The one authorized auto-route run produced no new copper. Direct cleanup then reduced 56 → 53 airwires, preserving placement, rules, and frozen copper.
The updated routing report records remaining endpoints, individual blockers, DRC findings, and measurements. Zero-airwire completion was not achieved; P2 filled-area verification and final redundant-copper cleanup remain unfinished. The PCB is not fabrication-ready.
Assigned checklist batch documented; incomplete physical outcome; fabrication remains blocked. This continuation started at the previous ending 133 airwires (68 GND/65 other) and ends at 128 airwires (63 GND/65 other). No non-GND route was retried. No component, schematic, placement, mains, SW/VBST, isolation, outline or design-rule changes were made in this continuation. The sections below headed Archived earlier finishing pass are historical; their 133 counts, partial-via inventory and unavailable-measurement statements are superseded here.
Assigned-scope status
Table
Item
Status
Verified result / blocker
Four U1 vicinity GND vias
Completed geometrically
Four persisted 0.6/0.3 mm Top↔Bottom vias and local ties; global P2/P1 connectivity remains uncertified.
At least eight under-U5 GND vias
Completed geometrically
Eight persisted dedicated vias inside the module body and outside pad copper; not inferred from stitching-grid settings.
Every required outside-pour Top GND pad stitched
Failed / partial
27 retained stitch locations; six pads blocked as itemized below. Local stitches do not establish global fill/island continuity.
Existing Direct Connect selectors target nine U5 centre pads and C6/C11:P2; other-pad relief configuration retained. Native pad output omits effective thermal state; diagnostic export is not faithful thermal evidence.
Persisted route measurements
Completed diagnostically
SW, VIN, PWM_DIM, SETPOINT and two-net DIM+ series lengths below; SETPOINT fails its limit.
Actual P2 filled-area measurement
Completed diagnostically; required area failed
Final persisted filled contour is 26.615915 mm², below 30 mm². No pour enlargement or rule relaxation performed.
Full native checks
Completed; check failed
128 airwire errors, plus placement and manufacturing failures below.
Update this same report
Completed
This update preserves prior route attempts and the unchanged non-GND endpoint inventory as historical evidence.
Exhausted attempts were not repeated; accepted copper and 04bb escape preserved.
Actual retained ground geometry
Native readback shows 41 GND Smart Vias / 41 baked Via children, including 34 additional retained vias in this continuation and seven from the earlier pass. Baked children confirm 0.6 mm copper, 0.3 mm drill, Top↔Bottom. Tenting/mask geometry was not exposed by this readback and is not certified.
U1 four: (15.2,5.3), (16.0,5.3), (15.1,4.1), (16.3,4.1). The lower pair is tied to the original pair with 0.2 mm Top ground spurs. U1 pin 4 is (15.23,6.3); these are vicinity vias, not via-in-pad.
All new illegal trial geometry was removed: vias (34.6,−6.9), (35.0,−5.5), (37.606,−9.311), (11.844,23.039), and three redundant new spurs. Native checks initially found three copper overlaps and four via-in-pad errors; none remain. J4's own GND is explicitly permitted within its courtyard by the fully recovered rules; no via was placed in a TC2030 pad.
Six blocked outside-pour pads
Table
Pad / location
Specific failed or obstructed candidate
Q12:E (22.35,−1.75)
Candidate (23.15,−1.75): R52:P1/12V pad and 12V copper.
U3:GND (25.3,−8.39)
Candidate (26.1,−8.39): U3:D/MODE_SEL and R57:P1/Q_EN.
U2:GND (25.3,−5.29)
Candidate (26.1,−5.29): R59:P1/12V and U2:D/DIM_EN.
Q13:E (18.55,2.15)
Candidate (19.35,2.15): DIM_P_F and Q1_GATE copper.
D3:A (12.15,22.3)
Attempted via (11.844,23.039) removed for native via-in-pad. Nearby current copper also constrains an alternate.
Q9:S (37.3,−10.05)
Attempted (37.606,−9.311) removed for L3:W2_IN overlap/via-in-pad; revised (38.1,−10.05) blocked by corrected L3 bottom lands.
No pad, placement, keepout or clearance was altered to force these sites.
Ordinary centreline path; C9 branch 2.220 mm. Total ordinary SW copper 6.730 mm, below 10 mm, unchanged.
VIN C6:P1→U4:VIN
4.690 mm
Native three-piece sum: 0.325006 + hypot(2.449994,2.449994) + 0.899998 mm. Export graph shortcuts the pad-contained first piece and reports 4.364823 mm; that value is not used as complete centreline length.
