Project Start


Worked for 1 hr
Thought for 13 sec
Referenced guidance.
Thought for 21 sec
Board check: 22 issue(s) found
Thought for 25 sec
Reading PCB Placement Handoff's report…
Thought for 21 sec
Routing paused
Thought for 28 sec
Thought for 17 sec
Checking routing progress.
Thought for 24 sec
Awaiting 1 task
"PCB Placement Handoff" completed.
Thought for 1 hr 23 mins
Thought for 23 sec
Managing 1 task
Thought for 25 sec
Thought for 22 sec
Awaiting 1 task
Thought for 20 sec
Awaiting 1 task
"PCB Placement Handoff" completed.

flux

The one authorized auto-route run produced no new copper. Direct cleanup then reduced 56 → 53 airwires, preserving placement, rules, and frozen copper.
The updated routing report records remaining endpoints, individual blockers, DRC findings, and measurements. Zero-airwire completion was not achieved; P2 filled-area verification and final redundant-copper cleanup remain unfinished. The PCB is not fabrication-ready.

Four IC Pin1 and Model Alignment
Historical inspection — U1 blocker superseded, 2026-10-05: A later explicitly authorized pass deleted the nine local U1 pad overrides and rotated the complete native part to Top/270° at the unchanged center. Actual pin1 is now source (55.23,34.61); native ordering, model axis and model dot agree. U2/U3 comments-circle removal was attempted but safely rolled back after failed asset verification, so their original artwork remains. See Rev C5 U1 Restoration and Routing Gates for the current table/render and remaining routing blockers. The observations below describe the pre-restoration state.
Scope and disposition
Inspected only installed U1, U6, U2 and U3, their three source part projects, source footprint/model transforms, and filtered installed/source renders. No component, pad, model, silkscreen, board or routing geometry was changed. No whole-board checks or routing were run.
  • Completed: actual pad ordering/coordinates, source-part identification, installed lead-axis comparison, and source pin-1 marker inspection for all four.
  • Failed/blocked: U1 does not meet the required pad-1 coordinate. Its model/silk and locally overridden footprint are inconsistent. Model realignment is unsupported by the prescribed part-quality procedure; pad changes are explicitly outside this brief.
  • Completed: one internal quality report for OPA2990IDR, explicitly distinguishing the consuming-project override problem from its correctly aligned native source part. No duplicate reports for U2/U3, and no unsubstantiated defect reports for U6 or the SC-70 part.
  • Unattempted: manufacturing-pad edits, model workarounds/rebuilds, component movement/rotation, and routing. No safe silk-only correction resolves U1's contradictory actual-versus-required pin numbering.
Evidence table
Coordinates below use the owner's bottom-left board frame in mm: source = Flux + (40,24.5). Lead/mark findings are from native top/iso renders and source scene geometry, not guessed datasheet dimensions.

Table


Ref / exact sourceActual pad 1 / orderingSilk pin-1 consistencyModel lead alignment / model pin-1Result
U1 OPA2990IDR — sourceP1 (55.300,30.800), lower-left, not required (55.300,34.600). P1–4 ascend left row X55.3; P5–8 descend right row X60.7.Original composite silk remains horizontal, with circles near lower-left; it does not track the revised vertical-row footprint. Main exterior circle (55.35,29.93) identifies the current lower-left corner, not required upper-left. Another circle (56.09,31.93) is closer to P2 than P1; therefore ambiguous after pad overrides.Installed leads extend ±Y while pads are in ±X rows: 90° axis mismatch. Source model/render aligns with native ±Y-row footprint and shows model dot at lower-left (−X/−Y). Installed image does not resolve that recessed dot clearly; same unrotated model asset is used.Error: actual electrical ordering conflicts with owner requirement; model/silk are stale relative to project overrides. No pads or markers moved. One internal report filed.
U6 LM2903DR2G — sourceP1 (57.295,15.188), lower-left. Installed 90°: P1–4 left→right along Y15.188; P5–8 right→left along Y20.612.No dot in native silk: pin-1 bar at source X56.595, Y14.425…15.950, left of P1. Consistent with actual pin 1.Installed lead rows ±Y align with its 90°-rotated pads. Source top/iso clearly shows dot at local upper-left, matching native pad1; applying saved +90° maps it to installed lower-left. Installed flat render does not directly resolve the recessed dot, so installed marker orientation is transform-derived, not independently seen.No demonstrated model or silk orientation fault; unchanged.
U2 74LVC1G175GW,125 — sourceP1/CP (64.650,19.210), lower-left. P1–3 left→right at Y19.21; P4–6 right→left at Y21.19.Main exterior dot (64.02,19.21) lies left of P1; same corner. Extra imported comments-layer circle (64.65,18.85) is rendered with silk and overlaps P1 land; not a wrong-corner indication and not edited in this orientation-only scope.Installed ±Y lead rows align with ±Y pad rows; visible model dot lower-left agrees with P1. Source stores model rotation 0 0 -270; source render also aligns.Orientation verified; unchanged. Extra imported mark/copper overlap is noteworthy.
U3 74LVC1G175GW,125 — same source as U2P1/CP (64.650,16.110), lower-left. P1–3 left→right at Y16.11; P4–6 right→left at Y18.09.Main exterior dot (64.02,16.11) lies left of P1; same corner. Extra imported comments-layer circle (64.65,15.75) similarly overlaps P1 land.Same ±Y alignment and visible lower-left model dot as U2.Orientation verified; unchanged; no duplicate source report.
U1 critical contradiction — preserve for lead decision
The requested U1 pad1 at source (55.3,34.6) is currently pad4/V−, not pad1/OUT1. The requested left-row downward numbering and right-row upward numbering reverse the current sequence. This is not just a 3D mesh rotation problem: the current local pad overrides changed native rows and reversed their handedness relative to the stated target. Moving only a silk dot to the requested corner would falsely label pad4 as pin1.

