Edit ONLY current existing project jharwinbarrozo/rn1405clf~39k. Read actual saved project description/Description. Preserve exact text; if already ends '.', leave unchanged; otherwise trim trailing whitespace and append exactly one period. Description mutation only. No publish calls, new parts, sharing, design, URLs, MPNs, other metadata, or docs. Verify saved description via get_project readback. Return canonical URL, exact before and after, changed/already correct/failed, readback verified, zero publish calls. Fully specified single edit; skip lengthy skills/docs.
Only active RN1405,LF, part UID 4351761a-d959-47cb-a94c-9ed8d2267303, was edited. Existing published identity retained; no replacement part was created.
R1 connects external B to the internal transistor base; R2 connects that internal base node to E. Thus the external input is not a bare BJT base, and R2 is not directly across external B and E.
Absolute maxima: VCEO = 50 V, IC = 100 mA, PC = 200 mW, at Ta = 25 °C unless otherwise stated.
Replaced MOSFET-only Drain to Source Voltage and Continuous Drain Current metadata with Voltage Rating = 50 V, Max Current = 0.1 A, Power Rating = 0.2 W. Transistor Type remains NPN.
Exact ordering reference: DigiKey RN1405,LF explicitly lists TO-236-3 / SC-59 / SOT-23-3, supplier package S-Mini. Native package code retained as SOT-23-3; this does not equate Toshiba S-Mini dimensions to every generic SOT-23 package.
Native symbol
Symbol Style = parametric-v1; Standard Symbol = NPN Transistor. No custom symbol asset is listed. The available native symbol render resolves to a three-terminal parametric block, not a drawing of the internal resistor network; the network is documented above and in the part/pin descriptions.
Table
Physical pin
Name
Electrical type
Orientation
Group
Order
1
B
Input
Left
Base Input
1
2
E
Passive
Bottom
Emitter
1
3
C
Passive
Top
Collector
1
All three appear exactly once in the pin table. A blank Section is intentional for this simple three-pin device; the checker reports this as informational only.
Package and reference land pattern
Toshiba identifies S-Mini as package 2-3F1S.
The manufacturer package guide gives nominal body dimensions 1.5 × 2.9 × 1.1 mm and the S-Mini land example uses 0.8 × 1.0 mm pads, row center spacing 2.4 mm, and spacing between the two adjacent pads 1.9 mm.
Native footprint generator retained: package = SOT-23. No hand-created pads, imported footprint, or downloaded CAD used.
Table
Native footprint rule
Stored value
packageSize
1.5mm 2.9mm 1.1mm
pinPitch
0.95mm 2.4mm
pinSize
0.8mm 1.0mm 0.16mm
The native SOT generator interprets pitch X along the paired terminals and pitch Y across the rows. Readback confirms these actual pad centers in the XY-up frame:
Table
Pin
Center X (mm)
Center Y (mm)
Effective copper X × Y (mm)
1 B
-1.2
+0.95
1.0 × 0.8
2 E
-1.2
-0.95
1.0 × 0.8
3 C
+1.2
0
1.0 × 0.8
Three distinct enabled rectangular pads retain the original terminal UIDs. Local pad size is 0.8 × 1.0 mm, rotated 90°/270°, producing the global sizes above. Pin 1 is top-left (-X,+Y). The native silkscreen marker is beside pin 1. Copper does not overlap: paired pads have 1.1 mm edge separation and opposing rows have 1.4 mm edge separation. The reference land pattern is nominal guidance, not a solder-process qualification.
Model and text checks
Exactly one native generated Model node exists below the footprint; package = SOT-23, active = true, packageSize = 1.5 × 2.9 × 1.1 mm, position/rotation = zero, scale = 1, zIsUp = true, physicalMaterials = true, showEdges = false. No model asset is attached; this is intentional native parametric CAD, not missing downloaded CAD.
The 3D inspection renderer includes asset-backed models only and reported 0 asset-backed models. Therefore actual native-model lead fit, pin-1 geometry, detailed lead dimensions, and seating are unverified. The node/rule evidence establishes configuration, not visual fit.
Generated dynamic designator is active, content expression = this.element.designator, resolves to Q#, at (0, 2.45) mm, generated font size 0.7 mm. The 2D and bare-footprint 3D views show it clearly above the body area.
Test overrides for generated model/text were removed when they did not alter effective readback; no unsupported hand geometry remains.
Checks and limitations
Component checks: Incomplete Project Info, Missing Properties, Missing Terminals, and Excluded Terminal all report Success. Missing Parametric Symbol Properties is Informational (Section absent), with no error or warning.
Part-level invalid-pad, overlapping-copper, and silkscreen DRC validators did not return results. These checks are unverified, not declared clean. Exact pad geometry and text positions were read independently as described above. The 2D SVG inspector omits generated part-project pads; the tree provides their coordinates, and the bare-footprint render visibly shows three separate lands. The schematic image is a tool-generated parametric block and does not visually represent R1/R2.
A final native-editor 3D visual fit/seating review remains recommended before treating the CAD as assembly-verified.