Project Start Prompt


Received notification from "Mid-Layer 4 Router Fix" that it finished — picking the work back up.

flux

The workaround executor has settled. I’m reconciling its exact retained/reverted result against a fresh live DRC and targeted-routing canary now; I’ll continue only from the verified state.

flux

I exhausted the safe project-side workarounds. This is conclusively a Flux targeted-router backend defect, not a malformed project layer reference:
  • Active stackup canonically defines Mid-Layer 4.
  • Existing copper correctly serializes as routeSegment.layer="Mid-Layer 4".
  • The targeted router rejects that valid value before pathfinding.
  • Normalizing the stackup broke via connectivity.
  • Migrating copper to Mid-Layer 2 created shorts, airwires, and floating copper.
  • All experiments were atomically reverted: checkpoint #81f819bf, revert #ba5278cf.
  • Fresh state: 63 airwires, 2 protected USB-C warnings, 0 other DRC findings.
I filed an updated engineering escalation containing the serialized field, node counts, commits, reproduction steps, and failed workarounds.
Practical paths forward
  1. Use explicit copper primitives for each remaining connection; this bypasses the targeted router but is effectively manual routing.
  2. Export the design to KiCad or another EDA tool and complete placement/routing there.
  3. Wait for Flux to correct the backend layer importer, then resume targeted routing here.
Given the repeated failures and the unresolved VCAP/SDRAM placement redesign, exporting to KiCad is currently the lowest-risk path to completing this board. Flux support can be reached at https://docs.flux.ai/Introduction/getting-support.
Export to KiCad
Manual routing plan
Prepare handoff package
Audit export readiness

Waiting for input


Schematic is Auto-placed

The schematic has been arranged automatically. Flux can redraw it to be more readable, with components placed in related groups and wires drawn more legibly. This takes about 10-60 mins.

VCAP1 Package and Via-in-Pad Feasibility Audit
Scope and executive verdict
This was a read-only audit. No schematic, component, placement, stackup, rule, trace, via, or copper object was changed.
Overall verdict: no 0402 or 0201 option provides a certifiable, STM32H743-compliant, no-existing-copper-reroute VCAP1 implementation. All four requested options are FAIL. The layout throat is physically blocked at production clearances, and the reviewed nominal-2.2 uF MLCCs do not provide a guaranteed effective capacitance inside ST's 1.76–2.64 uF accepted range after initial tolerance and DC-bias derating.