PWM_DIM U5:IO3→R11:P1
1.903 mm
Below 15 mm; entire PWM_DIM net subtotal is not the requested stub.
SETPOINT C15:P1→U1:IN2+
14.657 mm
Fails ≤12 mm. Separate endpoint path, not whole star-net subtotal.
SETPOINT C10:P1→U1:IN2+
12.585 mm
Fails ≤12 mm. No obstructed R16 retry made.
DIM+ W4/J2 shared land→F2:1
6.869 mm
Includes persisted 0.170 mm pad-contained trace; graph alone reports 6.699432 mm. Excludes traversal within J2/W4 shared land.
DIM_P_PROT F2:2→D1:K
3.394 mm
Series second-net path.
DIM+ series copper subtotal
10.264 mm
Sum of the preceding two paths; excludes fuse internal conductor and shared-land traversal.
F2 topology resolved: schematic/net membership and exported pad positions agree: pin 1 at (23.55,11.4) is DIM+ from J2:1, pin 2 at (26.45,11.4) is DIM_P_PROT toward D1:K. Earlier Bottom SVG numbering was misleading; there is no verified topology reversal. Remaining drain-current and optional-choke topology gates are unaffected.
P2 actual baked contour: 26.615915 mm² on Top, bbox X7.093…16.000 / Y1.340…10.499. This is the final exported filled polygon area, not nominal 141.25 mm² outline, not board-wide exported zone outline, and not a KiCad-refilled result. The ≥30 mm² gate fails even on total P2 contour area; electrically attached U1 copper is not independently certified and cannot exceed that total. P3 contour area 65.531227056 mm²; P1 492.920657026 mm². P1/P2/P3 outlines and activation remain unchanged. Export frame: Flux X=KiCad X−53.359388, Flux Y=37.2915−KiCad Y.
Final checks and release gates
Full native review at 2026-10-06T13:53:39.353Z failed:
Design Rule Checks: 128 errors, all airwires; five warnings. Four pre-existing L3 terminal-geometry overrides and one explicitly preserved redundant 04bb group (11 nodes). No remaining introduced copper-overlap/via-in-pad errors or redundant GND spurs.
Placement: 22 errors / 24 warnings. Eleven keepout errors (C1, C2, C3, RV1, PS1, CY1, isolation slot) and eleven switching-power-stage errors. Warnings comprise nine body overlaps, one J1 edge finding, twelve decoupling findings and two power-stage findings. Shared-terminal/body-intent waivers are not a blanket approval of these categories. Frozen U4/C9/L2/C7/C11 geometry was not moved in this task.
No Signal Integrity category findings were returned; absence is not SI validation.
The live routing-state readback confirms 63 GND / 65 unchanged non-GND =128 opens. Ground stitching did not automatically connect all fill islands, U5 pads or buck returns: C6:P2→U4:GND remains open. This is not an electrically finished ground system. The final exact GND inventory follows; the archived non-GND inventory remains unchanged.
Additional outstanding gates: six blocked stitches; actual thermal/mask and island verification; P2 area and SETPOINT limits; ≥0.5 mm drain/current-path completion; all 128 opens; full placement/manufacturing findings; Gerber isolation/creepage audit; provisional PS1 lead/drill/land evidence; C1 lead-forming tooling; enclosure fit and screw-head height restrictions; live 1.50 mm stackup versus 1.6 mm ENIG baseline; pilot EMC and first-board functional tests. No manufacturing release implied.
Archived earlier finishing pass — historical, superseded where noted
Disposition
Incomplete; fabrication blocked. Live starting state was 132 airwires (67 GND/65 non-GND), not the obsolete 179 checkpoint. Ending state is 133 airwires (68 GND/65 non-GND). No non-GND connection closed in this pass. Two obstruction reroutes persisted and a GND tie initially reduced opens to130; applying required thermal relief elsewhere then exposed three additional ground opens. This is not a zero-airwire finishing result.
No component sourcing, placements, board-outline, isolation, mains, SW or VBST changes were performed. No whole-board autoroute or additional agents were used. Three successful targeted routing calls persisted, within the routing skill budget. Ground-via additions and removal of unsafe trial vias were separate primitive edits.
Authority and recovered evidence
Latest finishing-pass instruction explicitly permits first-pass12V/SETPOINT/DIM_SENSE obstruction ripup; no moves or clearance relaxation. Reused prior verified results, including accepted04bb escape and current-path topology caveat. Authority3 was re-read from https://cdn.flux.ai/project/chat/attachments/MeshDim-routing-authority-3-5a8dc5b2-aacc-423e-bd6b-2454e37fbd14. The rules-file web fetch returned incomplete excerpts; this pass relied on the persisted authoritative constraints and unchanged live rules rather than inventing missing text.
