and after mapping

  • Native symbol properties

  • Preservation evidence

  • Render and publish

  • Incomplete steps