Tuya RS485 Probe Interface


I’ll finish the handoff by producing fully corrected BOM and pick-and-place files with the T1-U merged into them, instead of requiring the assembler to combine a separate addendum manually. I’ll also do one final visual orientation check against the live PCB.
Production handoff is complete.
  • Corrected BOM includes the U2 exactly once.
  • Corrected pick-and-place includes its verified position: X −27.0 mm, Y 4.93 mm, 0°, top.
  • Visual orientation check passed: sensor/RS-485 holes and AC-input holes remain at opposite board ends.
  • Routing remains complete with 0 airwires and 0 redundant traces.
Use these corrected files instead of the original exported BOM and placement file:
These should be submitted with the latest Gerber ZIP.

Manufacturing and Completion Notes
HISTORICAL RECORD — SUPERSEDED by the T1-U migration. The completion table and fabrication gate below describe the earlier CBU revision only. Its PCB files must not be ordered for the new T1-U schematic. J3 still uses exactly four holes and standard top-silkscreen 3V3 G TX RX. New module placement/routing/export are explicitly deferred until schematic approval; see the current Project Specification and T1-U migration review.
Completion status

Table


Scope itemStatusCurrent state
Four-hole CBU flashing interfaceCompletedJ3 is an unpopulated 1×4 row of plated through-holes at 2.54 mm pitch with 1.0 mm drills and 1.8 mm pads. Pin order is 3V3, GND, TX, RX from the programmer perspective. J3 is excluded from BOM and pick-and-place.
UART programming isolationCompletedR13 (10 kΩ) isolates MAX3485 RO from the CBU RX1/programmer-TX node to avoid hard output contention while flashing.
Illuminex logoRemovedRemoved at user request. The raster-traced logo and custom-vector J3 labels were identified as the Gerber-export compatibility trigger.
DocumentationCompletedBoard Bring-Up Plan includes the J3 pinout, 3.3 V-only requirement, power/backfeed warning, and reset/power-cycle workflow.
PCB routingCompletedBoth J3 UART branches were surgically routed. Live routing state reports 0 airwires and 0 redundant traces.
ValidationPassed with one justified warningRouting feasibility check reports the board valid. ERC/DRC has no blocking errors. The intentional CBU undocumented center-EP suppression remains as the sole warning.
Manufacturing exportsCompletedUpdated BOM, pick-and-place, IPC-D-356, and Gerber/Excellon package generated. J3 now uses standard top-silkscreen text 3V3 G TX RX, which exports correctly.
Flashing interface
  • J3 pin 1: 3V3
  • J3 pin 2: GND
  • J3 pin 3: programmer TX → CBU RX1
  • J3 pin 4: programmer RX ← CBU TX1
  • Use 3.3 V UART logic only.
  • Prefer powering the board normally and connecting GND/TX/RX only. If powering from J3, keep 12 VAC disconnected to avoid unverified regulator backfeed.
  • Start the selected Tuya/BK7231N flashing utility, then reset or power-cycle the board. J3 does not include a dedicated reset/boot contact.
Final fabrication gate
Before ordering, visually inspect the latest Gerber/Excellon package:
  1. 84 × 20 mm closed board outline.
  2. J1/J2 cable-solder drill sizes and labels.
  3. J3 four-hole order and drill sizes.
  4. CBU perimeter pads and antenna keepout; confirm the undocumented center EP is absent.
  5. J3 standard-text label readability and clipping.
  6. Polarity of BR1, electrolytic capacitors, TVS parts, and LED.
  7. BOM quantities and pick-and-place rotations.
  • Completion status

  • Flashing interface

  • Final fabrication gate