Table


U1 pin / functionActual source coordinate
1 OUT1(55.3,30.8)
2 IN1−(55.3,32.07)
3 IN1+(55.3,33.34)
4 V−(55.3,34.6)
5 IN2+(60.7,34.6)
6 IN2−(60.7,33.34)
7 OUT2(60.7,32.07)
8 V+(60.7,30.8)
Saved U1 component transform is Flux (18,8.2), 0°, Top. Source part pads are native horizontal rows with pin1 local (−1.91,−2.77); source model has zero rotation and matches that native orientation. The present 90° model mismatch is therefore a project-override integration problem, not proof that the source library model is inherently rotated incorrectly. The quality report includes this distinction.
Other full pad ordering
U6: P1 (57.295,15.188), P2 (58.565,15.188), P3 (59.835,15.188), P4 (61.105,15.188), P5 (61.105,20.612), P6 (59.835,20.612), P7 (58.565,20.612), P8 (57.295,20.612). These values are transformed from exact source pad positions (±2.712, ±1.905/±0.635) and saved component transform (19.2,−6.6), 90°. Tiny render rounding (~0.01 mm) is not a placement edit.
U2: P1 CP (64.65,19.21), P2 GND (65.30,19.21), P3 D (65.95,19.21), P4 Q (65.95,21.19), P5 VCC (65.30,21.19), P6 MR (64.65,21.19).
U3: P1 CP (64.65,16.11), P2 GND (65.30,16.11), P3 D (65.95,16.11), P4 Q (65.95,18.09), P5 VCC (65.30,18.09), P6 MR (64.65,18.09).
Saved transforms remain U6 (19.2,−6.6),90°; U2 (25.3,−4.3),0°; U3 (25.3,−7.4),0°, all Top.
Render evidence
Installed U1

Installed U1 model versus pad rows

U1 source — native pads/model align

OPA2990 source alignment

Installed U6

Installed U6

U6 source — clear pin-1 mark and lead seating

LM2903 source top

LM2903 source isometric

Installed U2/U3

Installed U2 U3 alignment

SC-70 source

SC70 source alignment

Limitation / next decision
No supported part-model realignment was attempted under the mandated part-quality workflow; the manufacturing footprint must not be moved to match a mesh. U1 requires an explicit pad-numbering correction brief before pin-1 silk can be made unambiguous at the requested corner. U6/U2/U3 do not warrant source defect reports on the observed alignment evidence. The inspection is an orientation/geometry consistency check, not a new datasheet qualification or fabrication signoff.
  • Scope and disposition

  • Evidence table

  • U1 critical contradiction — preserve for lead decision

  • Other full pad ordering

  • Render evidence

  • Installed U1

  • U1 source — native pads/model align

  • Installed U6

  • U6 source — clear pin-1 mark and lead seating

  • Installed U2/U3

  • SC-70 source

  • Limitation / next decision