Coordinates below are Flux document millimetres, not source coordinates. Source=Flux+(40,24.5).
Item status and actual mutations
|Assigned item|Status|Evidence|
|Live recovery|Completed|132 starting opens; activeP1/P2/P3; accepted escape preserved.|
|DIM_SENSE obstruction relief|Completed locally|Removed first-pass831a9d… and atomically replaced its R17/R19 link,2.007758995mm at0.2mm. New tracec2919b06-b39f-4e94-ba87-29126763adc4. Its existing two opens remain.|
|12V obstruction relief|Completed locally|Removed first-pass555876… and replaced with4.797889702mm of0.5mm copper. Existing12V R59 open remains.|
|R16 SETPOINT obstruction resolution|Failed|Two distinct checked attempts, before/after DIM_SENSE reroute, failed. Original SETPOINT copper retained atomically.|
|R16 SINK_INT completion|Unattempted after concrete blocker|SETPOINT relief could not clear the corridor. Accepted04bb escape remains;R16:P2 open.|
|DIM_P_F ≥0.5mm drain connection|Failed|After12V reroute,0.5mm Q1:D↔L3:W1_OUT attempt still blocked. No thin sense spur accepted as drain-current completion.|
|DIM_N_F connections|Failed|R71↔C41 and R71↔L3 attempts both blocked; no copper persisted.|
|Ground stitches|Partial|12 trial vias added;7 illegal trial vias removed.5 manually placed legal vias retained plus2 new GND-route vias. Required4 nearU1/≥8 underU5 not achieved.|
|Solid/thermal configuration|Configured; baked-pad verification incomplete|Created explicit Direct Connect selectors for9 U5 centre pads and C6/C11:P2; Relief Connect on other pads. No width/clearance relaxation.|
|Each top GND pad outsideP2/P3 stitch|Unattempted|Remaining pad-by-pad geometry work not completed in bounded pass.|
|Full native DRC category check|Completed|Fresh final native DRC findings:133 airwire errors plus5 warnings; zero non-airwire copper errors in explicit checks.|
|Report|Completed|This single finishing-pass file.|
UnderU5 body outside pad copper: (36.5,−5.2),(36.5,−0.4),(29.3,−3.0) —3,not≥8.
Additional vias from22.403478939mm GND tie C11:P2→U5:GND2__13: (22.6,3.95),(27.475,4.775). Total retained newGND vias 7; second tie via is near the module upper edge, not counted toward the3 dedicated under-body stitches.
Rejected trial coordinates removed by exactUID: (14.4,5.3),(16.8,5.3),(36.5,−6.8),(36.5,−3.6),(36.5,−2.0),(36.5,1.2),(29.3,−1.0). Fresh checks showed16 overlap errors and2 via-in-pad errors from these; deletion resolved all18. Five zero-length traces generated by the tie call were deleted; retained vias and accepted04bb group untouched.
P3 fillStitchingDensity is now1.5mm×1.5mm. Read-back exposes only7 persisted SmartVias and their7 baked Via children, no additional generated stitching vias. Do not count grid intent as actual stitching. P3 retains Top-only connectedLayers; no unapproved polygon connection change was used to force stitching. P1/P2/P3 remain active and their outlines unchanged.
Warnings:4 pre-existing L3 terminal geometry override rows W1_IN/W1_OUT/W2_IN/W2_OUT at module-option footprint centre(36.8,−7.5);1 explicitly preserved04bb SINK_INT redundant group11nodes nearR16/local escape. No remaining new redundant ground stubs.
Body-check waivers from prior authority were not re-certified here; native copper checks are not a Gerber isolation/spacing audit or complete electrical release signoff.
R16: failed SETPOINT replacement endpoints R16:P1(6.025,10.6)→existing trace3b8334… at(9.216,12.266). Cheapest path crossesR19:P1/DIM_SENSE, newc2919b…DIM_SENSE copper and the intentionalTopJ4 courtyard. R19 pad cannot be removed in copper-only scope; SETPOINT original remains connected. SINK_INT residual is trace8947cdd7…→R16:P2(4.375,10.6). Beware raw Bottom SVG pin-name orientation: pathfinder physical pad locations used here, not swapped SVG labels.
DIM_P_F current: residual first-pass via791f50…↔trace17c88bd2… . After12V relief, blockers are new12V traces46095455… and988e7d29… onTop plusC10:P1/SETPOINT onBottom. Candidate starts on0.2mm sense copper(20.925,9.9),via region(18.925,10.9),Top(17.675,12.15…13.65)→(25.425,14.4)→existing via(23.642,9.488). Merely completing this nearest-island path would NOT prove≥0.5mm all the way toQ1 drain. Wider direct current topology still required.
