MAX6575 Part Verification


Verify/repair ONLY active MAX6575LZUT+T UIDfc4a6a2d-fb25-4f0d-bc30-b2da8396dc4b ownerjharwinbarrozo URLhttps://www.flux.ai/jharwinbarrozo/max6575lzutplust~7fm initialb16af08f-a751-4cde-bf8e-2f3180c4debd. No children/anchor/placements/sharing/org edits. Official exact+T https://www.analog.com/en/products/max6575.html orderablerow; PDFhttps://www.analog.com/media/en/technical-documentation/data-sheets/max6575-max6575l.pdf evidence dsq_de685e68b8d2db840c51. Creation1VDD PowerIn,2GND Ground,3N.C. NotConnected,4TS0 Input,5TS1 Input,6I/O OpenCollector verify type bidirectional/open-drain behavior. Inspect actualpins/types/count1:1padmap global sizes/centers/pitch/span min gap nonoverlap topview pin1/silk body/modelnode intended parametric SOT (renderer omission not absent). Land/body query then secondfocused if missing; official external outline permitted. Verified recommendedpattern differing defaults => correct; no claims => explicitunqualified defaults. Identitygate before writes confirmedfixes only unchanged no republish. After fixes committed publish corrected EXISTING part newversion returnID. Compact complete report ownerUIDURLversion changedflags measurements evidencehandles allgaps; no production-ready claim.
I’ll verify the active part’s identity, pin mapping, and package geometry against Analog Devices documentation, then publish a new version only if confirmed corrections are needed.
Created a project doc

Part Verification

View Document

Part Verification Identity and publication
  • Owner: jharwinbarrozo; UID: fc4a6a2d-fb25-4f0d-bc30-b2da8396dc4b.
  • URL: /jharwinbarrozo/max6575lzutplust
  • Exact MPN: MAX6575LZUT+T. Official product-page scrape confirmed exact orderable row, 6-pin SOT23.
  • Initial published version supplied: b16af08f-a751-4cde-bf8e-2f3180c4debd.
  • Corrected EXISTING part published version: 10402417-9983-401c-b104-0f55340d3f4c.
  • Changed flags: body=true; mount=true; description=true; pin types=false; pin mapping=false; copper=false; silk=false; children/anchors/placements/sharing/org=false.
Verified pinout and actual mapping
Six terminals and six pads, one-to-one by matching terminal/pad UID. Pin table and trigger/output behavior verified by evidence dsq_cdc234650eff30b8e62...
Verified and corrected the existing MAX6575LZUT+T part, UID fc4a6a2d-fb25-4f0d-bc30-b2da8396dc4b, owned by jharwinbarrozo; published version 10402417-9983-401c-b104-0f55340d3f4c with corrected nominal body and mounting classification.
Six-pin mapping is verified; copper and silk remain unchanged, and lands remain unqualified defaults because official recommended-pattern dimensions could not be validated—no production-ready claim.
Full measurements, changed flags, evidence handles, and remaining gaps are in the project files: Part Verification.

Part Verification
Identity and publication
  • Owner: jharwinbarrozo; UID: fc4a6a2d-fb25-4f0d-bc30-b2da8396dc4b.
  • URL: /jharwinbarrozo/max6575lzutplust
  • Exact MPN: MAX6575LZUT+T. Official product-page scrape confirmed exact orderable row, 6-pin SOT23.
  • Initial published version supplied: b16af08f-a751-4cde-bf8e-2f3180c4debd.
  • Corrected EXISTING part published version: 10402417-9983-401c-b104-0f55340d3f4c.
  • Changed flags: body=true; mount=true; description=true; pin types=false; pin mapping=false; copper=false; silk=false; children/anchors/placements/sharing/org=false.
Verified pinout and actual mapping
Six terminals and six pads, one-to-one by matching terminal/pad UID. Pin table and trigger/output behavior verified by evidence dsq_cdc234650eff30b8e623 keys ds5–ds9 and ds2. Pin 3 may be open or grounded; pins 4/5 select timing.
Coordinates below are global footprint coordinates in mm, X right/Y up, as read from project data. All pads are Top rectangles, local size 0.70 x 1.00 mm, rotated 90/270 degrees, giving global X length 1.00 mm and Y width 0.70 mm.