Table


OptionVerdictPrimary blockers
0402 conventional pads + nearby via(s)FAILTop throat split by FMC_D1; minimum 0402 land span does not fit either side. Bottom transition intersects FMC_D11. Candidate effective capacitance is not guaranteed compliant.
0402 via-in-padFAILSame land/throat conflict; current 0.6/0.3 mm via cannot fit a 0402 land. A VIPPO via would require a new via definition/process and still conflicts with existing copper. Electrical margin is not guaranteed.
0201 conventional pads + nearby via(s)FAILEven Murata's minimum 0201 land span is 0.0186 mm wider than the largest legal Top sub-corridor at the board's minimum clearance; vertical orientation enters adjacent U1 pads. No legal standard-via site. Strong DC-bias derating.
0201 via-in-padFAILRequires HDI laser microvia/VIPPO absent from the stackup/rules, and the capacitor land still does not fit the fixed copper throat. Strong DC-bias derating and severe assembly/rework burden.
No exact capacitor center, rotation, pad centers, VCAP/GND via centers, or trace geometry is issued because none is certifiable under the fixed-copper constraints.
Verified board baseline
  • U1 VCAP1 is pin 81 on net MCU_VCAP1, centered at (5.5500, 29.2500) mm.
  • U1 VCAP1 copper is 1.800 x 0.280 mm, spanning approximately x=4.6500…6.4500 mm, y=29.1100…29.3900 mm.
  • Adjacent U1 pads are PB11 at y=28.7500 mm and 3V3/VDD at y=29.7500 mm. Their bare copper gap to VCAP is 0.2200 mm.
  • U2 DQ2 copper occupies approximately x=8.1225…9.4175 mm, y=28.9000…29.5000 mm. The raw VCAP-to-DQ2 x-gap is 1.6725 mm.
  • Board universal copper keepout is 3.8 mil = 0.0965 mm, with an absolute minimum of 3.5 mil = 0.0889 mm.
  • Existing signal traces in this area are 0.254 mm wide.
  • Standard through vias are 0.600 mm pad / 0.300 mm drill, L1–L6.
  • Stackup is six copper layers: Top signal, L2 ground, L3 signal, L4 power, L5 ground, Bottom signal.
  • Live DRC baseline at audit time: 63 airwires, zero returned non-connectivity DRC errors in the reviewed overlap/layer/stackup/via categories, and two dangling-trace warnings corresponding to the intentional USB-C stubs.
C15 remains a remote 0603 at (-18.0000, 7.5000) mm and the VCAP1 connection remains one of the airwires.
Authoritative STM32H743 requirement
ST specifies one 2.2 uF external capacitor at each VCAP pin when the internal regulator is used, with ESR <100 mOhm and ±20% capacitance variation tolerated. Therefore the acceptable realized capacitance interval is 1.76 to 2.64 uF, not merely a nominal 2.2 uF marking. ST also instructs that filtering capacitors be placed as close as possible to, or below, their associated power pins. VCAP is the VCORE node and can operate up to approximately 1.35–1.40 V depending on voltage scaling.
Sources:
MLCC candidates and effective-capacitance review
0402 candidate: Murata GRM155R61C225KE11D
  • Package: 0402 / 1005 metric.
  • Nominal: 2.2 uF, 16 V, X5R, ±10%.
  • Body: approximately 1.0 x 0.5 mm.
  • Production availability is supported by distributor listings; equivalent TDK C1005X5R1C225K050BC is listed by TDK as Production.
  • A same-construction Murata typical-characteristic sheet shows roughly -10% capacitance at 1 V and -20% at 2 V. Linear reading at 1.35 V is approximately -13.5%, giving about 1.90 uF typical before initial tolerance. Applying the ±10% initial tolerance gives about 1.71 uF, below ST's 1.76 uF floor. Temperature and aging margin make the guarantee weaker, not stronger.
  • Typical ESR minimum is approximately 7–10 mOhm around a few MHz, comfortably below 100 mOhm as a typical value, but no reviewed approval sheet supplied a guaranteed <100 mOhm production limit at the relevant operating point.
Electrical verdict: not recommendable as a guaranteed 2.2 uF VCAP part. Typical behavior may work, but the available data does not guarantee the required effective capacitance after tolerance and bias.
Sources:
0201 candidate: Murata GRM033R60J225ME47D/E
  • Package: 0201 / 0603 metric.
  • Nominal: 2.2 uF, 6.3 V, X5R, ±20%.
  • Body: 0.6 ±0.09 x 0.3 ±0.09 x 0.3 ±0.09 mm.
  • Murata recommended land ranges: inter-land gap 0.23–0.30 mm, land length 0.25–0.35 mm, land width 0.30–0.40 mm. The smallest recommended total copper span is therefore 0.73 mm.
