Only active personal part, confirm owner jharwinbarrozo, no children/duplicate/sharing/anchor edits. Original identity+numbered pins passed creation gate; inspect attached datasheet. Check symbol numbered names/types and actual pad mapping/pin1 topview/count/distinct/nonoverlap, measure geometry and compare source land pattern if available. Existing parametric model not missing/no asset; nominal model not maximum envelope. Inspect body/model fit, explicit skipped checks. Check Mount Surface Mount and repair confirmed defects only; publish changed existing sameUID new version. Return owner UID latest version full shortID URL, pin/pad count measurements and gaps. Unchanged published no republish.
I’ll inspect the existing part, attached datasheet, pin-to-pad mapping, footprint geometry, and model fit. I’ll repair only confirmed defects and publish a new version only if the part changes.
Verified the active personal LMV820ILT part only. Owner: jharwinbarrozo. Part UID: b0a0e4e7-9eeb-49e5-b96a-865d7f9c34ef. Project short ID: 5f9. URL: /jharwinbarrozo/lmv820ilt. No children, duplicates, sharing changes, or anchor edits.
Symbol and mapping
All six numbered terminal names and electrical types match their functions: 1 IN+ (Input), 2 VCC− (Power In), 3 IN− (Input), 4 OUT (Output), 5 SHDN (Input), 6 VCC+ (Power In). Datasheet pinout is top view, pin 1 upper left.
Pad UID equals its corresponding terminal element UID in the inspected data. All six pads are active, distinct and on Top, with no duplicate numbers. Positions below are millimeters in footprint Cartesian coordin...
Verified LMV820ILT, owner jharwinbarrozo, short ID 5f9; corrected missing Mount = Surface Mount and republished the same UID b0a0e4e7-9eeb-49e5-b96a-865d7f9c34ef, latest version 00b53dbb-aea4-42f2-b74d-0c3337266187.
All 6 pins / 6 distinct pads map correctly, including top-view pin 1; pads measure 1.00 × 0.70 mm, pitch 0.95 mm, row separation 2.60 mm, minimum copper gap 0.25 mm, with no overlap.
The existing nominal parametric model was preserved; manufacturer land-pattern certification and detailed 3D fit remain unverified, with measurements and skipped checks recorded in the Part Verification project file; no children, duplicates, sharing, or anchor edits were made.
Verified the active personal LMV820ILT part only. Owner: jharwinbarrozo. Part UID: b0a0e4e7-9eeb-49e5-b96a-865d7f9c34ef. Project short ID: 5f9. URL: /jharwinbarrozo/lmv820ilt. No children, duplicates, sharing changes, or anchor edits.
Symbol and mapping
All six numbered terminal names and electrical types match their functions: 1 IN+ (Input), 2 VCC− (Power In), 3 IN− (Input), 4 OUT (Output), 5 SHDN (Input), 6 VCC+ (Power In). Datasheet pinout is top view, pin 1 upper left.
Pad UID equals its corresponding terminal element UID in the inspected data. All six pads are active, distinct and on Top, with no duplicate numbers. Positions below are millimeters in footprint Cartesian coordinates (+Y up):
Table
Pin
Name
X
Y
1
IN+
-1.30
0.95
2
VCC−
-1.30
0
3
IN−
-1.30
-0.95
4
OUT
1.30
-0.95
5
SHDN
1.30
0
6
VCC+
1.30
0.95
The rendered top view places the silk pin-1 dot at the upper-left pad. The negative-Y circle coordinate in the silk SVG uses the asset's flipped graphic coordinate convention; it is not evidence of a pin-1 error.
Measured footprint
Six rectangular pads each have local dimensions 0.70 × 1.00 mm, rotated ±90°, giving board-axis dimensions 1.00 × 0.70 mm. Pitch: 0.95 mm. Row center separation: 2.60 mm. Adjacent same-row edge gap: 0.25 mm. Opposite-row inner gap: 1.60 mm. Overall copper extent: 3.60 × 2.60 mm. All pads are non-overlapping; no holes are defined.
The datasheet specifies package lead pitch e = 0.95 mm typical; the measured pad pitch agrees. No authoritative PCB land-pattern dimensions were recovered by the datasheet query; absence of a land pattern is itself unverified. Consequently pad length, width, row separation, solder fillet allowance, mask/paste design and reflow suitability are NOT certified against a manufacturer land pattern. Existing pad geometry was preserved rather than changed on an unsupported assumption.
Body and model
An existing active parametric SOT-23-6 Model node is present; no imported model asset is required to establish that presence. Configured package size is 1.60 × 2.90 × 1.175 mm, at origin with zero rotation and unit scale. The datasheet package ranges are E = 1.50–1.75 mm, D = 2.80–3.05 mm, A = 0.90–1.45 mm, H = 2.60–3.00 mm and lead width b = 0.35–0.50 mm. Configured body values are within those ranges. This is a nominal parametric representation, NOT a maximum-clearance envelope. Footprint inner pad edges at X = ±0.80 mm coincide with the nominal body side planes.
The render service returned 0 asset-backed model nodes and rendered copper/silk only. Detailed generated lead geometry, lead-to-pad contact, body standoff, mesh pin-1 marking and full 3D collision fit could not be visually verified. This limitation does not mean the parametric model is missing. No model replacement or relocation was made.
Repair and checks
Confirmed missing Mount metadata was set to Surface Mount and read back successfully. No electrical, numbered-pin, pad-mapping or geometric defect was confirmed. Part checks show Missing Properties, Missing Terminals and Excluded Terminal success. Pin Group, Pin Orientation and Section are informationally unset on the six terminals; these were not changed without evidence of a functional defect. Requested overlapping-copper/invalid-pad checks returned no separate DRC review entries; non-overlap was therefore established from coordinates, not a claimed DRC success.
A new version of this same existing UID will be published for the Mount correction. The previous published version was 74f083b6-c53f-4f4c-b21d-8d06dc656578. Consult part version history for the resulting latest version.