I’m blocked again because your account has no available ACUs, so the cleanup autoroute paused before finishing.
Accomplished this session:
Applied the intended Standard 4 Layer stackup correctly.
Completed one autoroute pass earlier: 462 route nodes were added.
Fixed the stackup mismatch that caused 45 invalid-layer DRC errors.
Rechecked the board: routing congestion is now reported as acceptable.
Remaining work:
Cleanup autoroute is paused due to missing ACUs.
Final DRC still had 6 airwires before the cleanup pass:
GND/thermal-pad related connection
LED_LOG
BT_UART_CTS_IC
DIS_BT_N
BT_UART_RTS_IC
The paused cleanup run also reported a placement/preflight anomaly and a decoupling-rule routing warning that should be reviewed after ACUs are available.
Suggested next steps:
Add ACUs, then resume the paused cleanup autoroute.
Re-run final airwire/DRC checks.
Manually inspect the RF path, QFN fanout, ground/thermal pad, and crystal routing before manufacturing.