Project Description Punctuation Update
20V 3A N-Channel enhancement-mode MOSFET, RDS(on) 27mΩ max @VGS=4.5V, VGS ±8V, SOT-23 (marking S2.)20V 3A N-Channel enhancement-mode MOSFET, RDS(on) 27mΩ max @VGS=4.5V, VGS ±8V, SOT-23 (marking S2.).0c6e6815-d08e-4bf7-aff2-3c26b08e9b75.parametric-v1. Project metadata readback confirms Symbol Style = parametric-v1. The project-property mutation issued a generic non-standard-property-name warning, but stored the canonical label and value successfully.si2302-symbol-d1105328-be93-4501-8c80-ac43a7c9ba87
346cafbd-b5b1-4258-8861-ea50163da88f. No suffix-associated SVG symbol assets existed. Remaining SVG symbol assets: 0; asset readback returns no assets. No unrelated images were removed. Embedded footprint silk is preserved, not a schematic symbol asset.Table
| Pin | Name | Electrical type before → after | Terminal element / physical pad UID before = after | Pad center before = after, mm |
|---|---|---|---|---|
| 1 | G | Input → Input | b3f90990-8af7-4f11-8157-c0c0aa7a5ed5 | (-1, +0.95) |
| 2 | S | Passive → Passive | 64216033-30c1-4410-ba6f-04e293a2ee62 | (-1, -0.95) |
| 3 | D | Passive → Passive | 0814ed4b-3fef-498c-a8ad-9b49ebfacc92 | (+1, 0) |
111bf4e4-02dd-41bb-a137-c0a32607d321 remains unchanged for each terminal element instance. Terminal names, descriptions, numbers, electrical types, symbol position vectors, element IDs and pad mappings were preserved. Schematic metadata and rendered pin-table readbacks agree.= this.element.designator, computed Q#, at (0,+2.45) mm with 0.7 mm font. Metadata, manufacturer, MPN, datasheet URL, electrical properties and Standard Symbol N-Channel MOSFET are unchanged.get_symbol image rendering succeeded using the current working version (empty version selector); the literal HEAD selector was rejected by this endpoint. Render shows one rectangular MAIN body with G left, D top and S bottom, consistent with the requested native parametric layout. Pin-table rendering confirms 3 pins with the intended groups, orders and orientations. The image is a diagnostic rendering and does not itself verify all editor graphics or native 3D lead fit; those are not claimed. No custom MOSFET artwork remains.4d6aeed0-8ed8-4f4f-963b-b792ed99466d. Release notes record the native parametric conversion, deleted asset, functional groups, preserved pin mapping, native SOT-23 footprint/CAD, top-left pin 1, dynamic designator and successful symbol render.jharwinbarrozo/si2302-tp~xgk, part UID 0c6e6815-d08e-4bf7-aff2-3c26b08e9b75, was edited. Corrected existing part republished as version 90f1ce59-986d-4414-a675-6b325789c06b: /jharwinbarrozo/si2302-tp . Publication is configuration-verified, not full visual sign-off.Table
| Assigned item | Status | Evidence / limitation |
|---|---|---|
| Inspect assets and properties | Completed | Initially no symbol assets; project identifies MCC SI2302-TP, Transistor/MOSFET, SOT-23, prefix Q. |
| Configure graphical enhancement NMOS symbol | Completed (configuration and source only) | Default schematic SVG added; native symbol resolver reports data-symbol-style="custom". Source has isolated gate, segmented enhancement channel and inward bulk arrow tied to source. |
| Verify effective non-box symbol in native view | Failed / blocked | get_symbol image and SVG continue to show a rectangular diagnostic body, both for built-in Standard Symbol and custom SVG. Output does not contain uploaded SVG paths. Effective application appearance cannot be certified by this inspector. Requires editor-side check before publication. |
| Pin numbers, types and mapping | Completed | Three pins exactly once: 1 G Input; 2 S Passive; 3 D Passive. Same terminal UIDs map to native package pads. |
| Preserve native footprint and generated CAD | Completed | No footprint/model edits, manual pads, or CAD assets. Native SOT-23 package and Model node remain active. |
| Pad rotated axes | Completed | Native pads local 0.80 × 0.90 mm, quarter-turn rotations, yield global X 0.90 × Y 0.80 mm; row span is global X. |
| Dynamic visible designator | Completed | Existing text expression = this.element.designator, computed Q#, active, at (0, +2.45) mm with 0.7 mm font. Q# appears in attempted 2D image. |
| Full 2D footprint visual check | Failed / blocked | Layout image returned silk/designator but omitted native parametric pads. Region-filtered 2D read returned no matching items. Geometry instead checked from computed node tree. |
| Native 3D visual check | Failed / unavailable | get_nodes render reports no board geometry and no node with a 3D model asset. Native generated Model node exists, but this rendering endpoint cannot display it. No external CAD was added as a workaround. |
| Publication | Completed with visual limitations disclosed | Version 90f1ce59-986d-4414-a675-6b325789c06b; existing part UID retained. |
Standard Symbol = N-Channel MOSFET (commit 971c6508). The inspector reported standard style but still drew a rectangle.si2302-symbol-d1105328-be93-4501-8c80-ac43a7c9ba87
346cafbd-b5b1-4258-8861-ea50163da88f. Flags: isDefault=true; isFootprint=false; is3dModel=false. No native footprint/model asset was replaced.986b61f6).e71846ed): G (-20,0), D (8,+24), S (8,-24). SVG Y direction is inverted relative to symbol coordinates: drain is at SVG y=-24, source y=+24. Pin numbers, types, names, terminal UIDs, schematic terminal placements and physical pad mappings were not changed.get_schematic and get_symbol pins reads confirm:Table
| Number | Name/type | Terminal / pad UID | Symbol anchor | Physical pad center (mm) |
|---|---|---|---|---|
| 1 | G / Input | b3f90990-8af7-4f11-8157-c0c0aa7a5ed5 | (-20,0) | (-1,+0.95) |
| 2 | S / Passive | 64216033-30c1-4410-ba6f-04e293a2ee62 | (8,-24) | (-1,-0.95) |
| 3 | D / Passive | 0814ed4b-3fef-498c-a8ad-9b49ebfacc92 | (8,+24) | (+1,0) |
si2302-symbol-preview
commentFileId-ef65b03eb099b38e6aa6c623530349b6c7022b5a1ba58f0311f083c5541b5646
e3f32358 restores Standard Symbol = N-Channel MOSFET and removes Symbol Style; default enhancement-NMOS SVG remains present. Independent read-only review confirmed native geometry, exact pin mapping/types, native model size/origin, dynamic text, and zero reported errors/warnings. Inspector still displays a fallback rectangular outline, so actual editor symbol appearance remains unverified. Native model lead fit, seating, pin-1 alignment, and complete generated-pad visual rendering were unavailable; no external CAD or manual-pad workaround was introduced.dsq_9e676a13d244594b46fb (ds1–ds4) and dsq_95d417502982d911a561 (ds4–ds17). Pads and package dimensions are supported by the latter source.Approved native parametric conversion — 2026-10-21 (current disposition)
Before/after mapping — identical
Footprint, CAD, designator and render checks
Publication and incomplete items
Scope and disposition
Precise mutations
Read-only verification
Source-only visual evidence
Remaining release warning