Power Conversion Board Design


Good plan. I’d make it a single internal power box with two isolated compartments:

Text


[ Compartment A: Low-voltage adapter PCB ]
ATX input, +24V DC-DC, +5V, -5V, fuses, Shugart DC connector

[ Barrier / air gap / internal wall ]

[ Compartment B: Enclosed inverter module ]
12V input, 115VAC 60Hz pure-sine output to Shugart spindle motor
I recommend an off-the-shelf aluminium enclosure over 3D print if it fits:
  • Better fire resistance
  • Better EMI shielding
  • Easier chassis/earth bonding
  • Better heat spreading
  • More mechanically robust
3D print is acceptable only if you use a suitable flame-retardant material and keep the inverter fully enclosed/insulated internally, but typical PLA/PETG is not ideal near power electronics.
Design rules I’d use:
  • Keep AC wiring physically separated from DC wiring.
  • Use grommets/strain relief where wires pass through walls.
  • Use covered terminals for 115VAC.
  • Add labels: 115VAC 60Hz, Hazardous Voltage, Disconnect PSU before opening.
  • Bond aluminium enclosure to PC chassis/earth if metal.
  • Keep the inverter module’s AC output floating unless its documentation says otherwise.
  • Put the low-voltage PCB and inverter on separate mounting standoffs.
  • Add ventilation near the inverter, but avoid finger-accessible openings near AC.
Next schematic/layout direction: treat the Flux PCB as the low-voltage adapter/control board, with a fused 12V output connector feeding the separate inverter compartment and a 115VAC output connector/wiring path clearly labeled as coming from the inverter module.
It's quite common to put Meanwell PSUs in 3d printed cases
Yes — it’s common, and it can be acceptable, but I’d separate the cases:
Mean Well PSU in a 3D-printed case is usually safer because the hazardous mains section is already inside a certified metal/plastic PSU enclosure. The printed case is mostly a secondary cover or mounting shell.
For your project, the equivalent safe approach is:
  • Use a commercial enclosed pure-sine inverter module as the hazardous-voltage device.
  • Put that enclosed module inside your larger 3D-printed “single box.”
  • Keep the Flux PCB as the low-voltage adapter board in a separate compartment.
  • Do not expose bare 110VAC PCB terminals or a bare custom inverter board inside a normal PLA/PETG box.
So I’m not against a 3D-printed outer enclosure. I’m against relying on a normal printed enclosure as the primary safety barrier for a custom bare high-voltage inverter.
If you 3D print it, I’d use:
  • Flame-retardant filament if available, ideally UL94 V-0 rated material
  • Internal divider wall between inverter and low-voltage board
  • Heat-set inserts/standoffs
  • Strain reliefs/grommets
  • No exposed AC screws
  • Warning labels
  • Ventilation that does not allow finger/tool access to AC wiring
A printed case around an already enclosed inverter module is reasonable. A printed case around a bare 170VDC/115VAC inverter PCB is where I’d draw the line.
Update schematic and docs
Use enclosed inverter
Rename AC nets
Add safety documentation
Run design checks

Shugart 800 ATX PSU Power Architecture
Requirements
  • Input: standard ATX PSU rails
    • +12 V: 46 A / 552 W available
    • +5 V: 25 A, shared with +3.3 V limit of 130 W
    • +3.3 V: 25 A
    • -12 V: 0.8 A / 9.6 W
    • +5 VSB: 3 A / 15 W
  • Outputs required for Shugart 800 motor and board/controls:
    • 110 VAC 60 Hz pure sine, 30 W motor load
    • +24 VDC at 1.3 A = 31.2 W
    • -5 VDC at 0.25 W = 50 mA
    • +5 VDC at 1 A = 5 W
Current architecture: EGS002-controlled inverter carrier
The user requested an EGS002 board. The EGS002 is an EG8010 + IR2110S sinusoidal inverter driver board, not a complete 12 VDC to 110 VAC inverter module. This project now treats the PCB as a protected ATX distribution board and EGS002 controller carrier.
  • +12 V ATX rail feeds:
    • fused high-current 12 V feed for an external MOSFET H-bridge / transformer inverter power stage controlled by U3 EGS002
    • 12 V to 24 V boost converter module rated at least 40–50 W
  • +5 V output uses the native ATX +5 V rail, fused for the Shugart logic/control load and also powers the EGS002 +5 V input
  • -5 V output is derived from the ATX -12 V rail using the LM79L05 regulator, sized for the stated 0.25 W / 50 mA load
  • 110 VAC output terminal J2 is the hazardous AC output from the external transformer/output-filter stage, not directly from the EGS002 board
EGS002 interface nets
U3 EGS002 is connected to:
  • +12V_INVERTER: EGS002 +12 V driver supply and fused inverter-stage 12 V feed
  • +5V_OUT: EGS002 +5 V logic supply
  • GND: common low-voltage return
  • EGS002_1LO_GATE, EGS002_1HO_GATE, EGS002_VS1_SWITCH: one half-bridge gate/switch-node interface
  • EGS002_2LO_GATE, EGS002_2HO_GATE, EGS002_VS2_SWITCH: second half-bridge gate/switch-node interface
  • EGS002_IFB_CURRENT_FEEDBACK: current feedback input; overcurrent trip is typically around 0.5 V at IFB
  • EGS002_VFB_VOLTAGE_FEEDBACK: AC output voltage feedback input
  • EGS002_TFB_TEMP_FEEDBACK: temperature feedback input; overtemperature trip is typically around 4.3 V
  • EGS002_FANCTR: fan-control output
Current budget estimate from +12 V rail
  • 24 V rail: 31.2 W / ~88% efficiency ≈ 35.5 W input ≈ 3.0 A from +12 V
  • 110 VAC motor load: 30 W / ~85% inverter-stage efficiency ≈ 35.3 W input ≈ 3.0 A from +12 V, plus motor start surge
  • Total +12 V steady estimate: about 6 A, well below the 46 A PSU rating, but the H-bridge, transformer, wiring, connector, and fuse must be sized for surge current.
Safety notes
  • 110 VAC is hazardous. The board must maintain high-voltage creepage/clearance, physical separation, clear silkscreen labels, and an enclosure.
  • EGS002-based inverter designs require correct H-bridge MOSFET selection, gate routing, transformer ratio/power rating, output filtering, feedback scaling, current sensing, thermal sensing, fusing, and bring-up with an isolation transformer/current-limited supply.
  • This revision is no longer a certified-inverter-module carrier; it is a custom inverter-controller carrier and therefore has higher safety and validation risk.
  • Requirements

  • Current architecture: EGS002-controlled inverter carrier

  • EGS002 interface nets

  • Current budget estimate from +12 V rail

  • Safety notes