Chat


How can I help you?

Explain project
Write a project description
Find schematic issues

J4
U8
C6
Capacitance
Capacitance
C11
Capacitance
Capacitance
C22
Capacitance
Capacitance
C18
Capacitance
Capacitance
C20
Capacitance
Capacitance
C21
Capacitance
Capacitance
C25
Capacitance
Capacitance
C24
Capacitance
Capacitance
C28
Capacitance
Capacitance
C27
Capacitance
Capacitance
C3
Capacitance
Capacitance
C4
Capacitance
Capacitance
C2
Capacitance
Capacitance
C15
Capacitance
Capacitance
C9
Capacitance
Capacitance
C1
Capacitance
Capacitance
C13
Capacitance
Capacitance
C17
Capacitance
Capacitance
C12
Capacitance
Capacitance
C5
Capacitance
Capacitance
C7
Capacitance
Capacitance
C14
Capacitance
Capacitance
C19
Capacitance
Capacitance
C26
Capacitance
Capacitance
C10
Capacitance
Capacitance
C8
Capacitance
Capacitance
C23
Capacitance
Capacitance
C16
Capacitance
Capacitance
L4
Inductance
Inductance
L2
Inductance
Inductance
L1
Inductance
Inductance
L3
Inductance
Inductance
Hole3
SW4
MH1
Hole1
Hole2
U6
Not Recommended for New Designs
U7
Not Recommended for New Designs
R12
Resistance
500 Ω
R30
Resistance
500 Ω
R28
Resistance
500 Ω
R24
Resistance
500 Ω
R16
Resistance
500 Ω
R13
Resistance
500 Ω
R6
Resistance
500 Ω
R5
Resistance
500 Ω
R9
Resistance
500 Ω
R26
Resistance
500 Ω
R22
Resistance
500 Ω
R3
Resistance
500 Ω
R33
Resistance
500 Ω
R8
Resistance
500 Ω
R31
Resistance
500 Ω
R14
Resistance
500 Ω
R21
Resistance
500 Ω
R34
Resistance
500 Ω
R10
Resistance
500 Ω
R11
Resistance
500 Ω
R20
Resistance
500 Ω
R2
Resistance
500 Ω
R15
Resistance
500 Ω
R29
Resistance
500 Ω
R1
Resistance
500 Ω
R7
Resistance
500 Ω
R19
Resistance
500 Ω
R27
Resistance
500 Ω
R17
Resistance
500 Ω
R23
Resistance
500 Ω
R18
Resistance
500 Ω
R25
Resistance
500 Ω
R4
Resistance
500 Ω
R32
Resistance
500 Ω
LED9
LED1
LED2
J1
LED5
LED6
LED7
LED4
LED8
LED3
SW3
D3
J5
TP3
J2
TP1
D2
TP6
TP5
TP7
TP2
J3
TP4
J7
J6
U1
U4
U2
U3
D1
Not Recommended for New Designs
U5
Universal Mini Router UPS Pro v1.0 — Feasibility and Architecture Notes
Current Architecture Decision
User selected a 3S Li-ion architecture for smooth router and ONU backup with automatic power-failure switchover. The design priority is that the router/ONU must not restart when adapter power fails.
Updated Battery Architecture
  • Battery pack: 3S Li-ion / 18650 pack.
  • Nominal pack voltage: 11.1V.
  • Full charge voltage: 12.6V.
  • Cutoff voltage target: 9.0V pack-level, assuming 3.0V/cell minimum.
  • Pack connection: use welded pack pads or a rated 3S pack connector. Avoid spring holders for production/current reliability.
User Requirement Summary
  • 12V DC adapter input via 5.5mm x 2.1mm barrel jack.
  • 3S Li-ion battery pack.
  • Safe battery charging with temperature monitoring and protection.
  • Seamless automatic switchover to battery.
  • Regulated outputs: 12V at 3A continuous / 4A peak, 9V at 2A, 5V USB at 3A.
  • JLCPCB SMT assembly, compact PCB, production-ready reliability.
Power Budget Check
Worst-case simultaneous requested output power:

Table


RailVoltageCurrentPower
12V output12V3A continuous36W
9V output9V2A18W
5V USB output5V3A15W
Total load69W
Battery-side current at 3S cutoff voltage, assuming 90% conversion efficiency:
I_BAT = P_OUT / (V_BAT_MIN × efficiency) = 69W / (9.0V × 0.90) = 8.52A
12V-only load at 3A requires:
I_BAT_12V_ONLY = 36W / (9.0V × 0.90) = 4.44A
12V peak load at 4A requires:
I_BAT_12V_PEAK = 48W / (9.0V × 0.90) = 5.93A
Key 3S Design Implication
A 3S pack makes the power current practical compared with 1S, but it introduces a charger constraint: a simple buck charger cannot fully charge a 3S pack from a 12V adapter because the pack requires 12.6V at full charge plus charger headroom. Therefore the design must use one of:
  1. A buck-boost 3S charger / power-path controller that can charge a 12.6V pack from a 12V input.
  2. A higher-voltage adapter input such as 15V to 20V, allowing a simpler buck charger.
  3. A separate boost-precharger stage feeding a 3S charger, which is less preferred for compact production.
Because the user wants 12V adapter input, the preferred production architecture is a buck-boost charger / power-path controller.
No-Reboot Switchover Strategy
To avoid router/ONU reboot during adapter failure:
  • Use an always-regulated 12V system output rail from a 4-switch buck-boost regulator. It regulates 12V whether the source is 12V adapter or 3S battery.
  • Use ideal-diode / power-path control so the adapter powers the system when present and the battery takes over when the adapter fails.
  • Add low-ESR bulk hold-up capacitance on the 12V output rail to cover controller handoff, load transient, and cable inductance.
  • Keep the 12V rail continuously enabled while the main power switch is on.
  • Detect adapter present and battery mode with comparator/MCU GPIO, but do not rely on firmware timing for the actual power-path switchover.
Proposed Functional Blocks
  1. Input protection: barrel jack, fuse/eFuse, reverse-polarity protection, TVS, input-voltage sensing.
  2. 3S charger and power path: buck-boost charger, NTC thermistor, charge status, pack connector, balancing/protection.
  3. Battery protection/BMS: overcharge, over-discharge, over-current, short-circuit protection, cell sense lines.
  4. 12V no-reboot output: 4-switch buck-boost regulator, ideal-diode source selection or power-path ORing, output current protection, hold-up capacitors.
  5. 9V output: buck converter from 12V system rail.
  6. 5V USB output: buck converter from 12V system rail with USB-A connector protection.
  7. Monitoring/UI: MCU, fuel gauge, LEDs, push button, optional OLED/I2C header, test points.
  8. Mechanical/manufacturing: mounting holes, edge connectors, JLCPCB SMT assembly, thermal copper.
Design Direction
Proceed with 3S architecture using an always-regulated 12V buck-boost output and a buck-boost 3S charger/power-path design so router/ONU loads do not see a power gap during adapter failure.
  • Current Architecture Decision

  • Updated Battery Architecture

  • User Requirement Summary

  • Power Budget Check

  • Key 3S Design Implication

  • No-Reboot Switchover Strategy

  • Proposed Functional Blocks

  • Design Direction