Light Pipe Design


Created a parametric set of four individual clear-PETG light pipes, aligned with the existing lid holes and LEDs.

3D Model

; detailed parameters are in Light Pipe Insert.
Open items
  • The Ø2.85 mm stems have a tight provisional friction fit in the Ø3.0 mm holes.
  • Physical fit, brightness, and optical crosstalk require a test print.
Recommended next steps
  1. Print caps-down in transparent PETG with supports disabled and a removable 3–5 mm brim.
  2. Use solid infill, slow external walls, and verify that the slicer shows four separate parts.
  3. Test one pipe first; lightly sand or polish the optical ends if needed.

Enclosure Base Render Repair
Scope result
  • Completed — asset/node inspection: Inspected project non-model and model assets and the full model/layout/root node inventory (74 nodes). There is one root enclosure base model and one root lid model; no duplicate base model nodes were found.
  • Completed — failure diagnosis: The enabled base node referenced enclosure-base-integral-clips-retry.build123d, but that asset had been deleted. Before repair the node had neither computed.storageName nor computed.url. Its root parent, position, rotation, scale and visibility flags were already correct; no evidence indicated a placement or conversion failure.
  • Completed — durable source restoration: Recovered the exact original clip-enabled source from historical asset metadata at commit 855fb0c9; restored it under the exact same asset name. No new clip geometry was invented, no source geometry changed, and no project-wide revert was performed.
  • Completed — connected-solid validation: Real upload conversion reports 1 solid, 163 faces, 119 × 107 × 30.5 mm overall (width includes wall-mount ears), volume 57488.7486 mm³. Source explicitly fuses both left/right complete clips to the shell and rejects disconnected or invalid geometry. It also includes seated narrow-PCB slab collision checks and connector-window keep-open checks. Conversion succeeded with these checks intact.
  • Completed — active model resolution: Read-only scene-tree inspection after restoration confirms the existing enabled root base node now resolves to the restored asset and a GLB model URL.
  • Unattempted — duplicate removal: Not required; no duplicate base nodes found. Other assets/nodes were preserved.
  • Failed/blocked — assembled visual verification: Two attempts to open/focus PCB 3D returned exactly The requester frontend session was not found. An asset-only rendered preview was available and showed the enclosure shell and a visible clip, but it is not an assembled PCB view and does not prove both clips are visibly unobstructed in that assembly. Do not mark the full visual done criterion complete until the live browser assembly is inspected. The restored base remains active; no lid/PCB positions or other prior state were changed.
Active node read-back

Table


FieldValue
NameWall Enclosure Base — PETG
UIDe1624f1e-3622-4d57-a788-d32b786cb9e0
ParentROOT
Asset ruleenclosure-base-integral-clips-retry.build123d
Resolved storage namedocument_assets/enclosure-base-integral-clips-retry-c54ffc59-b43a-4bdc-a117-515c02014050.build123d
Position XYZ45 mm, -50 mm, 0 mm
Rotation XYZ0°, 0°, 0°
Computed 3D scale XYZ1, 1, 1
Computed activetrue
Z-up / visible edges / physical materialstrue / true / true
Source finishGray plastic, Color('#9a9a9a')
Resolved model URL:

3D Model

3D Model

The lid remains separately enabled under ROOT at (45, -50, 72.7263) mm, rotation (0,0,0), in its existing exploded display position. Base source retains its original shared frame: floor bottom -12 mm, PCB underside -1.5 mm and seam +18.5 mm. Existing lower bosses correspond to M3/M4 positions after the unchanged XY translation.
Remaining limitations
The conversion report flags 11 down-facing planar faces, 339.9766 mm² total, that may need print supports; source already specifies removable supports under elevated beams and window-roof support/bridge qualification. This repair is restoration and render-reference validation, not new manufacturing or clip-fatigue qualification. Final live assembled visual inspection is still required to confirm base body and both clips around the PCB at correct scale/location.