Received notification from "Copper Cleanup and Power Pads" that it finished — picking the work back up.
Received notification from "U7 U8 Copper Cleanup" that it finished — picking the work back up.
Thought for 14 sec
flux
81 days ago
Work completed so far:
Confirmed only H1–H4 are mechanical through holes; other drilled objects are routing vias.
Upgraded D2 to automotive STPS5H100BY-TR, rated 100 V/5 A.
Replaced J4 with Molex 53261-0871; pins 1–3 carry CHG_5V and pins 4–6 carry GND, supporting the 3 A output. This requires an 8-position mating harness.
ERC and component placement were clean after replacement.
Parallel executors completed the D2/J4 and U7/U8 copper-cleanup passes.
I cannot inspect or reconcile those final cleanup changes because no ACUs remain. Outstanding verification/work:
Fresh overlap, floating-copper, and dangling-trace DRC.
Live airwire inventory and complete routing.
Restore and validate CAN1/CAN2 control signals and local power connections.
Route remaining power/GND islands.
Final ERC, DRC, USB/CAN SI, power-integrity, and mechanical validation.
Platform origin remains at board center; mechanical coordinates can be translated to a lower-left datum by adding (24.00 mm, 16.00 mm).
Copper-to-edge inset/keepout: 0.30 mm (minimum requirement 0.25 mm).
No component placement or routing was performed during this setup.
Four-layer stackup
JLC3313-derived controlled-impedance starting stack, adjusted to 1.60 mm nominal thickness:
F.Cu: 35 um / 1 oz signal layer; components, primary signals and power stages.
In1.Cu: 15 um dedicated uninterrupted GND reference plane.
In2.Cu: 15 um power-plane/island layer reserved for VBAT_PROT, +5V, +3V3, CHG_5V and KP_PWR. Do not allow islands to interrupt In1 return continuity.
B.Cu: 35 um / 1 oz secondary signals and optional components.
L1-L2 and L3-L4 prepreg are 0.099 mm, Dk 4.05. The central core is 1.375 mm, Dk 4.6. The final fabricator must recalculate trace width/spacing using its field solver and impedance coupon; laminate Dk, resin content, copper plating and solder mask affect actual impedance.
Controlled-impedance pairs
Table
Pair
Target
Tolerance
Bus group
Intra-pair target
Routing intent
USB_DP / USB_DM
90 ohm differential
±10%
USB_FS
≤0.5 mm (3 ps metadata)
F.Cu over uninterrupted In1 GND; preferably no vias
VEH_CAN_H / VEH_CAN_L
120 ohm differential
±10%
VEH_CAN
≤2 mm (12 ps metadata)
F.Cu over In1 GND
VEH_CAN_H_XCVR / VEH_CAN_L_XCVR
120 ohm differential
±10%
VEH_CAN
≤2 mm
Transceiver-side segment after CMC
KP_CAN_H / KP_CAN_L
120 ohm differential
±10%
KP_CAN
≤2 mm (12 ps metadata)
F.Cu over In1 GND
The 120 ohm CAN value is a routing impedance, not a fitted termination. No termination resistor is implied.
Starting width for controlled pairs is 0.15 mm. Pair spacing is intentionally left to the impedance solver; do not release using guessed geometry. Keep all pairs at least 1.0 mm from the BUCK_SW switching-node routing and do not cross power-plane splits without an uninterrupted In1 GND reference.
Default manufacturing rules
Preferred default signal width: 0.20 mm; minimum 0.15 mm.
Default copper clearance: 0.20 mm; minimum 0.15 mm.
Standard via: 0.60 mm pad / 0.30 mm finished drill, through-hole L1-L4 only.
No blind, buried or microvias are configured.
Power via: 0.90 mm pad / 0.40 mm drill (0.25 mm annular ring), through-hole and direct connected. Use multiple vias for 1-3 A and arrays for >3 A or exposed thermal pads.
Solder-mask expansion: 0.05 mm.
Minimum silkscreen stroke: 0.15 mm.
Minimum silkscreen text height: 1.00 mm.
Normal through-hole pads: four-spoke thermal relief, 0.30 mm spokes.
U4, U5 and U10 SMD power pads: direct copper connection.
Power-routing classes
+3V3: 0.30 mm minimum for low-current branches; use wider distribution where convenient.
+5V and CHG_5V: 1.50 mm minimum for short routes; power pours are preferred for the 3.3-3.5 A design load.
