Project Start


Worked for 1 hr
Thought for 13 sec
Referenced guidance.
Thought for 21 sec
Board check: 22 issue(s) found
Thought for 25 sec
Reading PCB Placement Handoff's report…
Thought for 21 sec
Routing paused
Thought for 28 sec
Thought for 17 sec
Checking routing progress.
Thought for 24 sec
Awaiting 1 task
"PCB Placement Handoff" completed.
Thought for 1 hr 23 mins
Thought for 23 sec
Managing 1 task
Thought for 25 sec
Thought for 22 sec
Awaiting 1 task
Thought for 20 sec
Awaiting 1 task
"PCB Placement Handoff" completed.
The one authorized auto-route run produced no new copper. Direct cleanup then reduced 56 → 53 airwires, preserving placement, rules, and frozen copper.
The updated routing report records remaining endpoints, individual blockers, DRC findings, and measurements. Zero-airwire completion was not achieved; P2 filled-area verification and final redundant-copper cleanup remain unfinished. The PCB is not fabrication-ready.

Bounded Routing Gate Correction
Result — 2026-10-05
Partial batch completion; not ready for autorouting. No routing, sourcing, component moves, pad-geometry changes, board/slot/hole changes, or exports were performed. U1 was left untouched. The 80×49 mm board and Standard 2 Layer stackup were preserved; this pass did not change the specified ENIG finish or certify fabrication.
Authority: latest 11-item user disposition. This report supersedes only routing-gate status in the earlier U1/restoration report. Coordinates below are the user's source frame; Flux = source − (40,24.5) mm.
Assigned-scope disposition

Table


ItemStatusEvidence / specific blocker
DIM_P_PROT replaces obsolete SRC_PTC in DIM rulesCompletedVerified live F2:2–D1:K net UID 758f2608-4fa8-4e1f-ad13-23479434a275. Updated width and analog-separation rules; no schematic rename.
DIM width 0.5 mmCompletedAll eight DIM nets plus existing 12V selected in Rev C5 power and DIM widths. DIM_P_PROT computed minimum/preferred width both 0.5 mm.
GND minimum 0.2 mmCompletedNew GND rule; computed minimum/preferred widths both 0.2 mm.
U5 minimum fanout 0.2 mm; withdraw 0.15 mm clearance exceptionCompleted for width/clearance declarations23 connected U5 signal nets have 0.2 mm floor; U5 pad escape rule 0.2 mm. Sample EN computed width/minimum both 0.2 mm. GND 0.2 and 3V3 0.3 retained. Length, internal-via topology and stitches remain routing-pass work.
Region S net-selective exclusion with PS1/CY1/FID1 exceptionsFailed / tool-capability blockedNo safely verified net allow/block list or exact-pad exemption interface. Full Region S was not represented by a misleading blanket keepout.
Region M net-selective exclusion and PS1 pin-4 exceptionFailed / tool-capability blockedSame limitation; full Region M was not authored. Existing four isolation-gap zones retained, not claimed equivalent to S/M.
Top RV1/C1 housing exclusions including own-pad exemptionsFailed / incompleteExact existing Top rectangles retained and read back. Correct own-pad exemption and router enforcement not established; RV1 tips intrude 0.1 mm.
Only three specified mains intra-footprint waiversCompleted as documented disposition; native enforcement failedJ1 1↔2, PS1 1↔2, PS1 3↔4 only. Six directional exact-pad rules were attempted, failed preflight, then fully deleted. Global mains isolation was never relaxed.
Make all four omitted PS1 pins accessible without changing pads/isolationFailedFinal preflight still excludes PS1 pins 1,2,3,4. Also actual PS1 pin2↔3 gap is 2.4 mm and is not one of the three authorized waivers.
Reconcile TP24 conflict without bypassing isolationCompleted diagnosis; physical remediation blockedTP24 GND is outside Region S/barrier and allowed by Region M, but its copper overlaps J4's left locator drill by approximately 0.056 mm. Fixed placement/geometry constraint prevents repair here. No keepout was bypassed.
Preserve buck/J4 guidance, shared pads, positions and geometryCompletedNo component/pad/board mutation; four same-net shared-pad warnings remain intentional. Guidance preserved below.
Preflight and evidenceCompletedTwo focused iterations, below the three-run cap. Final 170 components/87 nets, nine Warnings + one Info; separate check has ten keepout Errors.
Autorouting, neckdowns, pours, stitches, lengths, silk, fabrication deliverablesUnattempted by bounded briefLead owns routing and subsequent passes.
Persistent rule changes and verified coverage
Final ruleset readback contains 63 named rulesets versus 60 at entry: three new rulesets, three existing rulesets updated, and no retained peer-waiver experiment.

