I’ve updated the target to just right of U5, on the top side, facing out through the enclosure side wall. I saved and measured your STEP file, but no USB-C connector, wiring, or enclosure cutout has been added yet.
I found two important constraints:
  • J1 pin 1 connects to the buck-regulator output, so USB power cannot safely connect there directly without reverse-current isolation. Pins 2–4 provide ground and the two existing 5.1 kΩ CC-resistor connections.
  • The enclosure’s outer wall is 4.5 mm beyond the PCB edge. Connector reach and cable clearance need checking, along with U5’s antenna clearance.
Next steps are to finalize the protected charging circuit, verify the connector beside U5, then create the aligned enclosure opening. Execution stopped because your ACUs ran out.
"USB-C Charging Circuit Design" completed.
The charging-circuit task is marked complete, but I haven’t reviewed its results or verified any project changes. The USB-C placement beside U5 and the enclosure opening remain unconfirmed.
Execution remains stopped because your ACUs ran out.

Enclosure Geometry Inspection
Scope and status
Geometry-only inspection dated 2026-10-23. The latest instruction supersedes the original top-left request: investigate a top-side USB-C receptacle just right of U5, with its mouth facing the enclosure side wall. Do not recenter the PCB, cut the enclosure, or mutate board placement. Connector model selection is being handled separately.
Partial inspection only; not a fit approval. Execution stopped when ACUs ran out. No PCB components, outline, wiring, or enclosure geometry were changed. The original STEP was stored as a project asset; no enclosure model node was placed.

Table


Assigned itemStatusEvidence / remaining issue
Preserve unchanged original STEPCompletedSource-URL asset import succeeded; subsequent full asset listing confirmed the stored original.
Measure STEPCompleted for overall geometry and identified featuresNative imported-CAD measurement returned one valid solid and dimensions below. Local sections still needed.
Read board outline, thickness, mounting positionsCompleted for outline, reported stackup and mounting-component originsLayout tree and partial 2D inspection agree on the frame. Actual M1/M2 drill geometry remains unverified.
Establish XY alignmentCompleted as a nominal alignment proposalTwo enclosure post centers match the existing mounting-component origins to under 0.004 mm without rotation.
Verify full 3D alignment, interference and component heightsUnattemptedNo placed-model/assembly inspection or overlap calculation was run.
Inspect U5 antenna connection and RF keepoutUnattemptedU5 geometry and the two layout keepouts remained on later pages when execution stopped. Datasheet and connectivity not inspected.
Exact USB-C placement, maximum envelope and wall openingUnattempted as a final designOnly a provisional study location is given below. Requires selected connector, RF constraints, complete layout and 3D clearance inspection.
Cut enclosure or mutate boardUnattempted, intentionallyExplicitly outside scope.
Original asset

3D Model

  • Project asset name: virtus_v2_base.step
  • Asset UID: 306dcc78-7a82-427a-9735-f67d8c67b327
  • Storage key: document_assets/virtus_v2_base-f6c5573a-5a25-46a5-8c6e-91648640c160.step
  • Original attachment:

    3D Model

  • Imported from the original URL without editing or conversion. Byte-hash comparison was not run.
  • Native run_imported_cad(action=measure) reported valid=true, solids=1, part s1, name Open CASCADE STEP translator 7.7 1, volume 94,565.4504 mm³.
Coordinate systems and board measurements
All dimensions are in millimeters. Canonical top view is +X right, +Y up, viewed from the component/top side. The board was not recentered.
  • Layout UID: 4f8d7b61-3353-4220-a327-aedcb6b47f63.defaultlayout
  • Existing layout translation relative to ROOT: (-5.0689, +3.5538); Z rotation 0°.
  • Layout-local rectangular outline, confirmed by the 2D polygon: X [-42, +42], Y [-25, +25], 84 × 50.
  • ROOT outline: X [-47.0689, +36.9311], Y [-21.4462, +28.5538].
  • Top-left local corner: (-42,+25), ROOT (-47.0689,+28.5538). This is no longer the requested USB-C location.
  • Stackup: 4 Layer Custom; tool-reported total thickness 1.30 mm. Manufacturing thickness/tolerance was not independently checked.
  • Local-to-ROOT mapping: Xroot = Xlocal - 5.0689, Yroot = Ylocal + 3.5538.
Mounting alignment evidence

