Status: concept only, awaiting visual approval; not a production-ready enclosure. This record supersedes the initial R2 renders. No PCB, component, component-model or connectivity changes were made by the enclosure executor. Detailed joints, retention hardware and structural validation remain deferred.
Current geometry and assets
3D Model
3D Model
3D Model
3D Model
These are concept assets, not released manufacturing files. Existing knob/coupon assets remain untouched.
Geometry-bound views
All views below use the same repaired concept and existing PCB/component models, not generative imagery or reconstructed proxies. Parts lacking model assets cannot appear in these renders.
Closed exterior
Closed R2 repair1
Callouts: chamfered rectangular shell; flush lid outline with shadow line; three potentiometer shafts, footswitch and two LED apertures; opposite jack windows; end DC opening. Six shallow recesses indicate future lid screw locations, not installed screws or qualified seats. D1 is recessed beneath the roof surface.
Lid off — actual PCB inside
Open R2 repair1
Callouts: both CN windows are open to the base rim for vertical board installation; the lid tabs complete their upper boundaries. Four conceptual mounting-hole seats locate the support arrangement; final positive retention is not implemented.
Underside — four shallow foot pockets
Underside R2 repair1
The inspected underside shows all four pockets and no protruding LED leads. Rubber feet themselves are not modeled or selected.
Additional inspected cameras: open yaw90/pitch25; closed yaw270/pitch10. All cameras Z-up, zoom1, perspective/presentation, 1024 square. Installed part transforms were unchanged for every view; only the lid enabled state was temporarily false. It is restored true.
Fixed datum and selected envelope
Table
Parameter
Value mm
Basis/state
PCB
100 × 60, corner R3
Layout, fixed
PCB thickness
1.29936
Stackup, fixed
PCB top / underside
Z0 / −1.29936
Fixed datum
Exterior bounds
X−54…71, Y−39…39
Selected concept
Exterior shell
125 × 78 × 39.4
Derived, excludes protruding controls
Corner treatment
6 mm planar chamfers
Selected per requested chamfer intent
Cavity ordinary bounds
X−51…68, Y−36…36
Selected around fixed assembly
Wall / floor / roof
3 / 2.4 / 2.4
Fixed standard
Inner floor / bottom
Z−14.6 / −17
Derived from LED lead envelopes
Seam / lid underside / roof top
Z20 / 20 / 22.4
Selected concept
Foot pocket size
12 × 7 × 0.6
Concept; foot fit provisional
Foot pocket centers
(−45,±30), (62,±30)
Selected
Inner chamfer profile is offset from outer profile to preserve nominal wall thickness. Pocket backing preserves 2.4 mm local floor thickness. The shell is intentionally asymmetric about the PCB datum; the PCB is not recentered.
Saved footprint/model transforms and existing measurements. Generous assembly windows, not final manufacturer panel-cutout claims
J1 PJ-037AH
−X exit; Y0; width10.2; base notch Z−0.4…20; closed top11.3
Saved transform and recorded housing height10.9/width8.9; housing opening centerZ5.45 differs from electrical axisZ6.5
VR1/VR2
(2.870891,18.288974), (2.870891,−21.231026), Ø6.6
Prior measured axes cross-checked with placement
VR3
(−22.847109,−0.071026), Ø6.6
Same
S1 FS5700
(39.9735,1.706), Ø12.6
Recorded mechanical axis; nearby model transform axis (39.9388,1.7426); exact final hardware stack unverified
LED1
(−35.0358,−0.2004), Ø5.6
Actual transformed model optical axis
D1
(44.4308,20.0817), Ø5.6
Actual model lens Ø5, despite smaller prior nominal assumption
CN mating faces are recessed relative to ordinary outer walls. Actual straight/right-angle cable overmolds, finger grip, insertion/removal paths, bending and simultaneous mating are NOT VERIFIED. Do not interpret connector visibility as proof a selected cable fits. Control travel, knobs and final footswitch load path likewise need detailed review.
Repair history and evidence
Initial R2 floor Z−8.3 intersected existing long LED model leads. Geometry repair cycle 1 addressed this single diagnosed LED-envelope cause without modifying components: floor lowered to−14.6, LED1 aperture centered on actual model axis, D1 aperture enlarged fromØ4.6 toØ5.6.
3D Model
and
3D Model
contain long lead local Y−25.4. Saved Rx90 and translations give LED1 minimumZ−10.0469 and D1 minimumZ−12.457. This gives floor gaps4.5531 and2.143 mm respectively. These are model-derived clearances, not measurements of assembled soldered parts. Prior project model-quality concerns remain unresolved.
Repaired base compiled as one solid, 125 ×78 ×37 mm, 60489.9625 mm³,122 faces. Repaired lid compiled as one solid,125 ×78 ×11.1 mm,23484.5775 mm³,52 faces. Reports flagged four base down-facing faces at foot pockets and nine lid down-facing faces in installed orientation. Print orientation review remains necessary; successful compilation does not validate overall fit.
Placement and verification
Base node cdced9b9-6e30-450e-b7bd-3485dbb414f3; lid node f4054034-e424-4bb6-a1ef-d52071365296. Both read back under ROOT, position0/0/0, rotation0/0/0, scale1, Z-up, enabled, physical materials and edges true. Asset references resolve to the repaired source storage paths above. Old base 1e58a379-0bc9-4371-ad55-899d63165218 and lid 39e022df-8aa8-4922-9e27-482dc95df7ae were disabled rather than deleted. Read-only layout inspection still reports100 ×60 mm board and73 placed components. No electronics edits were made by this executor; other active threads may independently alter electrical rules.
Table
Scoped item/check
Status
Evidence / blocker
Chamfered base/lid concept and seam
Completed
Compiled assets, closed/open renders
CN rim-open notches and lid completion tabs
Completed as concept
Source geometry and both side renders
Four foot pockets
Completed as concept
Source and underside render
Preserve PCB and component models
Completed within executor scope
No such mutations; read-only placement checks
LED floor repair
Completed
STEP-derived endpoints, new floor, underside inspection
Compute attachments unavailable and network recovery failed; global≥2 mm NOT VERIFIED
Final joints, hardware, positive retention, support-span compliance
Unattempted
Deliberately deferred until visual approval
Final STEP assembly inspection / physical testing
Unattempted
Concept stage; no manufacturing acceptance
Detailed-stage handoff
Proposed assembly: remove lid and panel hardware/knobs as required; lower board vertically with CN/J1 passing rim-open notches; secure PCB using qualified retention; lower lid over control/LED axes; secure lid; install panel hardware and knobs. The entire swept path and tooling access must be checked, not assumed.
Support seat centers use H2(−46.254,27.0335), H3(47.17,26), H4(−46.539,−26.05), H5(47,−26), actualØ2.2 NPTH. H1 is an electrical header, not a mounting hole. Current four annular seats are placeholders, not compliant final bosses. Long unsupported spans and footswitch loading require additional safe supports and final load-path design.
Hardware list: zero newly modeled hardware instances in this concept; six lid recesses are intent markers only. Final screws/inserts and PCB retention have not been selected, sized or installed. Keep hardware visible/separate when detailed CAD begins.
FDM intention: base open-side up; lid broad exterior face on bed, installed orientation stored separately. Foot-pocket bridges may need accessible support. Final enclosure material/nozzle/fit calibration are unresolved; older PETG recommendations and PLA knob-print records do not establish a newly approved enclosure profile. No sealing, thermal, strength, cable-fit or production-printability claim.
Lead should present these views and invite text feedback or a marked-up screenshot. No visual approval has yet been recorded; do not advance to detailed CAD.