Table


PinNameActual typePad/terminal UIDCenter X,Y mm
1VDDPower Ina49c6791-5076-46d0-8227-49a9a246488a-1.30,+0.95
2GNDGround9da4fb3d-34a9-4b39-b8e9-c49651a15ce1-1.30,0
3N.C.Not Connectedc6c1eae9-df20-4ecf-abea-8531fe191adf-1.30,-0.95
4TS0Input9804bf2e-81d9-4e2c-be61-bde9b20f6a7d+1.30,-0.95
5TS1Input44770290-1894-4cd6-bcbf-03f6e84a6caf+1.30,0
6I/OOpen Collector42916fd7-b154-4da0-bbf9-f2276cbeeed7+1.30,+0.95
I/O is bidirectional: it receives the trigger and subsequently sinks through an open-drain output; an external pullup is required. Retained Open Collector as the available ERC type representing the sink-only output; the descriptive text states the input behavior.
Top view matches the datasheet arrangement: 1/2/3 down left, 6/5/4 down right.
Geometry measurements and corrections
  • Nominal body corrected from 1.60 x 2.90 x 1.175 mm to 1.625 x 2.90 x 1.25 mm. Official U6-4 outline 21-0058 gives D 2.80/2.90/3.00 mm, E1 1.50/1.625/1.75 mm, A 0.90/1.25/1.45 mm (min/nom/max). Lead span E is 2.60/2.80/3.00 mm and pitch 0.95 mm BSC. Evidence dsq_e0822f502994d7487458 ds5–ds11.
  • Parametric SOT-23-6 Model node exists and inherits corrected body dimensions, position 0/0/0, rotation 0/0/0, unit scale. It is not an absent model merely because a renderer omits it. No claim of exact lead/model alignment or maximum-envelope qualification.
  • Source pad measurements unchanged: pitch 0.95 mm; row-center spacing 2.60 mm; copper outer X span 3.60 mm; inner X gap 1.60 mm; overall Y span 2.60 mm. Minimum same-row copper gap 0.25 mm. No rectangle overlap.
  • Existing silk lines: Y +/-1.65 mm, X +/-1.30 mm, stroke 0.15 mm. Minimum line-to-pad gap 0.275 mm. Pin-1 dot stored in SVG Y-down at (-2.088536,-1.65) mm, radius 0.2286 mm; conversion places it beside upper-left pin 1 in Y-up coordinates. Approximate minimum dot-to-copper gap 0.225 mm. No silk edits.
  • Mount corrected from Base to Surface Mount; verified in metadata readback.
Remaining gaps and qualification limits
  • Main datasheet maps U6-4 to outline 21-0058 and recommended land drawing 90-0175.
  • Land/body query then focused land query could not retrieve validated land dimensions. Alternate official path also failed to expose diagram dimensions; web scrape failed and direct PDF download returned HTTP 403. Search-only context suggested different lands, but that was not treated as source contents or mutation authority. Existing pads remain explicitly UNQUALIFIED DEFAULTS, not a verified manufacturer recommendation.
  • Maximum body/lead-envelope clearance, solderability, mask/paste details, and exact generated 3D lead geometry remain unqualified. Current parametric nominal height is not a maximum-height guarantee.
  • Mutation DRC validators returned no result (NOT CHECKED); no clean DRC/ERC claim.
  • No board placements, anchors, child projects, sharing, organization, or identity changes. No production-ready claim.
Next action
Obtain a readable official 90-0175 drawing, verify its actual diagram dimensions, then correct source pads if required and publish another version. Use maximum package dimensions for enclosure/clearance checks.
  • Identity and publication

  • Verified pinout and actual mapping

  • Geometry measurements and corrections

  • Remaining gaps and qualification limits

  • Next action