Table


RuleUIDFinal coverage
Rev C5 power and DIM widths — updatedc3429b44-602f-440b-9a97-ecf2c46d8ab912V; DIM+, DIM−, DIM_P_F, DIM_N_F, DIM_P_PROT, DIM_SENSE, SRC_R, Q9_D. Minimum and preferred 0.5 mm.
Rev C5 analog class separation — updated24fde684-831b-4b75-8038-c32dbb939227Existing 16 ANALOG nets to SW/VBST/12V and eight DIM nets at 1 mm, including newly added DIM_P_PROT; 0.2 mm base. Pair-selector persistence is not proof of router enforcement.
Rev C5 default copper clearance — description updated1b1fe420-c52d-4a9c-984d-36d9d2623272Existing 0.2 mm unchanged, including U5. Obsolete pending 0.15 mm exception removed from description. HOLE pads remain excluded to retain actual hole/slot restrictions.
Rev C5 GND routing minimum — newac8790de-b702-44f7-a638-573e7d81dbe0GND minimum/preferred 0.2 mm; computed readback confirms both.
Rev C5 U5 signal net width floor — newd7156cec-b542-4a5d-842d-7475c5bdb0a423 U5 signal nets, minimum 0.2 mm, listed below.
Rev C5 U5 pad fanout minimum — new9935cad0-a722-44e4-aa6d-ebfb319cc050U5 pads, 0.2 mm minimum/preferred escape declaration.
The 23 signal nets are EN, DIM_FB_ADC, AUX_ADC, NTC_ADC, PWM_DIM, ZC_DET, VRAIL_ADC, I2C_SDA, I2C_SCL, DIM_EN, BTN_USER, UART0_TXD, UART0_RXD, USB_DM, USB_DP, DIM_LATCH, SPARE_IO15, RELAY_SET, MODE_SEL, LED_STAT_G, LED_STAT_R, EXP_INT, RELAY_RST. Unconnected U5 NC nets were not added; GND and 3V3 have their separate rules. An initial all-net 0.2 mm floor introduced an unrelated Q2: E / DF_E exclusion; it was narrowed to these 23 U5 signals, and that exclusion disappeared.
Computed-width spot checks after final changes: DIM_P_PROT 0.5/0.5 mm minimum/preferred; GND 0.2/0.2; EN 0.2/0.2; 3V3 0.3/0.3; 12V 0.5/0.5; SW 0.5/0.8. Newly observed pre-existing discrepancy: L and N retain their saved inline and named-rule 1.5 mm declarations, but both computed minimum/preferred values read 1.0 mm. This pass did not modify those rules; do not assume the existing 1.5 mm intent is effective. It needs precedence reconciliation before routing those traces.
Other saved declarations remain: mains 3.0 mm floor, mains-track 3.2 mm separation, mains no-pour/direct-connect, widths/layer rules, fiducials, via sizes/tenting, hole and slot keepouts. Their persistence is not a certification of router enforcement or IEC compliance.
Regional coverage: exact distinction between required and implemented
Full requested S/M are not implemented. Available zone/rule schemas expose geometry, layers and keepOut/minKeepOut as selector-to-distance lists, but no verified binary per-net exclusion with an allowed-net/allowed-pad list. Three help-documentation searches did not establish such support. A distance of zero is not an exemption from occupying a keepout. Therefore no negative-distance tricks, fake net attributes, globally disabled isolation, or blanket regions with claimed exceptions were used.
Required geometry retained here for the lead:
  • S: no non-MAINS tracks/vias/pours/pads on either layer in X0–41.5/Y3.5–46, X0–46.5/Y0–3.5 and X0–46.5/Y46–49. Exact exceptions: PS1 pads, CY1 pads, FID1.
  • M: no MAINS copper on either layer in X37–80/Y6–46, X30–80/Y0–6 and X33–80/Y46–49. PS1 pin4 pad exception, or user-authorized boundary step X37.6 between Y17 and19.5.
  • Barrier: X38–41 remains copper-free except PS1/CY1 pads.
Only these existing regional primitives are persisted; all were preserved unchanged:

Table


Source bounds, mmLayer declarationUID
X37–41.5, Y3.5–46All8ca1da9b-dc0d-445e-9f52-98e3ac1bdd20
X30–46.5, Y0–3.5All8ad47d4f-6002-4d05-8fc9-4beb6d7730c4
X30–41.5, Y3.5–6Alla3870597-81f5-46f6-a231-cee1e00f4093
X33–46.5, Y46–49All59b900b8-b7d7-4e99-8fd1-a52c3d5cb9cc
RV1 X8.25–25.25, Y25.5–47.5Topc1424fcd-b3e9-4b52-bbbb-a42e64176edd
C1 X27.25–38.25, Y27.5–49Top8636e1b7-3dd5-4daa-893d-6651b888e6d8
These use zero-margin pad/via/routeSegment/polygon/fill exclusions and the existing named rulesets ba659314-3d8a-4a63-b8a3-bd32e2bf7fe1 / 85691e10-a509-4c4e-b33f-aa56e40fc76d. Readback establishes stored geometry and layer intent only. The gap rectangles cover portions of the overlapping forbidden regions, not all S or M, and do not enforce the net-selective primary-area restriction. The Top housing rectangles have no implemented host-pad exemption. No claim of full reinforced isolation or creepage compliance is made. A supported selector-aware region/waiver capability needs confirmation from Flux engineering before this can be considered a native autorouter-ready constraint set.
PS1: precise remaining exclusion and unauthorized fourth pad pair
Current pads remain unchanged: centers X23.2,27.2,31.2,35.2,43.2,47.2, all Y18.2; readback copper diameter 1.6 mm. The user MD instead describes VCAP centers X32.6/36.6 and 2.2 mm edge gaps. No footprint repair or drill change was made. Provisional drills gate fabrication only, not the reason for withholding routing here.
For actual pin2/pin3, pitch is 4.0 mm and copper-edge gap is 4.0−1.6 = 2.4 mm, below retained 3.0 mm net clearance. Pin2↔3 was not waived by the latest instructions. Even a working implementation of the three permitted waivers cannot silently waive this additional pair.
Attempt: six directional exact-pad selector rules, permitting only J1 1↔2 at 2.6 mm and PS1 1↔2 /3↔4 at 2.2 mm, with 3.0 mm to other copper and 3.2 mm to tracks. All four PS1 exclusions persisted and extra keepout-ignore warnings appeared. All six experimental rulesets were deleted; final readback verifies absence. Merely storing these selectors did not solve router accessibility, and no broader clearance relaxation was attempted.
TP24: not an S/M geometry error
TP24 P1 is GND at source (44.8,39.4), diameter 0.5 mm. Its left copper edge X44.55 is 3.05 mm beyond S's X41.5 boundary at this Y; Region M permits GND here. It is outside the barrier band and all six listed copper rectangles.
However, J4's left locator NPTH is at source (44.46,40.0), diameter 0.991 mm (2D drill geometry corroborates approximately 0.99 mm). Center distance is about 0.689638 mm; radii sum 0.7455 mm. Calculated copper-to-drill gap is −0.055862 mm, an approximately 0.056 mm physical overlap, before any hole clearance allowance. Locator node: 78192cdd-7400-42f2-893a-dc5b76b5c4e5__185e7a27-7b96-48a4-951e-0be88bd24feb.defaultFootprint.mounts.a9b47f4119d0eaf040f1f477d6d001a1.
Preflight does not identify the offending keepout UID, so its exact diagnostic source cannot be proven from that response alone; this independently verified drill collision is nevertheless genuine. Shrinking S/M, removing the locator keepout, or acknowledging a waived height envelope would not fix it. No placement/pad/drill change is authorized in this batch.
Verification and residual counts
Two preflight iterations, no autorouting:
  1. After compatible width and six peer-waiver mutations: 170 components/87 nets; 31 Warnings = four intentional shared-pad entries + 22 pins inside ignored keepouts + five excluded pins (PS1×4, Q2:E/DF_E). One Info empty GND plane.
  2. After deleting all six failed peer-waiver rules and restricting the broad width floor to U5 signals: nine Warnings = four intentional shared-pad entries + one ignored-keepout pin + four excluded pins. One Info empty GND plane. No Error-severity entry in preflight itself.
Final excluded pins, exact identities:

Table


PinNetPreflight consequence
PS1:1 AC(L)L_CHOKERemoved from routing
PS1:2 AC(N)N_CHOKERemoved from routing
PS1:3 +V(CAP)VCAP_PRemoved from routing
PS1:4 −V(CAP)VCAP_NRemoved from routing
Additional final warning: TP24:P1 / GND inside a keepout; router says that keepout will be ignored. Intentional merges: J1:2/W3 on N; J1:1/W2 on L; J2:1/W4 on DIM+; J2:2/W5 on DIM−. No different-net-overlapping-pad warning was returned. Advisory Info: GND plane layer0 has no area after filling.
Separate read-only keepout/invalid-layer/overlapping-copper check, reviewedAt 2026-10-05T12:45:17.223Z, returned ten Keepout Violations Errors: C1×3, C2×1, RV1×2, PS1×1, CY1×1, isolation-slot object×2. These are placement-zone checks rather than proof of correctly net-selective copper enforcement. No matching invalid-layer or overlapping-copper item was returned in that filtered response. Error means wrong; Warning means possibly wrong; Info means noteworthy. Pin-drop/keepout-ignore warnings remain operational blockers despite Warning severity.
Guidance preserved for the routing lead
  • Buck pocket Top X44–52/Y24–31: only SW,GND,3V3,12V,VFB,BUCK_EN; guidance, not newly encoded DRC.
  • J4 courtyard: only 3V3,GND,UART0_TXD,UART0_RXD,EN,BTN_USER; guidance. This does not waive its physical locator holes.
  • GND bottom power regions, top buck hot-loop pour, both-layer U5 pour, 0.6 mm slit at X50/Y30.5–37 bridged Y37–38 and >=8 U5 GND stitches remain routing-pass requirements, not performed here.
  • U5 fanout 0.2–0.3 mm, =1.0 mm to edge / N >=3.5 mm from the (4,4) hole center remain explicit verification requirements. Existing board-inset rule is only a fill proxy at 0.5 mm, not complete edge DRC.
  • User closes intended J1 body overhang, D15 height inside J4 plug envelope, mains-side underside QR and final buck placement. None appears as an additional final preflight exclusion. The ten general zone-check errors are separately listed, not silently waived.
  • No source research repeated. Internal feedback submission failed; no ticket was filed.
Lead handoff: supported width changes are committed and read back; S/M enforcement, housing exceptions and PS1 accessibility are not complete. TP24 has an actual drill conflict rather than an isolation-region boundary error. Do not treat this batch completion or the nine-warning preflight as permission to launch unconstrained routing.
  • Result — 2026-10-05

  • Assigned-scope disposition

  • Persistent rule changes and verified coverage

  • Regional coverage: exact distinction between required and implemented

  • PS1: precise remaining exclusion and unauthorized fourth pad pair

  • TP24: not an S/M geometry error

  • Verification and residual counts

  • Guidance preserved for the routing lead