Project Start
flux
Superseded for routing readiness by Rev C5.2b Routing Release and Reply4: the slit is withdrawn; stitching, selective thermals and U1 copper area are post-route deliverables. P1–P3 are now inactive for the traces-first pass, with exact geometry retained for re-enable. The protected-plane Info is cleared; zero excluded/ignored pins remain.
Placement delta
| ref | x_project | y_project | x_flux | y_flux | rot | side | note |
|---|---|---|---|---|---|---|---|
| C2 | 48.80 | 4.20 | 8.80 | -20.30 | 0 | bottom | +0.3 X (C5.2) |
| C3 | 48.80 | 6.90 | 8.80 | -17.60 | 0 | bottom | +0.3 X |
| C4 | 53.50 | 4.20 | 13.50 | -20.30 | 0 | bottom | +0.3 X |
| C5 | 53.50 | 6.90 | 13.50 | -17.60 | 0 | bottom | +0.3 X |
| C36 | 58.20 | 4.20 | 18.20 | -20.30 | 0 | bottom | +0.3 X (DNP) |
| C37 | 58.20 | 6.90 | 18.20 | -17.60 | 0 | bottom | +0.3 X (DNP) |
| TP24 | 44.80 | 42.60 | 4.80 | 18.10 | 0 | bottom | was (44.8, 39.4): 0.06 mm into the J4 left locator hole (44.46, 40.0) |
| FID6 | 47.60 | 43.50 | 7.60 | 19.00 | 0 | bottom | was (50.0, 39.4): 0.2 mm into the J4 locator hole (49.54, 38.73); O 3 mm copper-free ring |
| PS1 | 35.20 | 10.40 | -4.80 | -14.10 | 0 | top | no move — pins 1..6 confirmed at X 23.2/27.2/31.2/35.2/43.2/47.2 (Flux -16.8/-12.8/-8.8/-4.8/3.2/7.2), Y 18.2 (Flux -6.3) |
Table
| Scope | Status | Evidence / remaining limitation |
|---|---|---|
| Six MLCC placement deltas | Completed | C2/C3 X48.8; C4/C5 X53.5; C36/C37 X58.2. Y4.2/6.9, Bottom0° retained. No second +0.3 increment when the superseding CSV arrived. |
| TP24 and FID6 authorized moves | Completed | TP24 source(44.8,42.6), Flux(4.8,18.1); FID6 source(47.6,43.5), Flux(7.6,19). Both Bottom0°, existing copper dimensions unchanged. 2D readback verifies both. |
| PS1 geometry/pins | Completed: preserved and routing-accessible | Component remains Flux(−4.8,−6.3); CSV body-datum row was explicitly “no move.” Pads unchanged at source X23.2/27.2/31.2/35.2/43.2/47.2, Y18.2. All four formerly excluded primary pins participate in final preflight. Provisional drills still gate fabrication only. |
| MAINS class correction | Completed | Seven nets now minimum1.0/preferred1.5 mm; clearance declaration1.0 mm. Computed readback confirms min1.0 and trace1.5 on all seven. Removed obsolete3.0 and3.2 mm rules; no pad-pair waiver remains. |
| Four continuous wall zones | Completed: preserved per accepted implementation | Reply3 explicitly accepts these instead of net-selective S/M. No further unsupported selective-region experiment. No ignored-keepout warning in final preflight. Actual routed copper/creepage audit remains necessary. |
| RV1/C1 housing zones | Completed | RV1 lower Y25.7, upper47.5, X8.25–25.25; C1 unchanged X27.25–38.25/Y27.5–49. Top only; own-pad exceptions no longer requested. |
| Fiducial pour rings / J4 hole rule | Completed as declarations | Six fiducials get1 mm fill/polygon margin around Ø1 mm dots, forming Ø3 mm pour-exclusion diameter;3 mm silk margin retained. FID1’s stronger3.2 mm copper separation preserved. Added J4 locator pad-to-hole0.3 mm declaration; no holes altered. Actual filled-ring and silk clearance audit remains. |
| Board-wide GND fill and mains-side generated via removal | Completed | GND connectedLayers cleared and automatic stitching disabled. Final scene tree has only P1/P2/P3-derived fills and no via/smartVia nodes. The prior mains-side island via is gone. Automatic L/SW fill sources also cleared; no copper plane of those nets remains. |
