Tuya RS485 Probe Interface
HISTORICAL RECORD — SUPERSEDED by the T1-U migration. The completion table and fabrication gate below describe the earlier CBU revision only. Its PCB files must not be ordered for the new T1-U schematic. J3 still uses exactly four holes and standard top-silkscreen3V3 G TX RX. New module placement/routing/export are explicitly deferred until schematic approval; see the current Project Specification and T1-U migration review.
Table
| Scope item | Status | Current state |
|---|---|---|
| Four-hole CBU flashing interface | Completed | J3 is an unpopulated 1×4 row of plated through-holes at 2.54 mm pitch with 1.0 mm drills and 1.8 mm pads. Pin order is 3V3, GND, TX, RX from the programmer perspective. J3 is excluded from BOM and pick-and-place. |
| UART programming isolation | Completed | R13 (10 kΩ) isolates MAX3485 RO from the CBU RX1/programmer-TX node to avoid hard output contention while flashing. |
| Illuminex logo | Removed | Removed at user request. The raster-traced logo and custom-vector J3 labels were identified as the Gerber-export compatibility trigger. |
| Documentation | Completed | Board Bring-Up Plan includes the J3 pinout, 3.3 V-only requirement, power/backfeed warning, and reset/power-cycle workflow. |
| PCB routing | Completed | Both J3 UART branches were surgically routed. Live routing state reports 0 airwires and 0 redundant traces. |
| Validation | Passed with one justified warning | Routing feasibility check reports the board valid. ERC/DRC has no blocking errors. The intentional CBU undocumented center-EP suppression remains as the sole warning. |
| Manufacturing exports | Completed | Updated BOM, pick-and-place, IPC-D-356, and Gerber/Excellon package generated. J3 now uses standard top-silkscreen text 3V3 G TX RX, which exports correctly. |
3V3GNDTX → CBU RX1RX ← CBU TX1Completion status
Flashing interface
Final fabrication gate