What it is forThis is an isolated 6 W DC-DC converter module that takes a 24 V nominal input and generates dual regulated outputs of +15 V and -15 V, rated at 200 mA per rail.
+15 V / -15 VTable
| Parameter | Value |
|---|---|
| Input range | 18 V to 36 VDC |
| Nominal input family | 24 VDC |
| Outputs | +15 V / -15 V |
| Output current | ±200 mA |
| Power | 6 W |
| Efficiency | 84% |
| Isolation | 1.5 kVDC input-to-output |
| Optional high-isolation version | 3.0 kVDC with -H suffix |
| Operating temperature | -40°C to +90°C |
| Full power to | +65°C |
| Package | SIP-8 |
| Ripple and noise | 75 mV pk-pk |
| Regulation | Line reg ±0.2%, load reg ±1% |
| Protection | Continuous short-circuit protection with auto recovery |
18-36 V input -> internal high-frequency conversion + transformer isolation -> regulated +15 V / common / -15 V outputs-Vin+VinRemote On/Off+VoutCommon-VoutCase+Vin and -Vin+Vout, Common, and -Vout-R optionC1 = 10 µF / 50 VL = 10 µHC4 and C5 = 220 pF / 3 kV
with the note that these parts should be placed as close as possible to the module.Table
| Variation | Options |
|---|---|
| Input family | 5 V nominal, 12 V nominal, 24 V nominal, 48 V nominal |
| Actual input ranges | 4.5-9 V, 9-18 V, 18-36 V, 36-75 V |
| Single outputs | 3.3 V, 5 V, 12 V, 15 V, 24 V |
| Dual outputs | ±5 V, ±12 V, ±15 V |
| Isolation option | Standard 1.5 kVDC, optional 3.0 kVDC (-H) |
| Remote option | -R suffix |
Typical use cases by family member
| Model type | Best suited for |
|---|---|
| Single-output 3.3 V / 5 V | Isolated logic rails, digital subsystems, comms interfaces |
| Single-output 12 V / 15 V / 24 V | Isolated actuator, relay, or analog supply rails |
| Dual-output ±5 V | Lower-voltage analog and interface circuits |
| Dual-output ±12 V | General analog and industrial signal conditioning |
| Dual-output ±15 V | Precision analog, op-amps, instrumentation, older industrial analog standards |
To get started, talk to Flux or create a New Document.