Power Budget
ABS actuator-path rating revision — 2026-08-23
Authoritative load and path requirements
The shared PCB power path feeding the ABS smart high-side drivers shall be designed and qualified for 30 A continuous. No more than four ABS solenoids are expected to be energized simultaneously, and their combined surge current shall not exceed 30 A under the intended control strategy.
The shared ABS supply path shall additionally survive a 60 A fuse-clearing transient without PCB damage, delamination, via failure, connector damage, shunt damage, MOSFET overstress, or unsafe loss of isolation. The fuse is external to the controller; no additional PCB or enclosure fuse is required. The permitted duration and I²t are controlled by the vehicle-side external fuse time-current curve; 60 A is not a continuous operating rating.

Table


CircuitRequired ratingOperating constraint
Shared ABS supply path30 A continuousMaximum four ABS solenoids simultaneously active
Shared ABS path fuse-survival transient60 ADuration/I²t limited by final production fuse
Each ABS solenoid output10 ABranch copper, driver channel, connector contact and harness must all qualify
ATTESA main/failsafe solenoid outputs10 A eachIndividual branch rating; simultaneous-load budget remains controlled
A-LSD solenoid output10 AIndividual branch rating
ATTESA pump-relay output1 A maximumRelay coil only; expected load approximately 0.2 A; do not upgrade or use for direct pump drive
The 10 A branch ratings are circuit withstand/design ratings, not permission to command unrestricted simultaneous loads. Firmware and hardware authorization must enforce the four-solenoid/30 A aggregate ABS limit.
Shared-path qualification requirements
Production release requires every controller-side series element from the harness entry through the ABS driver supply distribution to meet both the 30 A continuous thermal requirement and the external fuse's 60 A clearing pulse/I²t requirement. This includes the connector contact group and crimps, wire gauge, PCB collector and trunks on every participating layer, layer-transition vias, protection/disconnect MOSFETs, shunt and its terminals, solder joints, driver-supply fanout, and return-path arrangement.
The PCB-mounted MINI fuse holder is not required by the release architecture and must not be treated as a series-path rating constraint. The current J_MAIN six-contact group is 30 A only at the cited 100 °C all-positions-active condition and falls to 18 A at 125 °C, so it has no useful 30 A margin at 100 °C and is noncompliant at 125 °C without a qualified lower ambient, additional current-sharing capacity, or another connector solution. Existing 40-via transitions, shunt, disconnect stage and broad copper are design starting points only and require current-density, temperature-rise, current-sharing and external-fuse-I²t validation.
Acceptance testing shall include 30 A steady-state operation at the maximum qualified enclosure/connector ambient until thermal equilibrium, followed by representative 60 A fuse-clearing pulses using the selected fuse's worst-case time-current tolerance. Record voltage drop and temperature at connector contacts, fuse/holder terminals, copper neckdowns, via fields, shunt terminals, MOSFETs and driver-supply branches.
Main connector revision — 2026-08-14
The final main connector is TE AMP SUPERSEAL 1.0 5-6447223-7, 44-way right-angle upper-lock. The protected input-stage design target remains approximately 20 A, but connector current must be evaluated using TE's 44-position derating data rather than the 15 A single-circuit reference value.
TE 44-position allowable current
Source: TE Product Specification 108-78176-2. Values require at least 0.85 mm² wire.

Table


Ambient temperatureAll positions activeSingle position active
60 °C7 A/contact15 A/contact
80 °C6 A/contact13 A/contact
100 °C5 A/contact11 A/contact
125 °C3 A/contact6 A/contact
The allowable contact-region temperature is 150 °C. The general connector operating range is −40 to +125 °C. The 15 A figure is not a simultaneous 44-contact rating.
Staged main power contacts on J_MAIN

Table


PathContacts60 °C all-active capacity80 °C100 °C125 °C
Permanent +12 V642 A36 A30 A18 A
Power ground642 A36 A30 A18 A
The two wires in each parallel group must use equal conductor area, insulation system, crimp process and practical length. PCB entry copper must use symmetric equal-current geometry. Contact paralleling is not permission to undersize wire, copper, vias, fusing or the protection stage.
Current-allocation conclusion
Six equal parallel contacts per polarity support the revised 30 A target with 40% margin at 60 °C, 20% at 80 °C, and zero tabulated margin at 100 °C using TE's all-positions-active table. At 125 °C the capacity is only 18 A, so the revised 30 A target cannot be supported over the connector's entire rated temperature range even with every available cavity allocated to power/return.
Production release therefore requires a qualified connector-region ambient limit below 100 °C with adequate margin, active current derating/limiting, additional qualified parallel contacts, or TE-supported application-specific simultaneous-loading/thermal qualification. J_MAIN is electrically staged, but exact STEP/CAD is unavailable and the legacy connectors remain installed pending final placement/mechanical validation.
Switched ignition sense load
The switched line is a sense/enable input, not an operating-current feed. Its steady-state current is approximately (VIGN − Vf)/(300 kΩ + 100 kΩ):

Table


Ignition voltageApprox. sense currentApprox. LM74930 EN voltage
9 V20.8 µA2.08 V
12 V28.3 µA2.83 V
16 V38.3 µA3.83 V
+200 V pulse0.50 mA49.8 V
LM74930-Q1 EN rising threshold is 0.8–1.05 V and falling threshold is 0.41–0.7 V. The calculated worst-case ignition turn-on threshold is approximately 4.9 V including 0.7 V diode drop. The 300 kΩ source / 100 kΩ pull-down and 470 nF capacitor give about 35 ms input deglitch and about 47 ms default-off discharge.
Key states

Table


StateExpected permanent-battery load
Ignition absentLM74930-Q1 shutdown: 2.5 µA typical, 5 µA maximum, plus unavoidable leakage of input TVS, capacitors and fuse/protection parts
Ignition present, bootingProtected rail powers regulators, three controller boards, supervision, sensing and smart switches; actuator current remains load-dependent
Fault/watchdog/brownoutAuthorization logic forces actuator commands off; ignition control does not bypass watchdog/brownout gating
Open power-budget work
A complete worst-case rail-by-rail and actuator-duty load table remains required before production release, including all three ESP32 DevKits, 5 V and 3V3 loads, sensor/reference outputs, smart-switch quiescent current, measured solenoid peak/hold waveforms and duty cycles, pump-relay current, enclosure ambient, connector simultaneous-loading factor, 30 A steady-state PCB current-density/thermal verification, and 60 A fuse-clearing pulse/I²t verification.
  • ABS actuator-path rating revision — 2026-08-23

  • Authoritative load and path requirements

  • Shared-path qualification requirements

  • Main connector revision — 2026-08-14

  • TE 44-position allowable current

  • Staged main power contacts on J_MAIN

  • Current-allocation conclusion

  • Switched ignition sense load

  • Key states

  • Open power-budget work