Board Routing


Finish routing this board.
Thought for 40 sec
Accessed knowledge.
Thought for 16 sec — Evaluating complex execution
Referenced guidance.
Thought for a moment

Input Force-Chain Routing Verification
Scope status
  • Completed: routed the live input-protection force chain J_MAIN:14–16/28–30 → Q_HGATE → Q_DGATE → R_SENSE without moving components.
  • Partially completed: routed VBAT_PROTECTED from R_SENSE:P2 to the valid supply pads of U201, U203, U206, and U209.
  • Blocked: U205, U207, and U208 protected-supply feeds. Their source footprints place every pad at the same coordinate, so routing a supply pad would short unrelated terminals.
  • Not qualified for release: the present VBAT_PROTECTED trunk is connectivity copper, not an aggregate actuator-current solution.
Routed force path
VBAT_RAW
Five parallel Top-layer routes were added from the six-contact J_MAIN input manifold into separate Q_HGATE drain pads:
  • 69.81 mm × 3.0 mm
  • 62.61 mm × 3.0 mm
  • 70.77 mm × 3.0 mm
  • 74.97 mm × 2.5 mm
  • 66.82 mm × 2.5 mm
The attempted direct J_MAIN:28 → Q_HGATE:DRAIN_4 path was blocked by existing obstacles at both 3.0 mm and 2.0 mm. DRAIN_4 remains connected through the shared connector/drain copper network; focused DRAIN airwire review shows no Q_HGATE or Q_DGATE drain-pad airwire.
FET_COMMON_SOURCE
Seven parallel Q_HGATE-to-Q_DGATE source routes were added:
  • four paths at 1.5 mm width, lengths 35.00, 20.86, 26.46, and 24.96 mm
  • three paths at 1.2 mm width, lengths 31.42, 28.41, and 22.62 mm
A short local Q_DGATE SOURCE_2-to-SOURCE_1 link and the D_GCLAMP_H anode branch were also routed. A SOURCE_8 attempt that introduced foreign-net overlap was deleted.
VBAT_IDEAL_DIODE_OUT
Parallel Q_DGATE-drain-to-R_SENSE:P1 routes were added at 1.5–3.0 mm widths. Two paths use two vias each. One redundant route that was reported overlapping foreign copper was deleted; focused DRAIN airwire review still shows no Q_DGATE drain-pad airwire afterward.
VBAT_PROTECTED
The routed daisy-chain is:
  • R_SENSE:P2 → U201:VS: 126.03 mm × 2.0 mm
  • U201:VS → U203:VS: 17.25 mm × 1.5 mm
  • U203:VS → U206:EP: 34.86 mm × 1.5 mm
  • U206:EP → U209:EP: 61.86 mm × 1.5 mm
U201/U203 use their VS pads; U206/U209 use the exposed supply pad identified by the live netlist.
Copper resistance estimate
Assumptions: 1 oz copper = 35 µm, copper resistivity 1.724×10⁻⁸ Ω·m, DC only, and no allowance for vias, connector contacts, pad spreading, MOSFET RDS(on), shunt terminals, or temperature rise.

