Circuit Review


The complete 24 VAC, 100 W constant-resistance load schematic is generated and independently reviewed. It contains 67 components, AD633 conductance control, OPA197 current regulation, 50 mΩ shunt, hardware overcurrent/thermal shutdown, test points, and isolated interfaces; ERC and legibility checks are clean.
The defective IRFP250N library part was replaced with the linear-rated IXTH75N10L2, correctly mapped Gate–Drain–Source.
Open bench-validation items
  • Verify current-loop stability and tune compensation.
  • Select a real Kelvin 50 mΩ / 5 W shunt MPN.
  • Validate MOSFET cooling and DC SOA experimentally.
  • Confirm default-off latch behavior during power sequencing.
Project files:
Suggested next steps
  1. Review the schematic and scaling.
  2. Select the physical shunt and heatsink arrangement.
  3. Simulate or bench-test loop compensation.
  4. Proceed to PCB constraints and placement.
there is a lot of errors in airwires
I’ll inspect the current airwire report and layout state, determine whether the issue is missing schematic connectivity or simply an unrouted/unplaced PCB, then fix the appropriate root cause.
The 127 airwires are PCB routing errors, not schematic errors. The schematic connectivity is valid, but all 67 footprints are scattered outside the default 160 × 100 mm board and no copper has been routed yet.
Proposed PCB setup:
  • Board: 100 × 100 mm rectangular
  • Stackup: 4 layers, standard FR-4
  • Copper: preferably 2 oz outer layers for the load-current path
  • Top side: all components
  • Edges: AC input and fuse left; command/power/control connectors opposite edge
  • Power section: bridge, Q1, shunt and heavy terminals grouped near an edge
  • Q1: placed at the board edge for external heatsink mounting
  • Analog section: AD633, OPA197 and sensing network separated from bridge/gate-current paths
  • Routing: wide high-current loop first, Kelvin shunt traces separately, then analog/control signals
  • Thermal note: Q1 dissipates externally through the heatsink; the PCB must not be expected to absorb 100 W
Confirm this 100 × 100 mm, 4-layer, top-side-only arrangement with Q1 at the edge, and I’ll place and route the PCB to eliminate the airwires.

Waiting for input


Schematic is Auto-placed

The schematic has been arranged automatically. Flux can redraw it to be more readable, with components placed in related groups and wires drawn more legibly. This takes about 10-60 mins.