  • Typical DC-bias curve is approximately -15% at 1 V and -40% at 2 V. At 1.35 V the approximate typical derating is -23.8%, giving about 1.68 uF typical before initial tolerance. Applying ±20% initial tolerance gives approximately 1.34 uF.
  • Typical characteristic resistance/ESR reaches roughly 10–20 mOhm near several MHz, but is not a guaranteed production maximum.
Electrical verdict: unequivocally unsuitable for guaranteed VCAP compliance. Even its typical effective capacitance at VCAP voltage is below ST's 1.76 uF minimum before tolerance is applied.
Sources:
Fixed-copper geometry proof
Top corridor
The existing FMC_D1 0.254 mm vertical escape occupies centerline x=7.4662 mm from y=28.8035 to 29.6763 mm. Its copper x-bounds are approximately 7.3392…7.5932 mm.
At the board's minimum 0.0889 mm clearance:
  • Legal width between U1 VCAP copper and the left edge of FMC_D1 is:
    • 7.3392 - 0.0889 - (6.4500 + 0.0889) = 0.7114 mm.
  • Legal width between the right edge of FMC_D1 and U2 DQ2 copper is:
    • (8.1225 - 0.0889) - (7.5932 + 0.0889) = 0.3515 mm.
Comparison with minimum recommended land spans:
  • 0402 TDK recommended overall span: 0.95–1.45 mm. It cannot fit either sub-corridor.
  • 0201 Murata minimum overall span: 0.73 mm. It exceeds the largest legal sub-corridor by 0.0186 mm, before courtyard, placement tolerance, solder-mask registration, or trace connection allowance.
A 90-degree orientation does not rescue either package. The minimum 0201 0.73 mm longitudinal span centered on VCAP extends approximately y=28.885…29.615 mm, entering both adjacent U1 pad regions (PB11 ends at y≈28.890; VDD begins at y≈29.610) before required clearance. A 0402 is larger.
Other fixed Top copper further removes margin:
  • 3V3: (5.5500,29.7500)→(6.8840,29.7500), then diagonal to (7.9340,30.8000).
  • FMC_D2: (5.5500,28.3300)→(6.8840,28.3300), then diagonal to (7.9340,29.3800).
  • FMC_D1 continues toward U2 DQ1 near y≈30.18.
  • No current via center exists in x=4.5…9.5, y=28.0…31.0 that can be reused as a legal VCAP or GND transition.
Bottom corridor
Bottom FMC_D11 is a 0.254 mm trace:
  • (19.1586,26.8000)→(16.5351,29.4235)
  • (16.5351,29.4235)→(5.3421,29.4235)
  • (5.3421,29.4235)→(3.3895,27.4709)
Its horizontal copper occupies y≈29.2965…29.5505 mm, directly under the VCAP1 pad/escape throat. At a hypothetical transition center (6.90,29.25), the centerline separation is only 0.1735 mm. Against a current 0.300 mm via radius and 0.127 mm trace half-width, the raw copper clearance is -0.2535 mm; relative to the 0.0889 mm minimum rule, the shortfall is 0.3424 mm.
Therefore no Bottom-side capacitor option can be reached by a current-style through via without rerouting FMC_D11.
Option-by-option assessment
1. 0402 conventional pads + nearby via(s): FAIL
  • Exact candidate geometry: none certifiable.
  • Top clearance: minimum 0.95 mm recommended land span versus only 0.7114 mm legal width on the VCAP side of FMC_D1 and 0.3515 mm on the U2 side.
  • Bottom clearance: any local through transition overlaps FMC_D11 by 0.2535 mm raw copper at the previously evaluated transition location.
  • Low-inductance intent: not met. Detouring around the fixed trace/via throat would produce a long, separated loop and is not a valid VCAP placement.
  • Manufacturing: conventional 0402 assembly is routine, but a standard 0.6/0.3 mm nearby via has no legal site in the throat.
  • Electrical: reviewed 16 V ±10% 0402 is approximately 1.71 uF at worst when typical DC bias and initial tolerance are combined; not guaranteed above 1.76 uF.
2. 0402 via-in-pad: FAIL
  • Exact candidate geometry: none certifiable.
  • Land/copper: via-in-pad does not reduce the capacitor's required land span, so the FMC_D1/U1/U2 conflict remains.
  • Current via geometry: 0.600 mm pad diameter is equal to the maximum recommended 0402 land width and larger than typical land length; it leaves no registration, annular, mask, or capping margin.
  • Manufacturable geometry if copper were changed: approximately 0.15–0.20 mm finished mechanical hole with 0.40–0.45 mm land, nonconductive resin fill, planarization, and copper cap/plating over (IPC-4761 Type VII / VIPPO). Final dimensions must be approved by the selected fabricator.