Table


SectionEstimated copper resistanceLoss at 20 ALoss at 30 A
VBAT_RAW, five parallel routes2.414 mΩ0.966 W2.173 W
FET_COMMON_SOURCE, seven parallel routes1.349 mΩ0.540 W1.214 W
VBAT_IDEAL_DIODE_OUT, conservative four-route caseup to 1.947 mΩ0.779 W1.752 W
These estimates assume useful current sharing and omit via resistance. The two via-transitioned ideal-diode paths require proper via arrays before high-current qualification.
The protected-feed trunk is unacceptable for aggregate actuator current. Its first 126.03 mm × 2.0 mm segment is approximately 31.04 mΩ and carries the total downstream current: about 3.10 W at 10 A, 12.42 W at 20 A, and 27.94 W at 30 A. It must be replaced by broad pours/straps, parallel layers, and transition via arrays.
Footprint blockers
U205 — BTS7004-1EPZ
All OUT, VS, GND, IN, DEN, IS, NC, and exposed-pad geometry is coincident at (67, 24). The exact VS terminal UID is c838fe23-67d5-44c5-858d-c6b13eddddf6. Infineon identifies this device as PG-TSDSO-14; U201 provides a usable same-package geometry reference, but the source part must be repaired or replaced before routing.
U207/U208 — TLE94108ES
All 24 signal/supply pads and the exposed pad are coincident at (67, -12) for U207 and (67, -29) for U208. VS terminal UIDs are 513f1427-8519-4998-ae8d-67db25f814dd and 46642146-e2fc-4d74-876d-3b74f41fb968. Infineon identifies the package as PG-TSDSO-24 with 0.65 mm lead pitch; exact manufacturer land-pattern geometry was not available in the product datasheet evidence used for this pass.
Part-quality reports were filed for both affected library parts.
Verification evidence
  • Focused DRAIN airwire checks contain no Q_HGATE (802bbc28-3ad6-4d32-b0ef-a94d6803be87) or Q_DGATE (fcd81146-4d93-4342-98e4-82da5e2356d6) drain-pad entries.
  • Focused SOURCE checks contain no remaining Q_HGATE/Q_DGATE source-bank airwire after the local source link and clamp branch.
  • Confirmed route-induced foreign-net overlap findings were removed (Trace 1df4 and Trace 55f6).
  • The board remains globally unrouted, so unrelated pre-existing airwires and DRC findings remain outside this batch.
Remaining release actions
  1. Repair or replace U205/U207/U208 footprints, then route their VBAT_PROTECTED pads.
  2. Replace the narrow protected-feed daisy-chain with release-ready high-current pours/straps and via arrays.
  3. Review the two via-transitioned VBAT_IDEAL_DIODE_OUT paths for current sharing and add transition arrays.
  4. Qualify the PCB path against the external vehicle fuse maximum clearing time and I²t; those fuse data were not available in this routing pass.
2026-09-09 reinforcement continuation
Batch status
  • Completed — VBAT_RAW: added 7 mm copper spines on Mid-Layer 2 and Bottom from the connector-side manifold toward Q_HGATE, plus a 25-via Top/Mid-Layer-2/Bottom transition array at the drain bank. The existing balanced Top-layer J_MAIN manifold was retained.
  • Completed — FET_COMMON_SOURCE: added seven 1.1 mm local pad neckdowns per MOSFET into 2.5 mm Top landing buses, a 6 mm Mid-Layer 2/Bottom shared bus, and two 12-via transition arrays.
  • Completed — VBAT_IDEAL_DIODE_OUT: added 4.5 mm Mid-Layer 2 and Bottom spines and 24 distributed transition vias tied into the existing 1.5–3 mm Top routing. Kelvin/sense routing was left intact.
  • Failed/rolled back — VBAT_PROTECTED: two broad-corridor attempts were made. The first 4.5/8/8 mm shared spine plus distribution branches introduced 34 foreign-net copper-overlap findings and 6 airwire changes. A reduced shared-spine-only retry introduced 21 copper-overlap findings and 2 airwire changes. Both mutations were atomically reverted; no unsafe added protected copper remains.
  • Unattempted after stop condition: rebuilding U201/U203/U206/U209 as 8 A branches, because a safe broad post-shunt distribution corridor could not be established first.
  • Intentionally unrouted: U205/U207/U208 remain blocked by collapsed/coincident footprint pads.
First-order copper-only estimate after reinforcement
Assumptions: 1 oz copper, 35 µm thickness, 20 °C copper resistivity, ideal parallel current sharing, and no allowance for via barrels, pad spreading, connector resistance, MOSFET RDS(on), temperature rise, or manufacturing tolerance.