| Explicit P1/P2/P3 outer boundaries | Completed | Three net-parented GND polygons created and read back with exact intended physical boundaries/layers, below. |
| P1 fill-only slit | Failed / not implemented | A Bottom zone at X49.7–50.3/Y30.5–37 with only fill/polygon zero-margin selectors still generated six unrelated component keepout Errors. It was removed, not left as a claimed fill-only restriction. Current P1 has no slit. No verified fill-only region interface was established. |
| Four U1 stitches, ≥8 U5 stitches, selective SELV thermal relief and ≥30 mm² actual U1 copper | Unattempted / pending ground-detail pass | No new vias placed. Existing Direct Connect defaults were not converted to selective SELV thermals. Gross pour boundary is not proof of filled copper area or connectivity. These remain explicit ground-completion requirements; latest routing sequence places pours/stitching after traces. |
| Autorouting, neckdowns, routed lengths, silk cleanup, exports | Unattempted by lead’s bounded brief | Lead owns full routing launch. No sourcing, component replacement, schematic/net changes, or manufacturing export. |
Table
| Object | Final Flux X,Y mm | Layer / rotation |
|---|---|---|
| C2 / C3 | (8.8,−20.3) / (8.8,−17.6) | Bottom0° |
| C4 / C5 | (13.5,−20.3) / (13.5,−17.6) | Bottom0° |
| C36 / C37 | (18.2,−20.3) / (18.2,−17.6) | Bottom0°, DNP preserved |
| TP24 | (4.8,18.1) | Bottom0° |
| FID6 standalone dot | (7.6,19.0) | Bottom0° |
95838896-1ea1-4576-a7b2-550477538c53: L,N,L_FUSED,L_CHOKE,N_CHOKE,VCAP_P,VCAP_N; minTraceWidth1.0 mm, traceWidth/preferredTraceWidths1.5 mm, keepOut/minKeepOut1.0 mm, important where applicable.f64563e3-7a6b-4bc1-8229-68549829cf47, mains-track separation 91fd3c3d-01a0-4a38-b9d1-1b3e9a9e1941, conflicting L/N minimum-width ruleset 40745540-1925-460c-8a7d-b01bca149a4b. Existing L/N inline1.5 mm declarations remain, but computed minimum is correctly1.0 and preferred1.5 under the new class.48ada1c7-eb31-4a51-819c-0abf2991cc96 and SW rule 69167b80-03e0-4e35-989b-85fecc413737: clear connectedLayers to eliminate automatic full-board fills, retain Top layer and SW0.5/0.8 mm widths. This is not a certification that the router enforces no-via/Top-only topology.a0fb0b92-0dc0-4657-96b5-9225d521d8ad: base0.2 mm; fill/polygon1 mm; text/line/circle/rectangle3 mm.079be8d7-147c-4935-b67c-839e6834d456: #J4 pad[padHoleType="HOLE"], minKeepOut0.2 mm with pad0.3 mm; keepOut0.25 mm with pad0.3 mm.c1424fcd-b3e9-4b52-bbbb-a42e64176edd: Flux center(−23.25,12.1), size17×21.8 mm. Housing ruleset description updated accordingly.Table
| Zone | Source bounds | Layers |
|---|---|---|
| Slot-band wall | X37–41.5/Y3.5–46 | All |
| Bottom bridge wall | X30–46.5/Y0–3.5 | All |
| Lower setback wall | X30–41.5/Y3.5–6 | All |
| Top bridge wall | X33–46.5/Y46–49 | All |
| RV1 housing | X8.25–25.25/Y25.7–47.5 | Top |
| C1 housing | X27.25–38.25/Y27.5–49 | Top |
e9fa93db-a3b3-44dc-9cd4-0a8320197bed: source vertices(46.5,0.4),(79.6,0.4),(79.6,48.6),(46.5,48.6),(46.5,46),(41.5,46),(41.5,3.5),(46.5,3.5).26c973f6-acdb-49a6-a482-de5aaab0d4ad: X43.5–56/Y23.7–35.dd87a953-1512-49b0-b6b8-0531c67b23cf: X66.65–79.65/Y15.65–29.35.ROUTING_SIGNAL_PLANE_PROTECTED, GND on layer0 will be protected. Polygon protected rules are false; this is the router’s advisory plane treatment and should be monitored during the lead’s routing pass.Result — 2026-10-05
Assigned-item disposition
Exact persistent changes
Placement
Rules
Regions retained
GND polygons