Generate and Orient CAD Model


Created a project doc

CAD completion status

View Document

CAD completion status
Created datasheet-based parametric

3D Model

. New model node UID 1e189203-0e34-4eda-b6d0-b7b0c134ccbd is directly under ROOT, outside footprint, with asset linkage. Build report states orientation/seating read-back completed and schematic/footprint preserved. See Package Model for drawing dimensions and rules.
Remaining fit issue
Build verification reports datasheet lead-circle diameter 5.08 mm versus footprint pad-circle diameter 5.84 mm, resulting in 0.380 mm radial misalignment for each lead. Rigid rotation/translation cannot resolve this. Do not scale the authentic model merely to hide the m...
Created the

3D Model

Design view of CAD completion status
, linked it to a new model node directly under root, and oriented it to the footprint without changing the footprint or schematic.
Fit remains unresolved: the datasheet’s 5.08 mm lead circle differs from the footprint’s 5.84 mm pad circle, leaving each lead 0.38 mm off-center; rotation cannot fix this. I saved the findings and remaining verification work in CAD Completion Status.
Execution stopped because your ACUs ran out.

Waiting for input


CAD completion status
Created datasheet-based parametric

3D Model

Design view of CAD completion status
. New model node UID 1e189203-0e34-4eda-b6d0-b7b0c134ccbd is directly under ROOT, outside footprint, with asset linkage. Build report states orientation/seating read-back completed and schematic/footprint preserved. See Package Model for drawing dimensions and rules.
Remaining fit issue
Build verification reports datasheet lead-circle diameter 5.08 mm versus footprint pad-circle diameter 5.84 mm, resulting in 0.380 mm radial misalignment for each lead. Rigid rotation/translation cannot resolve this. Do not scale the authentic model merely to hide the mismatch. Footprint correction or intentionally formed-lead modeling requires a design decision; neither was attempted.
Resume
Independent read-only fit review was dispatched at /jecstronic/lm318h and a completion notification arrived, but its report was not collected before the ACU limit ended execution. Retrieve that report before making a correction. Confirm root placement, asset resolution, drawing dimensions, scale, seating, pin-1 orientation and numerical lead/pad registration. Resolve the circle mismatch with user approval if footprint changes or lead forming are needed.
Execution stopped because account ACUs ran out. Model creation is complete; full footprint fit is not declared complete.
  • Remaining fit issue

  • Resume