  • Risks: incomplete fill or non-planarity causes solder loss, voiding, tombstoning, and joint-height variation. Requires microsection/cross-section process control and tighter incoming inspection; rework is harder than ordinary 0402.
  • Electrical: same effective-capacitance failure as option 1.
3. 0201 conventional pads + nearby via(s): FAIL
  • Exact candidate geometry: none certifiable.
  • Top clearance: 0.73 mm minimum recommended land span versus 0.7114 mm maximum legal sub-corridor; 0.0186 mm short even at the absolute minimum clearance, without production tolerances.
  • Rotation: vertical orientation enters PB11 and VDD pad-access regions.
  • Nearby via: the current 0.600 mm via plus two minimum clearances requires 0.7778 mm, larger than the available local trace-to-trace gaps; no reusable via exists in the search window.
  • Low-inductance intent: not met because the only possible response would be a remote via/detour.
  • Manufacturing: 0201 placement requires tighter paste-volume, placement, solder-mask, AOI, and reflow control than 0402; field rework is difficult.
  • Electrical: approximately 1.68 uF typical at 1.35 V before tolerance and approximately 1.34 uF after -20% tolerance; fails ST's minimum.
4. 0201 via-in-pad: FAIL
  • Exact candidate geometry: none certifiable.
  • Land/copper: same 0.73 mm minimum span conflict as option 3.
  • Via technology required: a 0.075–0.10 mm laser microvia with approximately 0.20–0.25 mm land, normally L1→L2, filled and copper capped/planarized. A 0.1 mm through hole through the 1.48 mm board would have an impractical aspect ratio and is not a credible substitute.
  • Stackup impact: the current project defines only L1–L6 0.6/0.3 mm through vias. Adding an L1→L2 laser microvia is an HDI stackup/rule/manufacturing change, not a no-change implementation.
  • Risks/cost: sequential-lamination/HDI premium, via-fill and cap process control, solder void risk, SPI/AOI and often X-ray sampling, very low manual reworkability, and greater tombstone/placement sensitivity.
  • Electrical: strongest capacitance-derating failure of all four options.
Via-protection/manufacturing references:
Minimum design change required
A compliant implementation requires deliberately reopening the VCAP1 throat. The minimum localized physical change is:
  1. Reroute the U1-side FMC_D1 escape away from x≈7.4662 mm or relocate U2/its escape field enough to create a certified capacitor land and local GND-via keepout; and
  2. For a Bottom implementation, reroute the horizontal FMC_D11 segment away from y=29.4235 mm to permit a VCAP transition and adjacent GND via.
Because the reviewed nominal-2.2 uF 0402/0201 candidates also lack guaranteed effective-capacitance margin, the reopened area should preferably accept the existing 0603-class part or another manufacturer-approved part whose minimum effective capacitance at 1.40 V, including initial tolerance, temperature, and aging, is at least 1.76 uF, with ESR guaranteed below 100 mOhm.
If copper rerouting remains prohibited, the plain conclusion is: VCAP1 cannot be implemented compliantly in this board revision.
Completion status
  • STM32H743 VCAP requirement research: completed.
  • 0402 and 0201 candidate research with nominal/effective distinction: completed.
  • Current land patterns, U1/U2 pads, Top/Bottom copper, vias, stackup and rules inspection: completed.
  • Four-option feasibility verdicts: completed — all FAIL.
  • Project mutations: none.
  • Scope and executive verdict

  • Verified board baseline

  • Authoritative STM32H743 requirement

  • MLCC candidates and effective-capacitance review

  • 0402 candidate: Murata GRM155R61C225KE11D

  • 0201 candidate: Murata GRM033R60J225ME47D/E

  • Fixed-copper geometry proof

  • Top corridor

  • Bottom corridor

  • Option-by-option assessment

  • 1. 0402 conventional pads + nearby via(s): FAIL

  • 2. 0402 via-in-pad: FAIL

  • 3. 0201 conventional pads + nearby via(s): FAIL

  • 4. 0201 via-in-pad: FAIL

  • Minimum design change required

  • Completion status