DIM_N_F: R71:P2↔C41:P1 blocked byDIM_FB_ADC/VRAIL_ADC, newGND tie via near(27.475,4.775), andR70:P1; R71:P2↔L3:W2_OUT blocked byAUX_ADC vias/traces,12V trace2450a9…,moduleNCpad andL3 opposite-net pad. No retries on unchanged geometry were made.
Exact remaining non-GND endpoint inventory
First-pass object aliases below use their unique suffix; full prefix is autoRouted.auto-layout-ab8e60ae-ee75-4e04-9c5e-b85315fb9709.<netUID>.Trace.<suffix> (orSmartVia suffix as marked). Endpoints are the final routing_state findings, not proposed routes.
-3V3:trace86376a44b0fd3534d0f0af654c52d300→R39:P1.
-12V:R59:P1→trace65db3cae7d9f92645523257c19c29843.
-AUX_ADC:U5:IO1→traceb4d0fe7e6542e22b21b52bfe87fafa85.
-BTN_USER:U5:IO9↔TP18:P1.
-DF_E:Q2:E↔R64:P1.
-DIM_EN:R31:P2↔U5:IO8.
-DIM_FB_ADC:via6b856ee17674a969a3982f97b0b46aef→D4:C/A;TP19:P1→trace277b8cf9420990a25e6fd5c237b971cb.
-DIM_LATCH:U3:CP↔U2:CP;U5:IO14↔R34:P1;U5:IO14↔U2:CP.
-DIM_N_F:R71:P2↔C41:P1;R71:P2↔L3:W2_OUT.
-DIM_P_F:via791f50f85f5db4ca0b0fbefb5f565e5e→trace17c88bd2-8b62-46d4-a975-9587894f5274.
-DIM_SENSE:tracec2919b06-b39f-4e94-ba87-29126763adc4→R20:P1;R15:P2↔R20:P1.
-DIM−:trace4194a936a4fa274168515a916d54c0aa→L3:W2_IN;TP14:P1→padc7bf1b86-b99b-424a-8bed-94aa4f8e14c0__2a1355d6-05f1-4808-8eea-46182e61ee75.
-EN_HALF:U6:INPUTS_B_2→trace341570c36066f4fd04f6cb6c63ad0abf.
-EN:traceb02ae09c913675f599af32475cdf5043→TP17:P1.
-EXP_INT:J3:Pin_5↔U5:IO22;U5:IO22↔R36:P1.
-I2C_SCL:trace2f04e2a330a1bd5b0af73ed76a9b32bd→J3:Pin_4.
-I2C_SDA:J3:Pin_3↔U5:IO6;R39:P2↔U5:IO6.
-LATCH_CLR_N:C22:P1→traced42701d5737b7bf6830ef3e3f146b0a9;TP22:P1↔C22:P1;U3:~MR→trace0c317da30488696edb83865e2423243d.
-LED_STAT_G:U5:IO20↔R41:P1.
-LED_STAT_R:U5:IO21↔R42:P1.
-MODE_NET:U6:INPUTS_B_1↔R56:P2.
-MODE_SEL:U3:D↔U5:IO19;U5:IO19↔R35:P1.
-NTC_ADC:U5:IO2→tracecb7ca009a573843a2f80e3551135d747.
-PWM_RC1:R11:P2↔C14:P1;R11:P2↔R12:P1.
-Q_EN:D6:K::1↔R57:P1;TP11:P1↔U2:Q;U2:Q↔R57:P1.
-Q_MODE:TP12:P1↔R53:P1;U3:Q↔D6:K::2;U3:Q↔R53:P1.
-Q1_GATE:trace01e8feb0-cc68-4586-84cb-ffbb4175c41a→trace7628a8bc60830e3daae7b72dc28cb2bb.
-Q1_SRC:R10:P1↔Q1:S;R10:P1↔R72:P1.
-Q9_D:R46:P2↔Q9:D.
-Q13_B:Q13:B↔R72:P2.
-RELAY_RST:TP3:P1↔U5:IO23;U5:IO23↔R38:P1.
-RELAY_SET:R37:P1↔U5:IO18.
-SINK_DIS_12V:traceb8362d5d61da03276d9829db31783296→U6:OUTPUT_B.
-SINK_FB:trace6c67034f-1b47-4988-af45-3a35660d7d6f↔R18:P1;C17:P1↔same trace;Q12:C→trace89778b5f-e853-4dc9-a435-9341bceefadd.
