Airwire Fix


Created a project doc

Current ERC DRC and Airwire Report

View Document

Current ERC DRC and Airwire Report
Review timestamp: 2026-08-09T10:11:33.978Z
Totals
  • Airwires: 43 errors
  • Floating copper: 2 errors
  • Overlapping copper: 8 errors
  • Dangling traces: 0
  • ERC: 1 error
  • Total listed PCB DRC errors: 53
Airwire list
  1. 33808389
  2. Trace 4706
  3. Trace 1c93
  4. Trace 2145
  5. Trace 7fa6
  6. Trace 814f
Fresh review completed:
  • Airwires: 43
  • PCB DRC: 53 errors — 43 airwires, 8 overlaps, 2 floating-copper
  • Dangling traces: 0
  • ERC: 1 — U10:VIO_SEL
The complete itemized list is in Current ERC DRC and Airwire Report.
Fix all the overlpas flaoting coppers and airwires
I’ll resolve the fixed-geometry overlaps and floating copper first, then clean stale traces, route the remaining connections, and finish with a full ERC/DRC verification.
Copper geometry is clean. Routing preflight found 293 duplicate-via records from the imported layout; I’m removing those duplicates before routing so the router does not build on corrupted transitions.
Overlap and copper cleanup completed:
  • Overlapping copper: 0
  • Floating copper: 0
  • Dangling traces: 0
  • Airwires: 54
Routing is blocked by 293 duplicate-via records in the imported layout. The preflight exposes their coordinates but not enough UID/net data to safely remove only the duplicates, so I did not risk deleting valid vias. A dedicated duplicate-via cleanup capability or manual editor cleanup is required before safely routing the 54 airwires.
Back up and diagnose
Create cleanup checklist
Research cleanup method
Route connections individually
Export safety backup

Active Routing Clearance Rule Audit
Executive finding
The effective 0.5 mm clearance is enforced by Flux system-default, node-type-specific minKeepOut rules on route segments, vias, pads, and polygons. The project rule Auto-Layout: Universal Keepout sets a requested clearance of 3.8 mil (~0.0965 mm) and a minimum of 3.5 mil (~0.0889 mm), but those values cannot reduce a separate, more restrictive 0.5 mm minimum inherited by each copper node type.
Flux evaluates clearance as a pairwise geometric constraint. Where multiple minimum constraints apply, the most restrictive applicable minimum wins. Therefore:
effective clearance = max(requested keepOut, applicable minKeepOut constraints on both objects)
For ordinary trace-to-trace, trace-to-pad, trace-to-via, via-to-pad, or copper-to-polygon routing, at least one active system rule contributes 0.5 mm, so the 3.8 mil request is clamped upward to 0.5 mm.
Priority terminology
The rule inspection API does not expose a numeric cascade priority. Priority below is reported by effective precedence class:
  1. Project !important override — highest declaration precedence, if it targets the same node/property.
  2. Project rule — user/project-authored rule.
  3. System-default specialized rule — applies conditionally (impedance, current, net type).
  4. System-default node-type rule — baseline for trace, pad, via, polygon, etc.
Important caveat: distinct constraints are not necessarily replacements. A 3.5 mil project minKeepOut does not automatically cancel a different 0.5 mm node minimum; the geometric engine may retain the stricter bound.

