Board Routing


Finish routing this board.
Thought for 40 sec
Accessed knowledge.
Thought for 16 sec — Evaluating complex execution
Referenced guidance.
Thought for a moment

Routing Repair Handoff
Scope and disposition — 2026-09-21
This is a scoped batch handoff, not routing completion or manufacturing approval.

Table


Assigned itemStatusResult / blocker
Repair U2 EN_UVLO land from manufacturer evidenceCompletedBoard-only pin-7 L-land override persisted and was read back; pin/net identity preserved. This does not mean its route is complete.
Minimal U206/U208 placement adjustmentCompleted (physical edits); failed (escape objective)U206 +0.500 mm X and U208 +0.400 mm X retained; no supporting passive moved. Final DRC reports no component-body overlap or pad-access finding, but the autorouter still rejects their output pins.
Remove only stale copper caused by these movesFailedThe single newly identified redundant VBAT_PROTECTED stub was rejected as protected generated copper. No copper was deleted and no protection bypass attempted.
Complete remaining board routingFailedOne full-board autoroute pass returned unrouteable, with 415 airwires. No repeat pass performed because the tool says additional passes will not fix its blocked pins.
Targeted cleanupUnattemptedCampaign returned targetedRoutingAllowed: false; no targeted-route calls were made.
Preserve schematic, outline, stackup and existing width/clearance intentCompletedNo schematic edits, component replacements, board resizing, stackup changes, or trace-width/clearance reductions.
Read-only verification and handoffCompletedFresh routing-state, DRC, pad-geometry, placement, and logical-net reads obtained.
Retained changes
U2 EN_UVLO footprint
  • Part: LM65645SRZTRQ1, library UID 09539ad5-1a72-4448-b6ea-c7fa986c3197.
  • Manufacturer reference: TI LM65645-Q1 datasheet, SNVSCH2A, page 61, RZT0020A example board layout, drawing 4228518/C.
  • EN/UVLO is pin 7.
  • The datasheet includes the RZT0020A land-pattern drawing.
  • Geometry evidence status: exact coordinates below came from direct inspection and vector extraction of the manufacturer PDF, not a machine-verified coordinate answer from the datasheet-query service. The geometry query did not independently substantiate those coordinates.
  • Corrected only connected pin 7, not the library project or disconnected anonymous mount copper. Original connected copper was approximately Ø0.258747 mm.
  • New rounded L copper: package-coordinate X −1.500 to −0.925 mm, Y −2.000 to −1.375 mm; 0.575 × 0.625 mm overall; 0.25 mm arms; external R0.05 mm; concave R0.10 mm, supported by PDF vectors.
  • Pad anchor: (−1.05, −1.5) mm relative to footprint, Top SMD, 0° rotation; U2 remains at (8,70) mm.
  • Ruleset: U2 EN_UVLO RZT0020A pin 7 land repair, UID 3fd7b16c-8784-483c-a175-d94914312968.
  • Target pad: 09a7aea1-51c2-480c-9057-bb3fe6b915d1__7368fd2f-fb9e-41e3-854e-8e89140e4a72.
  • Read-back confirms active Top custom SVG copper, unchanged VBAT_PROTECTED net (0d432e08-6c2a-47be-943f-a8afa42f0f62), and the correct extents after curve tessellation. The generic computed-size field still shows the old circular size; the custom SVG defines the copper.
  • Limitation: other U2 corner lands and DAP appeared suspicious in inspection and were outside this pin-7-only repair. Do not treat the entire U2 footprint as validated.
Placement

Table


ComponentOriginal X,Y mmFinal X,Y mmRotation
U20697.296, −63.39397.796, −63.393270°, unchanged
U20897.151, −50.50297.551, −50.502180°, unchanged
Final coordinates were confirmed in the live 2D layout after autorouting. All supporting passive positions remain unchanged. U208's initial −0.400 mm Y trial collided with R208_EN_PD and existing copper; a subsequent −0.400 mm X trial intersected a valid VBAT via with SCLK/CSN. Both trials were replaced with the final +0.400 mm X offset, which cleared those introduced findings without deleting the valid via.
Neckdowns and preservation
Two neckdown-generation calls each reported 34 deterministic neckdowns. Existing universal clearance 3.8 mil / minimum 3.5 mil, GND default 0.15 mm, fine battery-pin defaults and explicit wide power trunks, ABS inlet 2.5 mm and outlet 1.5 mm constraints, and U206/U208 0.30 mm local escape intent were not weakened. Board remains the existing 270 × 165 mm rounded outline with custom four-layer stackup, 2 oz outer and 1 oz inner copper.
Routing result
  • Baseline live routing-state: 410 airwires, 18 redundant copper nodes in 11 groups.
  • Post-edits autoroute job: auto-layout-682f3a87-bc97-4877-aca9-559fc1cdb730.
  • Outcome: unrouteable, 415 remaining airwires; campaign attempts 1, reported airwireDelta −1 and bestAirwires 415. Thus the pass improved its immediate starting state by one connection, but the final board has five more airwires than the session baseline following placement/fanout changes. This is not a successful full-route result.
  • No second autoroute pass; no targeted routing.
  • Initial successful preflight identified five inaccessible pads. Subsequent stand-alone checks repeatedly timed out with HTTP 524. Autorouting ultimately supplied a fresh anomaly report identifying six inaccessible pads:

