EEPROM Land Pattern Correction


Targeted confirmed land-pattern correction
Existing 25AA010AT-I/OT UID a88d1cce-c15c-4487-a99c-a9571d16202b owner jharwinbarrozo. Independent review query dsq_5cde3ff42b15ff35c3c5 ds3-ds9 verified manufacturer recommended lands: pitch E=.95mm row span C=2.80mm tangential pad width X=.60mm radial length Y=1.10mm G1.70 GX.35 Z3.90. Current default row2.6 pad.7x1.0 confirmed mismatch. Correct SAME existing footprint pads via local axis-aware rules to specified values; preserve topview pin1 and all terminal mapping. Do NOT create new part UID. Inspect exact identity first. Preserve body/model unless necessary to align footprint, keep parametric model. Add note exact full orderable applicability remains unresolved despite precise supplier listing; no production approval. Check all6 distinct/nonoverlap and exact final computed pad/pitch/span. After committed publish new version SAME UID and return new version, computed geometry, changed properties and unchanged numbered map. No children or other projects.
I’ll confirm the existing part identity, correct its six pads in place, then verify the geometry and publish a new version under the same UID. I’ll preserve the pin mapping and parametric model, and record that orderable applicability remains unresolved.
Created a project doc

Land Pattern Correction

View Document

Land Pattern Correction Identity and scope
Existing project: 25AA010AT-I/OT, owner jharwinbarrozo. Existing published part UID: a88d1cce-c15c-4487-a99c-a9571d16202b. All six original pad nodes were edited in place; no new part or replacement footprint was created.
Applicability warning
Exact full orderable applicability remains unresolved despite the precise supplier listing. This geometry correction does not constitute production approval. Confirm the exact manufacturer's full orderable package applicability before production use.
Requested target and computed result
The correction brief supplied independently reviewed land-pattern targets, with evidence handle dsq_5cde3ff42b15ff35c3c5, keys ds3–ds9. That external review's citation payload was not re-expanded here...
Corrected and republished the same part UID a88d1cce-c15c-4487-a99c-a9571d16202b, new version a0e350e6-2ae0-4799-a814-2176b25848e1: pads 0.60 × 1.10 mm, pitch 0.95 mm, row span 2.80 mm, G/GX/Z 1.70/0.35/3.90 mm, with all six pads distinct and nonoverlapping. Preserved the parametric model and numbered map 1 SCK, 2 VSS, 3 SI, 4 SO, 5 CS, 6 VCC; changed properties and verification are recorded in project files: Land Pattern Correction. Exact orderable applicability remains unresolved—no production approval; automated DRC returned no result.

Land Pattern Correction
Identity and scope
Existing project: 25AA010AT-I/OT, owner jharwinbarrozo. Existing published part UID: a88d1cce-c15c-4487-a99c-a9571d16202b. All six original pad nodes were edited in place; no new part or replacement footprint was created.
Applicability warning
Exact full orderable applicability remains unresolved despite the precise supplier listing. This geometry correction does not constitute production approval. Confirm the exact manufacturer's full orderable package applicability before production use.
Requested target and computed result
The correction brief supplied independently reviewed land-pattern targets, with evidence handle dsq_5cde3ff42b15ff35c3c5, keys ds3–ds9. That external review's citation payload was not re-expanded here; manufacturer provenance is not independently revalidated in this correction record. The following values are verified against the final computed Flux geometry, not a new datasheet assertion.

Table


QuantityFinal computed geometry (mm)
Local pad X, tangential width0.60
Local pad Y, radial length1.10
Pad pitch E0.95
Row-center span C2.80
Inner row gap G = C − radial length1.70
Adjacent same-row gap GX = E − tangential width0.35
Outer copper span Z = C + radial length3.90
Existing pad rotations are retained: left row 270°, right row 90°. Thus the footprint-axis copper dimensions are 1.10 mm X by 0.60 mm Y. Centers are X = ±1.40 mm and Y = −0.95, 0, +0.95 mm. All six centers are distinct. All 15 pad pairs are nonoverlapping: six same-row pairs have at least 0.35 mm vertical edge separation; all nine cross-row pairs have 1.70 mm horizontal separation.
Changes
  • All six pads: local size set to 0.60mm 1.10mm (previous computed size 0.70 × 1.00 mm).
  • SO, CS, VCC: local positionX set to 1.40mm (previous +1.30 mm).
  • SI, VSS, SCK: local positionX set to -1.40mm (previous −1.30 mm).
  • Existing Y positions, rotations, terminal UIDs, numbering, symbol, footprint UID, body dimensions, silk, and parametric model retained unchanged. Parametric body remains 1.60 × 2.90 × 1.175 mm.
Unchanged numbered map
Coordinates below are final Flux footprint coordinates, in millimeters. Top-view pin-1 convention was preserved, not reoriented.

Table


NumberTerminalXY
1SCK−1.40+0.95
2VSS−1.400
3SI−1.40−0.95
4SO+1.40−0.95
5CS+1.400
6VCC+1.40+0.95
Verification limits
Final node-tree read confirms computed pad geometry and unchanged model/body. Automatic post-edit DRC validators returned no result; no clean automated DRC result is claimed. The distinctness and nonoverlap verdict above is a direct rectangular-geometry check.
  • Identity and scope

  • Applicability warning

  • Requested target and computed result

  • Changes

  • Unchanged numbered map