Table


Rule namePriorityScopeClearance / spacing valueSourceEffect
Auto-Layout: Universal KeepoutProject !important for minKeepOut; project rule for keepOuttrace, pad, via, fill, netkeepOut = 3.8 mil (0.0965 mm); minKeepOut = 3.5 mil !important (0.0889 mm)Project / Auto-Layout ruleRequests ~0.1 mm universal spacing, but does not remove stricter 0.5 mm node-type minima.
Component system defaultSystem node-type defaultelementkeepOut = element(0.5 mm)Flux system defaultEnforces 0.5 mm component-to-component spacing. It is not the direct cause of copper escape failure because it targets element, not trace/pad/via copper.
Trace system defaultSystem node-type defaultrouteSegmentminKeepOut = net(0.5 mm) polygon(0.5 mm)Flux system defaultDirectly enforces at least 0.5 mm from other nets and polygons for every trace segment. Major cause.
Via system defaultSystem node-type defaultviaminKeepOut = net(0.5 mm) polygon(0.5 mm)Flux system defaultDirectly enforces at least 0.5 mm from other nets and polygons for every conventional via. Major cause.
Pad system defaultSystem node-type defaultpadminKeepOut = net(0.5 mm) polygon(0.5 mm)Flux system defaultDirectly enforces at least 0.5 mm around pads relative to other nets/polygons. Major cause at NAVC1 pin escape.
Polygon system defaultSystem node-type defaultpolygonminKeepOut = net(0.5 mm) polygon(0.5 mm)Flux system defaultForces traces/vias/pads to remain 0.5 mm from unrelated copper polygons and other polygons. Relevant if pours/polygons are present locally.
Net system defaultSystem node-type defaultnetminKeepOut = polygon(0.5 mm)Flux system defaultAdds a 0.5 mm minimum specifically between net copper and polygons.
Smart Via system defaultSystem node-type defaultsmartViakeepOut = 250 µm (0.25 mm)Flux system default / autorouter via primitiveRequests 0.25 mm around Smart Vias, but conventional via/pad/net minima can still raise pairwise clearance to 0.5 mm.
Nets with Impedance PairSystem specialized rulenet[impedancePair]Dynamic keepOut = calculateImpedanceTraceKeepout() and dynamic pair keepInFlux system default / controlled-impedance constraintApplies only to configured differential pairs. It may exceed 0.5 mm for those pairs, but does not explain the general NAVC debug-net result.
Nets with CurrentSystem specialized rulenet[current]No clearance; dynamic trace width onlyFlux system default / current constraintNot a clearance source. Included because it affects routability through width, not spacing.
Nets with ImpedanceSystem specialized rulenet[impedance]No explicit clearance; dynamic trace widthFlux system default / impedance constraintNot the source of the general 0.5 mm clearance.
Blocked NAVC nets 0.15 mm routingProject rule, !importantRoute segments beneath BAR_NRST_NAVC, NRST_NAVC, SWDIO_NAVC net UIDstraceWidth = 0.15 mm !important; no clearance overrideProject-local ruleNarrows traces but leaves all 0.5 mm minKeepOut constraints active; therefore it cannot solve clearance-limited escape routing.
NAVC USB escape feasibility widthProject !importantUSB_DP_NAVC and USB_DM_NAVC netsTrace width 0.15 mm, min trace width 0.10 mm; no clearance overrideProject-local feasibility ruleAffects width only, not the 0.5 mm spacing floor.
GND narrow pin escape for fine padsProject !importantGND netTrace width 0.15 mm; no clearance overrideProject-local ruleAffects width only. GND still participates in the 0.5 mm trace/pad/via minimum clearance to unrelated nets.
PWM exact signal trace widthProject !importantPWM_0–PWM_7Trace width 0.15 mm; no clearance overrideProject-local ruleWidth only; unrelated to NAVC spacing floor.
Rules that are active but not clearance constraints
The following active rules influence routing order or geometry but do not impose a fixed copper clearance:
  • Net auto-layout priorities: High Speed = 1, Analog = 2, Power = 3, Medium Speed = 4, Low Speed = 5, Ground/default = 6.
  • Standard four-layer stackup and through-via geometry: 0.6 mm via pad, 0.3 mm drill.
  • Trace default width: 10 mil (~0.254 mm).
  • Trace minimum Y size: 0.15 mm.
  • Board inset margin: 0.4 mm, which affects board-edge routing only.
  • Protected polygons: dynamic shouldProtectPolygon(0.1); no evidence of a protected polygon or footprint keepout specifically enclosing NAVC1 was reported.
Imported/autorouter constraint evidence
Preflight reports approximately 372 duplicate-via warnings. These are imported/generated routing artifacts rather than clearance rules. The router removes duplicates in its internal model, but the large number demonstrates a very dense via topology. With 0.6 mm via pads plus 0.5 mm pairwise clearance, these vias create large blocked regions even though they are not themselves the source of the 0.5 mm rule.
No preflight anomalies reported:
  • ROUTING_PIN_INSIDE_KEEPOUT
  • ROUTING_UNROUTABLE_PIN
  • ROUTING_PIN_OUTSIDE_BOUNDARY
  • NAVC1-specific protected area or footprint keepout
Therefore the failure is a general clearance/copper-density issue, not a hidden NAVC1 footprint keepout.
Can the 0.5 mm constraint be overridden?
Yes, at the project-rule level, but not by changing trace width alone. A valid override must address minKeepOut, not only keepOut or traceWidth.
Requirements for an effective override
  1. Create a more specific project rule with minKeepOut and keepOut set to the desired manufacturing clearance using !important.
  2. Target every copper object participating in the pairwise check. Overriding only the new NAVC trace may be insufficient because the neighboring pad/via/trace can still contribute its own 0.5 mm minimum.
  3. The practical choices are:
    • A global project override for routeSegment, via, pad, net, polygon, or
    • Exact UID/selector overrides for the NAVC target traces plus every local blocking pad, trace, via and polygon.
  4. Re-run preflight and DRC to confirm the effective clearance and ensure the new value is supported by the PCB manufacturer.
A typical manufacturable project override would be 0.15–0.20 mm, depending on the selected fabricator and copper weight. The existing 3.8 mil (~0.097 mm) value is aggressive and below many standard-cost manufacturing limits; it should not be treated as manufacturing-ready without vendor confirmation.
Important limitation
System-default rules are not edited directly. They are superseded with a project-local, more specific !important rule. Because clearance is pairwise and the stricter side wins, a narrow net-only override may appear to apply yet still leave an effective 0.5 mm obstacle boundary from adjacent copper.
Final conclusion
The 0.5 mm constraint comes from active Flux system-default minKeepOut rules on traces, vias, pads and polygons. The 3.8 mil Auto-Layout rule is a requested keepout, not a guaranteed effective clearance reduction. It can be overridden, but only by explicitly superseding the 0.5 mm minKeepOut constraints for all relevant copper participants and validating the chosen clearance against manufacturing capability.
  • Executive finding

  • Priority terminology

  • Active clearance-related rules

  • Rules that are active but not clearance constraints

  • Imported/autorouter constraint evidence

  • Can the 0.5 mm constraint be overridden?

  • Requirements for an effective override

  • Recommended safe value

  • Important limitation

  • Final conclusion