Table


FeaturePCB layout-local originEnclosure STEP post/hole centerDirect XY mismatch
M1(37.0729,14.9996)(37.07,15.00)≈0.00293
M2(-37.3229,-21.1483)(-37.32,-21.15)≈0.00336
Both matches support identity XY mapping from STEP to layout-local coordinates, with no rotation. The tiny differences are consistent with rounding enclosure coordinates to 0.01 mm; they are not manufacturing tolerance evidence. A STEP model in ROOT would therefore nominally use XY translation (-5.0689,+3.5538), not (0,0).
The STEP post seating faces are at Z=40. If the PCB underside sits on those faces without spacers, PCB top is nominally STEP Z=41.30. This is an assembly assumption, not a verified installed transform. The native Flux PCB Z datum was not read, so no final model-node Z translation is specified.
Warning: M1/M2 are named M3 Mounting Hole, but the partial 2D output showed only 2 × 2 placeholder rectangles and no drill circles for these components. Their true drill diameters and usable mounting-hole implementation require inspection; do not treat the part name as drill verification.
STEP dimensions

Table


FeatureMeasurement / locationEvidence and interpretation
Overall bounds, including exterior feet/flangesX [-69.5,69.5], Y [-29.5,29.5], Z [0,61.1]Native solid bounds: 139 × 59 × 61.1
Main end-wall outer planesX=±56.5Main body length between planes 113; exterior feet extend beyond this
Main side-wall outer planesY=±29.5Main body width 59
Main cavity wall planesX=±54, Y=±27Nominal central cavity 108 × 54, locally reduced by bosses
Side and end wall thickness2.5Outer-to-inner plane separation
FloorBottom Z=0, interior Z=3Nominal 3 mm floor
Main rimZ=61.1Open-top rim; no lid supplied or authored
Central floor-to-rim height58.161.1−3; corner features reduce usable space locally
PCB support postsCenters (-37.32,-21.15) and (37.07,15)Ø7, cylinder spans Z=3…40
PCB support boresSame centersØ4, Z=32…40, nominal depth 8
PCB support height above floor3740−3
Corner internal featuresCylindrical surfaces centered (±46.5,±19.5), radius 2.5Z=3…59.6; not necessarily complete isolated circular posts
Corner boresCenters (±49,±22)Ø5.6, Z=45.6…59.6
Outer corner cylindrical surfacesCenters (±52,±25), radius 4.5Z=2.8…61.1
Upper corner holesCenters (±52,±25)Ø4, Z=59.6…61.1
External foot mounting holesCenters (±63,±17)Ø5.5 through Z=0…4
The native measurement reports many opposing planes as possible “walls”; only geometrically identified wall pairs are interpreted above. Likewise, automatic opening summaries sometimes use face centroids rather than individual opening centers; use cylinder/face geometry and targeted sections for final cutouts.
Existing side-wall penetrations relevant to orientation
  • −Y wall: large circular opening center approximately (X=-20,Z=17), Ø21.34; four Ø3.18 holes at X=-30.72/-9.28, Z=6.28/27.72; another Ø6.5 hole near (X=38,Z=9).
  • +Y wall: large circular opening center (X=-22,Z=17), Ø21.34; four Ø3.18 holes at X=-32.72/-11.28, Z=6.28/27.72.
  • +Y wall also contains a small existing rounded-opening/recess system around (X=20,Z=17). Measured face limits include X=10.2…29.8 and Z=14.1…19.9 for the larger inner recess, plus smaller rounded features. Do not assume this is suitable for the proposed PCB-mounted receptacle: it is well below the inferred PCB top at Z=41.30, and its full profile was not sectioned.
Board-to-cavity nominal margins
With identity XY alignment, a centered rectangular 84 × 50 board has 12 mm from each short end to the X=±54 cavity planes and 2 mm from either long board edge to the Y=±27 cavity planes. These are plane-to-outline values, not minimum distances to corner bosses or other solids.
Under the seating assumption, PCB top to the rim is 19.80 mm. A lid, sealing lip, screw head, component height, and tolerances can reduce this; none were included in a clearance approval.
Provisional USB-C study location — not a placement approval
The user's revised request is interpreted as a receptacle on the top PCB face, to the +X/right of U5, facing +Y through the long enclosure wall. A +X-facing receptacle immediately right of U5 would not naturally reach the distant X=54 cavity end wall; the +Y edge is the geometrically natural interpretation. Confirm the intended wall only if this interpretation differs from the user's view.
For follow-up inspection, use the provisional mouth centerline Xlocal=10.0, facing +Y:

Table


Reference locationLayout-local / STEP XYROOT XY
PCB top-edge centerline point(10.0,25.0)(4.9311,28.5538)
Inner wall intersection(10.0,27.0)(4.9311,30.5538)
Outer wall intersection(10.0,29.5)(4.9311,33.0538)
This gives numerical follow-up coordinates, not an exact component origin, final mouth position, or opening size. Board edge to outside wall is 4.5 mm: 2 mm cavity gap plus 2.5 mm wall. The selected receptacle's setback/overhang, plug nose engagement and cable overmold determine whether a recess or modified wall is required. Do not assume a standard edge-mounted connector will be externally accessible through this depth.
A nominal study window X=4…16, Y=16.5…25 (12 × 8.5 mm on-board) can be examined first. It is not a proven free-space envelope or maximum connector size. U5's actual transformed body and keepouts, routed copper/vias, shell anchors, pin lands and tool access have not been checked against it. Final mouth height would be STEP Z=41.30 + h, where h comes from the selected connector's verified mechanical drawing. No numerical value for h or cutout width/height was guessed.
Nearby geometry already read
  • U5 is locked, with layout-local origin (-1.7027,14.9621). The component-bounds summary gives width 11.1 and height 15.2, but its placement origin is not necessarily its body center; therefore no exact U5 edge or RF clearance is inferred from that summary.
  • R11 origin (5.5609,13.5696); the 2D pad/body geometry places its highest physical Y extent around 14.0921. Its designator text extends to approximately Y=15.601.
  • SW2 origin (9.4989,10.4896). Body reaches approximately Y=12.13; its remote designator text occupies roughly Y=14.952…16.187. Silkscreen text is not a physical obstruction but may need relocation later.
  • C15 origin (4.5968,10.7446), rotation 270°; physical upper extent approximately Y=11.9696.
  • First test point RST is centered (19.84,14.7696) with Ø1.8 copper. DIO/CLK/3.3V/GND continue farther right.
  • M1/enclosure post center (37.07,15) is well to the right of the study centerline. Exact connector/cable-to-post clearance is not calculated without an envelope.
  • B1 is a bottom-side battery holder, BK-18650-PC2. Its 2D body is about 76.96 × 20.98 at local origin (-2.7603,-0.1491); it does not occupy the proposed top-edge strip in XY, but installed height, battery and cable clearance were not inspected.
Warning — RF: U5 part identification, antenna connection, antenna orientation, manufacturer's metal/ground keepout and the two existing layout keepouts are still unverified. A USB shell and inserted cable beside U5 can alter RF behavior even with no mechanical collision. Do not approve or place the connector until this is checked.
Verification performed and resume checklist
Read-only checks completed after asset import:
  1. Full stored-asset listing confirmed the original STEP asset handle and durable URL.
  2. Native imported-CAD measurement validated the solid and returned planes, cylinders, bores and dimensions.
  3. Layout tree read supplied unchanged board position, stackup and all component origins.
  4. Partial 2D layout read independently confirmed the rectangular outline and selected neighboring pads/body geometry.
No ERC/DRC was run because no electrical/layout mutation was made. No assembly overlap volume, minimum 3D clearance, mounting-hole drill verification or final connector fit result is available.
To resume:
  1. Read U5's complete 2D footprint and model, its exact part/datasheet and antenna connectivity; read both keepouts and relevant routes/vias.
  2. Confirm M1/M2 actual drill nodes and PCB Z convention. Inspect component model heights, including bottom-side components.
  3. Run targeted STEP sections near Z=40…48 and through the +Y wall around X=10 to verify local obstructions and existing opening profiles.
  4. Obtain the selected USB-C mechanical drawing/footprint; transform its mouth, body, shell anchors and pad extents into the fixed existing board frame. Check plug/overmold insertion clearance and RF separation.
  5. Determine the real maximal available envelope with stated assembly tolerances; calculate exact component origin and wall opening from the chosen part, not from generic USB dimensions.
  6. Save a completed verification report before any enclosure cut or board mutation.
The interrupted 2D query used designators M1,M2,U5,R11,SW2,RST,DIO,CLK,3.3V,GND,C15,B1. Pagination reported one component still unread (U5), 45 route items, 18 vias and 2 keepouts on later pages. Its cursor was lp1.eyJmaW5nZXJwcmludCI6ImJvYXJkLXBkbTl1ZSIsInNlY3Rpb24iOiJjb21wb25lbnRzIiwiaW5kZXgiOjExfQ; rerun fresh if project changes make it stale.
User clarification is not yet shown to be essential for the XY alignment. The intended +Y wall, installed PCB seating/fasteners and real-world cable constraints may need confirmation after the missing inspections. Exact placement is blocked primarily by incomplete tool inspection and the unselected connector, not by a demonstrated mismatch between enclosure and board.
  • Scope and status

  • Original asset

  • Coordinate systems and board measurements

  • Mounting alignment evidence

  • STEP dimensions

  • Existing side-wall penetrations relevant to orientation

  • Board-to-cavity nominal margins

  • Provisional USB-C study location — not a placement approval

  • Nearby geometry already read