Schematic Design Review


what kind of socket does that esp-01 fit in?
The ESP-01/ESP-01S fits a 2×4 female socket header with:
  • 2.54 mm pin pitch
  • 2.54 mm row spacing—the two rows are adjacent
  • 8 contacts total
  • Through-hole, straight/vertical mounting
Use two 1×4, 2.54 mm female socket strips side-by-side or a purpose-made 2×4 ESP-01 socket. A standard wide 2×4 DIP socket/header with 7.62 mm row spacing will not fit.
can you find a part number?
I’ll find a purchasable 2×4 female socket with 2.54 mm pitch in both directions and verify its dimensions against the ESP-01 header pattern.
Use Samtec SSQ-104-01-G-D.
It is a:
  • 2×4 female PCB socket
  • Eight contacts
  • 2.54 mm contact pitch
  • 2.54 mm row spacing
  • Straight, through-hole mounting
  • Gold-plated contacts
It matches the ESP-01/ESP-01S pin pattern. A lower-cost tin-plated alternative is Samtec SLW-104-01-T-D.

Waiting for input


ESP-01 Decoupling Results
Scope status
  • Completed — components and property configuration: Added generic capacitors C6 and C7. Package options were validated against the existing generic capacitor's property configuration; generated footprints were read back after placement.
  • Completed — electrical schematic integration: Both P1 pins join existing 3.3vdc; both P2 pins join existing GND. Read-only schematic inspection confirms the nets also include ESP-01 VCC (pin 8) and GND (pin 1), respectively. Existing connections and no-connect assignments were preserved.
  • Failed/blocked — schematic adjacency: No schematic arrangement or visual-wire editing tool was exposed to this scoped agent. Symbols remain at auto-generated schematic coordinates C6 (123.7, -1956.8), C7 (123.7, -2096.8), while ESP-01 is at (179.2, 608.5). They have named power/ground stubs but are not visually adjacent to the module. A subsequent agent/editor action must move and arrange these two symbols beside the ESP-01 supply area. No arbitrary property or PCB mutation was used as a substitute.
  • Completed — PCB placement and routing: Added footprints on the bottom side adjacent to the supply header, preserving every pre-existing component placement. Supply branches use 0.4 mm traces; both ground pads already share existing GND copper with ESP-01 GND, as verified by the routing tool.
  • Completed — stale copper inspection: None detected, so no copper deletion was necessary.
  • Completed — ERC/DRC inspection: Results below. The overall request remains incomplete because schematic adjacency is blocked.
Exact capacitor configuration and placement
Coordinates below are PCB millimeters relative to board center; rotations are placement-tool absolute CCW angles.

Table


DesignatorCapacitanceGeneric packageVoltage ratingDielectric requirementRolePCB sideXYRotation
C6100 nFSMD_0603_1608Metric16 VX7R ceramicDecouplingBottom3.7016.80180°
C710 uFSMD_0805_2012Metric10 VX5R ceramicBulkBottom3.0013.60180°
Both carry Functional Group ESP-01 Power Support; Role Details identify ESP-01 VCC pin 8/GND pin 1 and explicitly specify X7R/X5R. Capacitor Type is Ceramic. No manufacturer part numbers were selected; dielectric requirements reside in Role Details, not a fabricated dielectric property.
ESP-01 VCC pad center is approximately (5.841, 15.620) mm and GND is (13.461, 13.080) mm. Capacitor centers are approximately 2.45 mm (C6) and 3.49 mm (C7) from VCC. Their bottom-side bounding boxes are clear of existing components and lie inside the board. The header-end placement avoids moving toward the opposite antenna end. No project keepout violations were detected; a manufacturer-specific antenna-clearance audit was unattempted, so this is not a claim that all pre-existing antenna copper is compliant.
The router reused local 3.3vdc copper near (4.770, 14.960) mm, adding branches of approximately 2.606 mm to C6 and 3.490 mm to C7. The GND routing request returned already-connected, one copper island shared by ESP-01 GND, C6 P2, and C7 P2.
Verification evidence
  • Pre-routing board check: valid, 22 components, 32 nets, no routing-feasibility issues.
  • Final routing-state read: 0 airwires, 0 redundant traces in 0 groups.
  • Placement mutation validation: 0 overlaps, 0 keepout violations, 0 out-of-bounds components.
  • Final targeted review for airwires, floating/overlapping copper, dangling/redundant traces, body overlaps, out-of-bounds components, keepouts, and missing footprints returned no findings.
  • Final complete ERROR/WARNING review returned no electrical-rule or schematic-legibility findings; the four temporary floating capacitor pins were resolved by wiring.
  • Pre-existing warnings remain: board density and C3 decoupling loop area. Neither applies to C6/C7.
  • Manufacturing errors: 11 missing-MPN findings, versus 9 before this batch. The two additions are C6/C7, intentionally left generic as requested. This is not a manufacturing-ready BOM or an all-checks-clean claim.
No hardware power-transient testing or simulation was performed; those are outside this local passive integration batch. Editor-focus calls could not find a requester frontend session, but project mutations and read-only verification succeeded.
  • Scope status

  • Exact capacitor configuration and placement

  • Verification evidence