LMV118MFX/NOPB Verification


Verify LMV118MFX/NOPB
Only active personal part project; no children. Confirm owner jharwinbarrozo before edits. Original identity/pinout checked before creation; use current attached datasheet plus query as needed. Inspect symbol names/types/numbers and actual pads mapping/top-view pin1, distinct count/nonoverlap, measure size/pitch/row span, existing parametric body/model fit. SOT23-6 actual package required. Defaults are not qualified manufacturer lands without evidence; nominal parametric model exists and is not max envelope. Check Mount is Surface Mount, correct only confirmed errors. No duplicate/sharing/anchor changes. Return final owner/UID/latest published version/full shortID URL, sourced vs measured geometry, explicit all incomplete checks.
After fixes committed publish new version of existing same-UID part and give ID. No republish unchanged already published part.
I’ll verify ownership, pin mapping, footprint dimensions, and the existing package model against the attached datasheet, then correct only confirmed errors.
Created a project doc

Part Verification

View Document

Part Verification Identity and scope
  • Part: LMV118MFX/NOPB, existing same-UID personal part; owner jharwinbarrozo confirmed before edits.
  • UID: d567c1ff-3728-452c-b3db-8d6dc9e555f7.
  • Full project URL: /jharwinbarrozo/lmv118mfxnopb
  • Exact MPN uses six-pin SOT-23 DBV, not the five-pin LMV116 variant.
  • Only confirmed correction: Mount changed from Base to Surface Mount, commit d0fd5c1d; read-back confirmed. No pin, geometry, anchor, sharing, or duplicate-part changes.
Pin and actual pad mapping
Datasheet pin definitions match all six saved terminal names, numbers, and electrical types; SD is active-high shutdown.
Verified LMV118MFX/NOPB, owned by jharwinbarrozo, and corrected Mount → Surface Mount; six pin mappings and distinct, nonoverlapping pads passed inspection. Same UID: d567c1ff-3728-452c-b3db-8d6dc9e555f7; new published version: 720b9d86-18f0-4faa-b1ce-ed4d8a75f0cb.
The Part Verification project file records sourced versus measured geometry and all incomplete checks, including land-width qualification, rendered symbol appearance, and 3D model fit/seating.

Part Verification
Identity and scope
  • Part: LMV118MFX/NOPB, existing same-UID personal part; owner jharwinbarrozo confirmed before edits.
  • UID: d567c1ff-3728-452c-b3db-8d6dc9e555f7.
  • Full project URL: /jharwinbarrozo/lmv118mfxnopb
  • Exact MPN uses six-pin SOT-23 DBV, not the five-pin LMV116 variant.
  • Only confirmed correction: Mount changed from Base to Surface Mount, commit d0fd5c1d; read-back confirmed. No pin, geometry, anchor, sharing, or duplicate-part changes.
Pin and actual pad mapping
Datasheet pin definitions match all six saved terminal names, numbers, and electrical types; SD is active-high shutdown. The datasheet presents the DBV pinout in top view.
Measured computed node positions are in mm in the Y-up scene, footprint rotation zero, top side. Terminal UIDs are the actual corresponding pad UIDs, so mapping is direct rather than inferred from labels alone.

Table


NumberNameSaved typeXY
1OUTPUTOutput-1.30+0.95
2V−Power In-1.300
3+INInput-1.30-0.95
4−INInput+1.30-0.95
5SDInput+1.300
6V+Power In+1.30+0.95
Measured numbering runs counterclockwise in top view, with pad 1 at (-X,+Y). The rendered footprint silk dot is at the upper-left beside pad 1; SVG silk Y is inverted relative to computed node Y. Six unique pad UIDs and six distinct centers are present, with no duplicate or overlapping pad rectangles.
Sourced versus measured geometry
Datasheet DBV0006A evidence: body length 2.75–3.05 mm; overall height 0.90–1.45 mm; lead-tip span 2.6–3.0 mm; pitch 0.95 mm; lead width 0.25–0.50 mm; stated standoff 0.00–0.15 mm. These are package dimensions, not copper-land sizes. The example land drawing supports pad length 1.1 mm and opposing pad-column center spacing 2.6 mm.

Table


FeatureMeasured current projectQualification
Actual package generatorSOT-23-6Matches six-pin package identity
Pad count6 distinct top-side rectanglesVerified from actual pad nodes
Copper size after rotation1.10 mm X × 0.60 mm Y1.10 length sourced; 0.60 width not independently qualified from available parsed diagram endpoints
Same-row pitch0.95 mmMatches sourced pitch
Opposing row center span2.60 mmMatches example land drawing
Copper outer extents3.70 mm X × 2.50 mm YCalculated from computed centers, sizes and rotations
Same-row copper gap0.35 mmCalculated: 0.95−0.60; no overlaps
Opposing-row inner gap1.50 mmCalculated: 2.60−1.10; no overlaps
Parametric package size1.60 mm X × 2.90 mm Y × 1.175 mm ZExisting nominal generator data; not a maximum envelope
Model transformPosition 0, rotation 0, scale 1; under footprintVerified node structure only
Checks and explicit incomplete items
  • Metadata, required properties, terminal presence and copper representation checks succeeded.
  • Missing Parametric Symbol Properties is informational, not an error: Pin Group, Pin Orientation and Section are absent for all six terminals.
  • Saved pin names/types/numbers were inspected, but the schematic image tool returned a blank image; complete rendered symbol appearance/readability remains unverified.
  • Manufacturer land width 0.60 mm remains unqualified: two focused datasheet queries did not establish dimension-line endpoints. No unsupported footprint edits were made.
  • Body-only width and detailed package standoff interpretation remain unqualified from the available parsed diagram evidence. Do not treat the measured 1.60 mm nominal model width as sourced exact mechanical data.
  • Existing parametric Model node has no uploaded custom model asset. The 3D read-back returned 0 of 0 model nodes and rendered pads/silk only. Therefore actual model body size, lead geometry/fit, pin-1 feature, seating plane and orientation are not visually verified. Presence of the node is not proof of a rendered qualified model.
  • Nominal 1.175 mm height is not the 1.45 mm maximum mechanical clearance envelope; maximum body/lead tolerances and assembly courtyard are not qualified.
  • Requested overlap/invalid-pad reviews returned no separate review entries; nonoverlap conclusion is from explicit pad geometry, not a claimed DRC success.
  • No fabrication, solder-paste/mask process qualification, exported manufacturing-file check, physical sample test or imported-instance test was performed.
Publication
Publish only the Mount metadata correction to the existing UID after this audit record is saved. Record the new published version ID in the completion response; no unchanged-part republish was performed.
  • Identity and scope

  • Pin and actual pad mapping

  • Sourced versus measured geometry

  • Checks and explicit incomplete items