Power Conversion Board Design


Good plan. I’d make it a single internal power box with two isolated compartments:

Text


[ Compartment A: Low-voltage adapter PCB ]
ATX input, +24V DC-DC, +5V, -5V, fuses, Shugart DC connector

[ Barrier / air gap / internal wall ]

[ Compartment B: Enclosed inverter module ]
12V input, 115VAC 60Hz pure-sine output to Shugart spindle motor
I recommend an off-the-shelf aluminium enclosure over 3D print if it fits:
  • Better fire resistance
  • Better EMI shielding
  • Easier chassis/earth bonding
  • Better heat spreading
  • More mechanically robust
3D print is acceptable only if you use a suitable flame-retardant material and keep the inverter fully enclosed/insulated internally, but typical PLA/PETG is not ideal near power electronics.
Design rules I’d use:
  • Keep AC wiring physically separated from DC wiring.
  • Use grommets/strain relief where wires pass through walls.
  • Use covered terminals for 115VAC.
  • Add labels: 115VAC 60Hz, Hazardous Voltage, Disconnect PSU before opening.
  • Bond aluminium enclosure to PC chassis/earth if metal.
  • Keep the inverter module’s AC output floating unless its documentation says otherwise.
  • Put the low-voltage PCB and inverter on separate mounting standoffs.
  • Add ventilation near the inverter, but avoid finger-accessible openings near AC.
Next schematic/layout direction: treat the Flux PCB as the low-voltage adapter/control board, with a fused 12V output connector feeding the separate inverter compartment and a 115VAC output connector/wiring path clearly labeled as coming from the inverter module.
It's quite common to put Meanwell PSUs in 3d printed cases
Yes — it’s common, and it can be acceptable, but I’d separate the cases:
Mean Well PSU in a 3D-printed case is usually safer because the hazardous mains section is already inside a certified metal/plastic PSU enclosure. The printed case is mostly a secondary cover or mounting shell.
For your project, the equivalent safe approach is:
  • Use a commercial enclosed pure-sine inverter module as the hazardous-voltage device.
  • Put that enclosed module inside your larger 3D-printed “single box.”
  • Keep the Flux PCB as the low-voltage adapter board in a separate compartment.
  • Do not expose bare 110VAC PCB terminals or a bare custom inverter board inside a normal PLA/PETG box.
So I’m not against a 3D-printed outer enclosure. I’m against relying on a normal printed enclosure as the primary safety barrier for a custom bare high-voltage inverter.
If you 3D print it, I’d use:
  • Flame-retardant filament if available, ideally UL94 V-0 rated material
  • Internal divider wall between inverter and low-voltage board
  • Heat-set inserts/standoffs
  • Strain reliefs/grommets
  • No exposed AC screws
  • Warning labels
  • Ventilation that does not allow finger/tool access to AC wiring
A printed case around an already enclosed inverter module is reasonable. A printed case around a bare 170VDC/115VAC inverter PCB is where I’d draw the line.
Update schematic and docs
Use enclosed inverter
Rename AC nets
Add safety documentation
Run design checks

Safety and Compliance Notes
This board distributes power from an ATX PSU and interfaces to an external 110VAC pure-sine inverter module. The custom PCB should be treated as a low-voltage carrier/distribution board plus a hazardous-voltage terminal area, not as a certified appliance by itself.
Required safety choices
  • Use a certified/prebuilt pure-sine inverter module for the 110VAC 60Hz motor supply.
  • Keep 110VAC conductors isolated from low-voltage ATX/DC sections in layout.
  • Use clear silkscreen warnings near J2: HAZARDOUS 110VAC.
  • Use suitable enclosure, strain relief, insulation, and inaccessible live terminals before operating near people.
  • Fuse the +12V inverter feed appropriately for the selected inverter module.
Layout constraints to apply next
  • Place J2 at a board edge and away from low-voltage connectors.
  • Maintain conservative creepage/clearance between AC nets and SELV/DC nets; use slots or keepouts if needed.
  • Route +24V and +12V high-current paths with wide copper sized for expected current.
  • Keep the 79L05 regulator and its capacitors close together.
Open compliance caveat
This design is not automatically UL/CE/FCC certified. If installed in a product or enclosure, the final assembly needs appropriate electrical safety review and testing.
  • Required safety choices

  • Layout constraints to apply next

  • Open compliance caveat