UIDb89a7117-de6a-4d4c-825c-c3d303d7d0d6 owner intendedjharwinbarrozo URLhttps://www.flux.ai/jharwinbarrozo/srl05-tp~pg8 version82d6b62e-4303-48ab-aeb6-1b3964353454. Created resumed run. No children or other projects.
Confirm actual personal owner and UID/version; pin names/types/count; pad count/mapping/distinct/nonoverlap; coords sizes pitch row span; top-view numbering/orientation/pin1; bodyXY; model-node presence configured planar and full generated lead fit. Separate internal pass from source qualification. Renderer known omits parametric nodes: full fit unverified if unavailable, no external asset requirement. Repair confirmed source-backed errors only. No courtyard/assembly criteria.
Deliver
Final JSON all statuses actual coords/dimensions/gaps/changed/owner/UID/URL/latest_version. Save detailed own-project report. Do not republish unchanged. After confirmed fixes committed publish corrected NEW version of existing SAME UID and return new version ID.
I’ll verify the active part’s identity, pin mapping, footprint geometry, and model configuration, then save the findings. I’ll repair only source-confirmed errors and publish a new version only if a repair is needed.
Latest published version: 82d6b62e-4303-48ab-aeb6-1b3964353454, independently confirmed by version history (one version).
Design changes: none. No source-confirmed geometry or functional errors were established. This report is the only addition. Not republished unchanged.
Pin and pad mapping — internal PASS
Six distinct terminals, six distinct enabled Top pads. Each pad UID equals its terminal element UID, giving direct one-to-one mapping. No duplicated or missing pin numbers. The generic Terminal's underlying pin name is reported as undefined; the terminal designator carries the intended exported pin name.
All coordinates and dimensions below are millimeters, local footprint coordinates, +Y up. Root, footprint, pad container and model transforms are zero. Tree numeric geometry is returned in meters and was converted to mm.
Table
Number
Name
Type
UID
X
Y
Rotation degrees
1
INPUT LINE 1
Passive
9289cf3b-b73b-40a7-93aa-9f1231f5da56
-1.30
+0.95
270
2
GND
Ground
aea2f8de-57ad-4db7-9191-d817728a50f0
-1.30
0
270
3
INPUT LINE 2
Passive
e05ff39c-06f9-49dc-8296-9bf7a401537b
-1.30
-0.95
270
4
INPUT LINE 3
Passive
ba28b0b3-1876-4906-ae15-d37dc450091c
+1.30
-0.95
90
5
VBUS
Passive
ef322293-f86a-465e-8706-8ff832761c8d
+1.30
0
90
6
INPUT LINE 4
Passive
38c9230e-7226-4e2b-b95f-ee5a2d5926a8
+1.30
+0.95
90
Functional assignment matches the supplied previously validated source evidence: pins 1/3/4/6 input lines, 2 GND, 5 VBUS. Passive signal and VBUS clamp-rail types avoid treating the protection array as a signal driver or ordinary powered IC. GND is Ground.
Pad geometry — internal PASS, land-source qualification UNVERIFIED
Each rectangular pad is local size 0.70 × 1.00 mm, rotated 90 or 270 degrees, so footprint-axis occupied size is X=1.00 × Y=0.70 mm.
Pitch on each three-pad column: 0.95 mm.
End-to-end center span on each column: 1.90 mm.
Opposing-column center separation: 2.60 mm.
Adjacent same-column copper gap: 0.95 − 0.70 = 0.25 mm.
Opposing-pad inner copper gap: 2.60 − 1.00 = 1.60 mm.
Full copper envelope: X −1.80 to +1.80, Y −1.30 to +1.30; 3.60 × 2.60 mm.
Six distinct positions and no pairwise rectangle overlap. Minimum copper-to-copper gap is 0.25 mm.
Manufacturer package lead pitch D is 0.95 mm typical. Thus the pitch is source-qualified. Manufacturer overall physical lead span C is 2.20–3.20 mm. This is not a recommended pad-center span. Pad size and column spacing remain unverified against an authoritative recommended land pattern, following the two prior unsuccessful focused land queries dsq_35bc8ddde8e69c2ed029 and dsq_710ff82abdbe236dc18a. Internal nonoverlap is not a solderability or assembly qualification.
Top-view orientation and pin 1
Actual numbering is 1/2/3 down the left column and 6/5/4 down the right, viewed from Top with +Y up. This has the standard counterclockwise numbering relationship. Pin 1 is at (−1.30,+0.95). The manufacturer top-view description identifies a dot at pin 1.
A silk asset includes a dot at raw SVG coordinates (−2.0885359,−1.65) mm, radius 0.2286 mm, and lines at raw Y ±1.65 mm, X ±1.30 mm. The raw SVG Y sign must not be equated to local PCB Y without confirming asset registration. The 2D layout renderer did not display this part footprint. Therefore rendered silk-dot registration to pin 1 remains UNVERIFIED; no speculative marker or pad move was performed. Source-exact rotated orientation is partially verified (numbering topology and pin-1 coordinate known; rendered marker registration unavailable).
Source body width B: 1.30–1.80 mm; configured X=1.55 is the midpoint and within range.
Source body length H: 2.70–3.10 mm; configured Y=2.90 is the midpoint and within range.
Configured height 1.175 mm was read but not independently source-qualified in this verification.
Model node present and active: b89a7117-de6a-4d4c-825c-c3d303d7d0d6.defaultFootprint_model.
Model position (0,0,0), rotation (0,0,0), scale (1,1,1), Z-up=true, Top. Package and body dimensions inherited correctly from footprint. No external 3D asset is required for this parametric model.
Configured body rectangle X ±0.775, Y ±1.45. Pads' inner X edge is ±0.80: configured body-to-inner-pad planar gap 0.025 mm. End pad copper extends to |Y|=1.30, inset 0.15 mm from body ends. This is only the configured body/pad relationship, not generated-lead verification.
Full generated model lead fit UNVERIFIED. The targeted top/isometric render failed with: “The project has nothing to render in 3D: no board geometry and no node with a 3D model asset.” This renderer omits the configured parametric model. Generated lead span, lead-to-pad contact, pin-1 model marking, and height/standoff fit were not observed and are not claimed to pass.
Platform checks
Current component checks: project metadata SUCCESS; required properties SUCCESS; terminals SUCCESS; excluded terminals SUCCESS. Parametric symbol properties are INFORMATIONAL for all six terminals (Pin Group, Pin Orientation, Section unset), not errors. No source-backed mandatory change follows from that informational finding. Requested copper/invalid-pad checks did not return individual DRC results for this part project; nonoverlap was independently calculated from the actual pad geometry instead.
Disposition
Internal pin/pad structure and nonoverlap: PASS. Body XY: SOURCE-QUALIFIED nominal configuration. Footprint pad-size/row-span land qualification, rendered marker registration, and full parametric generated-lead fit: UNVERIFIED. No courtyard or assembly acceptance criteria were applied. No error was confirmed that justifies repair or republishing. Before fabrication, obtain a qualified land pattern and inspect generated leads/marker in a renderer that displays this parametric part.