Table


Reinforced sectionApprox. effective copper resistanceDrop at 30 ACopper loss at 30 A
VBAT_RAW0.52 mΩ15.5 mV0.46 W
FET_COMMON_SOURCE0.63 mΩ19.0 mV0.57 W
VBAT_IDEAL_DIODE_OUT0.75 mΩ22.5 mV0.68 W
Three reinforced PCB sections combined1.90 mΩ57 mV1.71 W
The 0.75 mΩ shunt itself dissipates 0.675 W at the 30 A external-fuse rating and drops 22.5 mV. Including the shunt, but excluding MOSFETs, vias, pads, contacts, and the still-narrow post-shunt trunk, the first-order force-chain estimate is about 79.5 mV and 2.39 W at 30 A.
These figures are not release qualification. Via-current sharing, copper temperature coefficient, enclosure thermal conditions, and the external fuse's maximum clearing time and I²t still require validation.
Post-mutation verification
  • Focused DRC review returned no open airwire, overlapping-copper, dangling-trace, or under-connected-via checks matching VBAT_RAW, FET_COMMON_SOURCE, VBAT_IDEAL_DIODE_OUT, VBAT_PROTECTED, or Q_HGATE after the unsafe protected-path attempts were reverted.
  • Each successful reinforcement mutation reported no new foreign-net copper-overlap errors; only redundant-route notices and balanced airwire bookkeeping were reported.
  • Mid-Layer 1 remains the GND plane and was not used for added power copper.
  • Global layout status remains 791 airwires. The board is not globally routed, and the existing collapsed U205/U207/U208 footprints account for extensive unrelated overlap errors.
Required next step
The remaining release blocker is the post-shunt VBAT_PROTECTED corridor from R_SENSE:P2 to the distribution region. The present geometry cannot accept a genuinely broad three-layer corridor without shorting existing copper. Resolve this by creating a dedicated corridor through component/route relocation or by revising the board placement, then rebuild the protected trunk and 8 A branches. Do not qualify the current 1.5–2 mm daisy-chain for aggregate actuator current.
2026-09-09 — 40 A convergence decision
Final status
  • Failed — safe continuous 40 A corridor: the attempted multilayer corridor was not defensible for continuous 40 A on the present 1 oz stackup.
  • Completed — rollback: all corridor traces and added transition vias from the final attempt were reverted to commit #f89380e4. The user's concurrent MCU state was restored afterward: MCU1 at (14.7751, -47), MCU2 at (-30, -47), both at 180°.
  • Verified: routing state returned to the pre-attempt baseline of 791 airwires. The original 1.5–2 mm VBAT_PROTECTED daisy-chain is restored and remains explicitly not current-qualified.
Exact geometric blocker
  • The board upper edge is y = 80.5 mm.
  • The practical horizontal corridor runs from the shunt/distribution entry near x = 105 mm to the vertical distribution spine near x = 38 mm.
  • A 9 mm Mid-Layer-2 trunk centered at y = 78 mm occupies y = 73.5…82.5 mm: it extends 2.0 mm beyond the board.
  • Existing unlike-net VBAT_RAW and FET_COMMON_SOURCE via rows occupy x ≈ 62.5…95 mm, y = 73.0…73.4 mm, directly beneath that trunk. Their 0.6 mm pads also collide with the trunk's lower edge once copper clearance is included.
  • Reducing the inner trunk to 5 mm clears the via field and board edge, but leaves only 14 mm aggregate copper width across Top/Mid-Layer-2/Bottom (4.5/5/4.5 mm). This is not a conservative continuous-40-A solution on 1 oz copper.
Minimum robust physical change set
  1. Create the corridor: with the existing board outline fixed, center the 9 mm inner trunk at y = 76 mm so its upper edge lands at y = 80.5 mm, and relocate the obstructing via rows from y = 73.0…73.4 mm to y ≤ 70.95 mm. The worst row therefore needs at least 2.45 mm downward displacement, with its associated VBAT_RAW/FET_COMMON_SOURCE copper moved consistently.
  2. Increase copper capacity: use at least 2 oz copper for the power layers, or provide additional parallel copper area validated to the selected temperature-rise limit. The attempted 1 oz corridor cannot be signed off at continuous 40 A.
  3. Replace the shunt footprint/part: the present R_SENSE is 0.75 mΩ, 1 W, 2512. It dissipates 1.2 W at 40 A before derating and its narrow terminal is the unavoidable entry neckdown. Replace it with an automotive ≥2 W wide-terminal shunt package and provide immediate multilayer copper/via spreading at both terminals.
  4. Repair driver footprints: U205, U207, and U208 still have collapsed coincident pads; their footprints must be repaired/replaced before the protected branches can be completed.
The release design must then be re-routed and qualified against the external vehicle fuse maximum clearing time and I²t; the PCB path should retain margin so the external fuse remains the limiting element.
  • Scope status

  • Routed force path

  • `VBAT_RAW`

  • `FET_COMMON_SOURCE`

  • `VBAT_IDEAL_DIODE_OUT`

  • `VBAT_PROTECTED`

  • Copper resistance estimate

  • Footprint blockers

  • U205 — BTS7004-1EPZ

  • U207/U208 — TLE94108ES

  • Verification evidence

  • Remaining release actions

  • 2026-09-09 reinforcement continuation

  • Batch status

  • First-order copper-only estimate after reinforcement

  • Post-mutation verification

  • Required next step

  • 2026-09-09 — 40 A convergence decision

  • Final status

  • Exact geometric blocker

  • Minimum robust physical change set