-SINK_INT:trace8947cdd7-423d-45ea-b5d4-a5551594d96e→R16:P2.
-SINK_OUT:trace6fb9ab9b3220e2ca4bb664a8dbd86b67→R44:P1.
-SPARE_IO15:TP2:P1↔U5:IO15.
-SRC_DIS_12V:trace3d13b4ee8f2f907a6aa021d608d9ff80→D10:2.
-TP7_NET:R68:P2↔TP7:P1.
-UART0_RXD:trace8cf52d15b70db1cfb92beb69cb738f4b→U5:RXD0.
-UART0_TXD:TP15:P1↔U5:TXD0.
-USB_DM:U5:IO12↔J5:PIN_2.
-USB_DP:U5:IO13↔J5:PIN_3.
-VRAIL_ADC:trace0ecfc207c280bd0173612e6f48f050a5→U5:IO5.
-ZC_DET:TP1:P1↔R33:P2.
Unavailable measurements are not certified. The current board still has too many opens for release.
SW: live ordinary segment centreline subtotal 6.73003mm (five0.55mm segments fromU4:SW(8.100001,2.4) toL2:1(11.2,1.8), plus0.8mm segment(10.8,3.3)→C9:P2(10.8,5.52)). Exact subtotal expression: 2.22 + sqrt(2)*0.739148 + 1.159129 + 0.800072 + 0.937498 + sqrt(2)*0.401650. This is exposed ordinary-trace geometry, not a certified complete topology-aware SW length, since other shape/neckdown copper may connect branches. No SW edits made.
VIN definition: local12V feed fromC6:P1 toU4:VIN(7.15,5.0), rather than whole12V net total. Exact routed endpoint-path length unavailable in this pass; not substituted with straight-line distance.
SETPOINT stub definition: local hold/filter connection C15:P1→U1:IN2+(20.77,6.3), and separately C10:P1→that junction. Neither exact branch length measured. R16 branch remains obstructed and original SETPOINT copper retained.
PWM_DIM stub definition: U5 PWM_DIM terminal→R11:P1(32.35,5.575 nominal pathfinder/5.58 rounded SVG). Exact MCU terminal mapping and topology-aware branch length not extracted here; unavailable, not a PWM_RC1 length substituted.
DIM+ series requirement: J2:1→F2 input, then F2 output→D1:K(26.41,11). Potential existing topology reversal requiring owner verification: SVG shows DIM+ copper fromJ2/W4 at(26.45,16.5) via(24.52,14.4) toF2:2(23.55,11.4), whereasF2:1 is(26.45,11.4). Do not infer input/output from physical numbering or claim J2→F2→D1 topology without netlist verification. F2 series element makes this a two-net path(DIM+/DIM_P_PROT),not one DIM+ net length. Exact full path length unavailable; optionalL3/R70 link and Q1 current bottleneck remain release gates.
P2 baked filled area: unavailable. Nominal outline12.5×11.3=141.25mm² atcentre(9.75,4.85) is not the filled area. Scene-tree exposes a bakedFill child but no usable filled polygon contours/area in the returned data. No nominal area presented as measured filled copper.
Fabrication gates
Close133 remaining connections and recheck. Native clearance/short check success does not make an unrouted board functional.
Complete≥0.5mm Q1 drain/R14 current path independently of0.2mm sense spur continuity; verify DIM+J2→F2→D1 topology and both optional-choke assemblies.
Complete4 U1 stitches,≥8 verified underU5 and every required outside-pourTopGNDpad stitch. Verify all fills connected and thermals robust.
Obtain actual baked pad-thermal readback,P2 area and topology-aware lengths; inspect final copper/isolation in manufacture exports.
PS1 PBO-3F-12 drill/land geometry remains provisional/TBC: manufacturer lead cross-section and recommended drill/land geometry unavailable. Vendor or measured evidence required; no production hole-size approval in this pass.
C1 horizontal formed-lead assembly tooling validation,80×49 enclosure fit, screw-head height restrictions and2-layer1.6mm/ENIG production stackup reconciliation remain existing gates. Live standard stackup description reports1.50mm label; do not silently equate with1.6mm production requirement.
Native DRC findings above do not replace safety/isolation clearance/creepage audit,protection coordination,EMC pilot,manufacturing-file validation or first-board functional testing.
The bounded local work was performed and documented; the overall finishing request remains failed/incomplete, not fabrication-ready.
Current checklist disposition — 2026-10-06
Assigned-scope status
Actual retained ground geometry
Six blocked outside-pour pads
Final persisted measurements
Final checks and release gates
Archived earlier finishing pass — historical, superseded where noted