VBAT_PROT and KP_PWR: 2.00 mm preferred, 1.50 mm absolute class minimum; use pours/wide copper.
Power vias are 0.40 mm drill and must be paralleled according to current and temperature-rise analysis.
These widths are starting constraints only and do not prove thermal compliance. Validate copper temperature rise, voltage drop, connector limits, via sharing and power-device thermal performance on the final routed board.
U4 RZT0020A footprint correction
Authoritative sources: TI LM656x5-Q1 datasheet SNVSCH2A (https://www.ti.com/lit/ds/snvsch2a/snvsch2a.pdf) and TI RZT0020A package drawing / example board layout, drawing 4228518 (https://www.ti.com/lit/pdf/mpqf684b).
Package: RZT0020A WQFN-FCRLF, nominal body 2.60 × 3.60 mm, 0.70 mm max height, 0.50 mm terminal pitch, pin 1 at the local -X/+Y corner.
Implementation: project-local ruleset override on the existing U4 element. The defective imported Mounts container is disabled in full, removing all duplicate unbound corner/DAP/paste-like copper. The original 21 terminal-bound pads remain and are explicitly rebuilt in place, preserving schematic terminal names, pin numbers, nets, U4 location (13.00, 0.50) mm, and the vendor RZT0020A.stp model at origin/rotation 0/scale 1/Z-up.
Perimeter lands: sixteen standard NSMD lands are 0.25 × 0.60 mm at 0.50 mm pitch. Pins 1, 7, 11, and 17 use the TI asymmetric wettable-flank corner outline with 0.575 × 0.625 mm envelope, centered at (±1.2125, ±1.6875) mm with quadrant-specific mirroring.
Exposed pad 21: one GND-bound asymmetric land with 0.95 × 2.10 mm envelope, centered at (-0.075, 0) mm; direct plane connection. The copper remains a single DAP terminal. All U4 lands use 0.05 mm solder-mask expansion.
TI specifies 85% printed solder coverage for pad 21 with a 0.125 mm stencil. Separate arbitrary paste-window apertures are not supported by the project-local component-pad override, so pad 21 uses a single -0.05 mm paste contraction (approximately 85% bounding-area coverage) rather than adding unbound copper/paste nodes.
Geometry for H1-H4: 4.00 mm circular copper, 2.20 mm plated finished drill, STD through-hole, forced annular copper on all four layers, GND net, direct connection, 0.05 mm mask expansion, and 0.50 mm component keepout beyond the copper pad.
Exact centered-board positions and element UIDs:
H1 0e0838f2-90fd-4730-ab88-cfab3c42bf81: (-21.50, -13.50) mm
H2 87889adf-2cc8-4e2f-aadc-b0037c2c76c9: (+21.50, -13.50) mm
H3 824faade-db7e-47ee-81a1-49102ab8531b: (-21.50, +13.50) mm
H4 fb29e729-84a1-4050-bc93-9a2b198a6016: (+21.50, +13.50) mm
Hole pad UIDs are each the element UID plus terminal pad suffix __56331a49-5661-48b8-b0f5-82cf0d6d1854.
Placement clearances required targeted moves: R1 to (-17.0, -14.3), F1 to (-18.5, 8.8), D1 to (-14.0, 5.4), J2 to (20.275, -7.0), J4 to approximately (18.13, 7.5), U10 to (10.7, 7.8), and C23 to (10.7, 10.5) mm.
Setup verification
Board outline: verified 48 × 32 mm.
Stackup: verified four copper layers and 1.60 mm total thickness.
In1: verified Ground Plane type.
In2: verified Power Plane type.
Via configuration: verified through-hole only.
USB and CAN pair metadata: verified each partner resolves correctly with explicit impedance/tolerance/bus properties.
Stackup validation, missing-footprint, invalid-layer, deprecated-rule and impedance/pair setup checks returned no setup findings.
Expected pre-placement findings / blockers
Existing component coordinates were generated on the former 160 × 100 mm board. After resizing, 35 components are reported outside the new outline. This is expected because placement was explicitly excluded from this task and must be resolved during the future placement phase.
All components currently have footprints; no missing-footprint blocker was reported.
The manufacturing MPN review reports 49 generic passives without exact MPNs. This is a BOM/sourcing blocker, not a board-stackup or footprint blocker, and should be resolved before manufacturing export.
The 48 × 32 mm board has 57.7% raw component-area fill; routing-aware density is tight. Placement must use both careful functional clustering and potentially bottom-side passives while preserving the no-placement decision made here.