Table


NetBlocked pins
VBAT_PROTECTEDU2 EN_UVLO
ALSD_SOLENOIDBoth U206 OUT0 pads (21/22)
ATTESA_PUMP_RELAYU208 OUT1
ATTESA_FAILSAFE_SOLU208 OUT2
ATTESA_MAIN_SOLOne U205 OUT pad, additionally reported by final run
The router also reported 23 same-net overlapping-pin warnings and five informational via-at-SMD adaptations. Same-net overlap warnings are not automatically foreign-net shorts. The phrase “removed from net” in its report describes the router's treatment of blocked pins: a subsequent logical-net read confirmed both U206 OUT0 pins, U208 OUT1/OUT2, U205 OUT pins, and U2 EN_UVLO still belong to their schematic nets.
Fresh verification
Live routing-state after the route pass: 415 airwires, 34 redundant copper nodes in 15 groups.
Fresh DRC at approximately 19:46 UTC:
  • Error: 415 missing routed connections, independently present in routing-state and Airwires DRC.
  • Error: one pre-existing foreign-net copper overlap remains.
  • Error: two pre-existing component keepout violations remain.
  • Warning: one pre-existing body-overhang/outside-board finding remains.
  • No returned errors/warnings for component-body overlap, pad-access clearance, invalid pads, or stackup validation in the explicitly requested check set. Absence of those findings does not override the autorouter's blocked-pin result.
  • No new persistent copper short from the final U206/U208 placement.
Exact persistent short
Existing via: autoRouted.auto-layout-e6938573-feca-4e0d-bf68-19508f3de1ad.e44ef1ec-b9f1-4549-8a01-8337c9a78852.SmartVia.316f04ddd7c9074c72b0c5f364525481.0df2e1fc-0f98-4ea7-bf46-847637b8abda.0-0
Existing foreign-net trace: autoRouted.auto-layout-e6938573-feca-4e0d-bf68-19508f3de1ad.0aea0050-2ae2-4602-8a1b-572f69c93ce5.Trace.b458e2d4987b4349210eebc42250bc81
Not deleted: it predates this batch and is outside permission to remove only copper made stale by these moves.
autoRouted.auto-layout-e6938573-feca-4e0d-bf68-19508f3de1ad.0d432e08-6c2a-47be-943f-a8afa42f0f62.Trace.849e18ba007c81825061af9574846092
Before/after redundancy checks identify this as the new stale VBAT_PROTECTED stub associated with the retained shifts. Normal deletion returned “protected generated copper”; it remains intact. Do not bypass that protection. A future authorized repair may need to reconnect its dangling end or use supported regeneration.
Other unchanged findings
  • Keepout component UIDs: 0f002102-e7a2-4945-bca4-de3809784a0c (MCU2), aea10609-8ec6-4bb5-a3f7-ed59f50e672a (designator not resolved in this scoped batch).
  • Body-overhang UID: be1c5f80-e4da-4341-9f57-7c97d95dad7a (designator not resolved).
  • U206's 2D representation shows 1.6 mm square pad placeholders; native short checks do not corroborate a pad-short defect. Custom-shape rendering versus actual router geometry needs investigation before any footprint rewrite.
Lead follow-up
Do not repeat bulk routing without resolving the six reported pin-access causes. Review effective router widths/layers and generated fanout geometry at U2, U206, U208, and the newly reported U205 output; obtain specific authorization before expanding footprint repair or disturbing unrelated copper. Retain this partial work and address the pre-existing short and placement findings before manufacturing. The retained small shifts have not achieved the requested escape objective and may be reconsidered after that root-cause review.
Editor-focus attempts failed because the requester frontend session was absent. No manufacturing export or order was attempted.
  • Scope and disposition — 2026-09-21

  • Retained changes

  • U2 EN_UVLO footprint

  • Placement

  • Neckdowns and preservation

  • Routing result

  • Fresh verification

  • Exact persistent short

  • Protected movement-related stub

  • Other unchanged findings

  • Lead follow-up