Design Notes
Core Equations and Scaling
  • RLOAD = VRMS²/P = 24²/100 = 5.76 Ω.
  • IRMS = P/VRMS = 4.167 A; IPEAK = IRMS·√2 = 5.893 A.
  • With RSHUNT = 0.050 Ω, peak shunt command is approximately 0.295 V and shunt dissipation is IRMS²·R = 0.868 W.
  • VRECT divider: (46.4k + 46.4k) / 10.0k; at 33.941 V peak, VRECT_SCALED = 3.302 V.
  • Command divider: 24.9k / 9.31k; at 3.3 V input, G_CMD_SCALED = 0.8981 V.
  • AD633 maximum output: 3.3017·0.8981/10 = 0.2965 V, corresponding to 5.93 A peak. The multiplier transfer equation is datasheet-defined.
  • Overcurrent divider from 2.495 V: 66.5k / 10.0k, producing 0.3261 V or 6.52 A with the 50 mΩ shunt.
Current-Loop Starting Values
  • OPA197 supply: ±15 V. It supports ±2.25 V to ±18 V and input common mode extending around both rails.
  • Op-amp output isolation resistor: 1.0 kΩ.
  • Gate resistor: 100 Ω.
  • Gate-source pull-down: 47 kΩ.
  • Gate-source zener: 15 V.
  • Initial compensation: 1 nF from op-amp output to inverting input, with an optional series-compensation footprint/value of 1 kΩ for tuning during bring-up.
  • Begin testing with the command limited to 10–20% and a current-limited AC source.
Protection Logic
  • LM393 comparator A: +IN=filtered VSHUNT, -IN=0.326 V threshold; open-collector output is low normally and released high on overcurrent.
  • Comparator B is biased to a defined state and its unused output is intentionally unconnected.
  • CD4013 SET is diode-ORed from overcurrent and thermostat-open nodes.
  • A capacitor from +15 V to SET plus a SET pull-down creates a power-up fault pulse.
  • RESET has a pull-down and is pulsed high by the external manual reset/enable contact.
  • Q=1 means fault latched and drives the NPN gate-source clamp; Q-bar=1 means enabled.
  • The CD4013 recommended supply range is 3–18 V.
Component Choices
  • AD633JRZ-R7 multiplier, SOIC-8.
  • OPA197IDBVT current-loop amplifier, SOT-23-5.
  • IXTH75N10L2, 100 V TO-247 Linear L2 MOSFET. The datasheet identifies it as designed for linear operation and provides forward-bias SOA data through DC.
  • LM393DR2G comparator, SOIC-8.
  • CD4013BM hardware latch, SOIC-14.
  • TL431AIDBZRG4 local 2.495 V shunt reference.
  • KBPC1510W bridge, rated 15 A and 1000 V.
  • Littelfuse 021506.3MXEP 6.3 A time-delay fuse.
  • TDK B72220S0300K101 30 VAC MOV.
  • Generic 50 mΩ, 5 W, 1% low-inductance current-sense shunt is used because an exact suitable real shunt was not available in the Flux library; replace with an approved Kelvin current-sense MPN before production.
Prototype Limitations and Risks
  • Isolated 24 VAC only. Not mains capable. 100 W absolute prototype limit.
  • IRFP250N was rejected because its available datasheet SOA is single-pulse only, not guaranteed DC SOA.
  • Q1 is now IXTH75N10L2. Verified physical mapping is pin 1=Gate→GATE, pin 2=Drain→VRECT, pin 3=Source→VSHUNT, with the tab connected to Drain.
  • The linear-rated replacement reduces the prior device-selection risk but does not by itself validate 100 W continuous operation; thermal design and operating-point SOA must still be checked.
  • A large characterized heatsink, forced airflow, and normally-closed thermostat are mandatory.
  • Bridge dissipation and connector/fuse heating must be measured at full load.
  • Do not populate any large capacitance across VRECT.
Initial Calibration Approach
  1. Power only the isolated ±15 V supply; verify rails, 2.495 V reference, 0.326 V OC threshold, default fault latch, and gate clamped low.
  2. Close thermostat input and pulse RESET/ENABLE; verify Q-bar indicates enabled and gate remains low with zero command.
  3. Apply a precision 0–3.3 V command and verify the command divider reaches approximately 0.898 V at full scale.
  4. Apply low-voltage isolated AC and verify VRECT_SCALED ratio and IREF multiplication.
  5. Use a current-limited source and increase command slowly while checking VSHUNT ≈ IREF.
  6. Inject approximately 0.33 V into the shunt-sense input and verify the independent latch clamps gate-source low.
  7. Tune compensation only after observing gate and shunt waveforms with a scope; do not exceed low-power operation until stable.
Final Schematic Verification
  • Completed schematic contains 67 components and 28 named nets, with ten test points on VRECT, scaled/reference, command, shunt, gate, fault, and supply nodes.
  • Fresh post-Q1-replacement review on Electrical Rule Checks and Schematic Legibility Checks returned no ERROR, WARNING, OPEN, UNCERTAIN, or USER items at 2026-09-11T06:25:18.285Z.
  • Connectivity inspection confirmed the required bridge-to-MOSFET-to-shunt path, AD633-to-OPA197 current loop, independent LM393/CD4013 fault chain, thermostat interlock, and NPN gate-source clamp.
  • Idealized 50 Hz transient verification with a modeled 1.8 V bridge drop gave 24.00 V RMS input, 5.62 A peak, 3.91 A RMS, 93.84 W input power, and 6.14 Ω effective source-side resistance. VRECT and current return to zero every crossing, confirming no reservoir hold-up.
  • The lower-than-100 W simulated result is due to bridge-drop distortion. Achieving exactly 100 W at the transformer secondary would require revised scaling or bridge-drop compensation and must not be done without repeating SOA and thermal review.
  • Detailed closed-loop stability remains unverified because the transient model used an ideal controlled current sink; compensation values are bring-up starting points only.
  • Focused Q1 correction: replaced IRFP250NPBF with IXTH75N10L2 and explicitly reconnected all three numbered terminals after replacement removed pin-name connectivity.
  • Core Equations and Scaling

  • Current-Loop Starting Values

  • Protection Logic

  • Component Choices

  • Prototype Limitations and Risks

  • Initial Calibration Approach

  • Final Schematic Verification