Verify/repair ONLY active REF35409QDBVR UID 3f580abb-c0ca-49a0-837a-221940380bbc owner jharwinbarrozo URL /jharwinbarrozo/ref35409qdbvr initial 29f2f1a6-70cc-4298-8ec6-f9f063433eae. No children/anchor/placements/sharing. Query own manufacturer PDF exact complete suffix ordering pins/types/package. Creation map 1 GND,2 GND_2,3 EN,4 VIN,5 NR,6 VREF; pin2 must retain functional datasheet name GND not GND_2. Verify types. Query land/body geometry then second focused if insufficient; only verified geometry corrections else name unqualified defaults. Inspect actual pins/pads count/types/1:1 mapping global dimensions positions pitch span top-view orientation pin1 nonoverlap min gap and model/body node. Intended parametric SOT23-6 model, renderer omission not absent. Confirm identity before writes; confirmed fixes only, unchanged no publish. After fixes committed publish corrected EXISTING part new version return ID. Compact complete report identity/version/changed flags measurements evidence handles all gaps; no production-ready claim.
I corrected NR’s electrical type and the six pad sizes to match TI’s example land pattern. Pin 2’s rename to GND is blocked by the duplicate-name validator; I filed an internal ticket for Flux review and will disclose that gap in the new version.
Own lookup used TI REF35 manufacturer PDF via datasheet query (not web snippets). Exact REF35409QDBVR is an orderable SOT-23 (DBV), 6-pin device, large tape-and-reel, 3000 q...
Repaired the existing REF35409QDBVR, UID 3f580abb-c0ca-49a0-837a-221940380bbc, and published version 7325fde7-fb77-4d72-be87-15e70ce85168: NR is now Output, and all six lands match TI’s example dimensions. Pin 2 remains GND_2 because the duplicate-name validator rejected GND; I filed an internal quality ticket for Flux review—this remains a partial repair, not a production-readiness approval. Complete measurements, change flags, evidence handles, model findings, and verification gaps are recorded in project files: Part Verification Results.
Own lookup used TI REF35 manufacturer PDF via datasheet query (not web snippets). Exact REF35409QDBVR is an orderable SOT-23 (DBV), 6-pin device, large tape-and-reel, 3000 quantity.
Pin functions: 1 GND Ground; 2 GND Ground; 3 EN Input; 4 VIN Power; 5 NR Output; 6 VREF Output. Pin 1 is internally shorted to pin 2.
DBV0006A package body is 1.45–1.75 × 2.75–3.05 mm; maximum height 1.45 mm; lead span 2.6–3.0 mm; pitch 0.95 mm; outer-lead-center span 1.9 mm. Pin-1 index area is top-left.
TI example land pattern uses six 1.1 × 0.6 mm pads, R0.05 mm typical, 0.95 mm pitch and 2.6 mm column-center spacing.
Confirmed repairs
Pin 5 NR: Passive → Output (commit c6d1fd6f).
Six source pads: local size 0.7×1.0 → 0.6×1.1 mm, with R0.05 mm rule. Existing 90°/270° rotations give global 1.1×0.6 mm dimensions. Source node geometry corrected directly, not consuming-board overrides.
Pin 2 rename GND_2 → GND attempted once by exact UID a14eee02-a4b0-4854-80ec-78ea04f49191, rejected by duplicate-designator validator; no name change landed. Pin 1 already has GND. An internal part-quality ticket was filed successfully; no ticket ID was returned. Flux review is needed for repeated functional pin names; Contact Support.
Actual post-fix geometry and mapping
Read all six terminal records and all nine PCB tree nodes. Each terminal UID is also its pad UID; no missing or extra pad. No nets/wires were created.
Coordinates below are mm, global X right/Y up; Z=0. Local pad size .6×1.1 mm, global 1.1×.6 mm, all on Top, rectangular copper with R.05 input rule; no hole field was returned.
Table
Pin
Actual name
Type
X
Y
Rotation
UID
1
GND
Ground
-1.3
+.95
270°
bdd4df6f-a676-4c2b-9ab0-686001adca38
2
GND_2 (unresolved)
Ground
-1.3
0
270°
a14eee02-a4b0-4854-80ec-78ea04f49191
3
EN
Input
-1.3
-.95
270°
bb7d3b27-1bec-4fe4-b29c-8240bf717381
4
VIN
Power In
+1.3
-.95
90°
9512ff62-4146-4a26-b552-a426a2876e74
5
NR
Output
+1.3
0
90°
25a2c4c6-aa7d-4b7a-a106-db9a56fa9775
6
VREF
Power Out
+1.3
+.95
90°
16572dc0-60ff-4e94-a4c0-caee83c9dfeb
VIN Power In is the platform-specific supply direction; VREF Power Out is retained as the specific reference supply output classification rather than generic Output.
Measured/derived: row pitch .95 mm, outer row span 1.90 mm, column-center span 2.60 mm; copper bounding box 3.70×2.50 mm; same-column minimum gap .95−.60=.35 mm, opposite-column gap 2.60−1.10=1.50 mm. No copper overlap. Pad-1 center is top-left (-1.30,+.95). Silk asset pin-1 circle raw SVG center (-2.08853589,-1.65) mm is Y-down and converts to top-left (-2.08853589,+1.65) in Y-up coordinates. Existing marker retained.
Footprint and Model nodes both explicitly carry parametric SOT-23-6, packageSize 1.60×2.90×1.175 mm; footprint/model origin (0,0,0), rotation zero, model scale (1,1,1). This is an intended parametric model, not an absent model. Nominal body dimensions lie within manufacturer outline ranges; retained, not converted to worst-case envelope. Footprint UID: 3f580abb-c0ca-49a0-837a-221940380bbc.defaultFootprint; model UID adds _model.
Checks and remaining gaps
Missing Properties, Missing Terminals and Excluded Terminal checks report Success.
Mutation DRC did not return results for several checks (including Invalid Pads, Invalid Layer, Silkscreen overlap and others); no comprehensive clean DRC claim.
Pin 2 still GND_2: requested exact functional-name requirement remains unmet due to platform collision.
Focused orientation query could not retrieve explicit top-to-bottom numbered figure support; package index top-left plus actual coordinate ordering checked, but full numbered top-view figure not independently rendered.
2D part renderer omitted footprint content; this omission was not treated as missing pads/model. No independent 3D render or CAD tessellation was obtained.
Corner radius input persisted but computed corner radius was omitted by tree response; no exported pad contour check.
Mask/paste expansion, full stencil/courtyard, exact 3D lead shape, tolerance envelope and manufacturing exports were not qualified. Nominal parametric model is not a mechanical acceptance envelope.
This is a partial repair/verification, not a production-ready claim.