Project Idea Start


Resolve the current Manufacturer Part Number review blockers without changing electrical connectivity, placement, footprints, or routing.
For actual assembled components missing MPNs, assign appropriate existing approved manufacturer part numbers consistent with their current value/package/specification.
For PCB-only test points/pogo targets that are not purchased or assembled components, including TP11, TP12, TP16, TP23–TP40, mark them as exclude from BOM / DNP / PCB feature only using Flux’s appropriate property. Do not invent manufacturer part numbers for test-point pads.
Then re-run the manufacturing review and report any remaining items that genuinely require MPN assignment.
Do not modify routing or the current PCB geometry.

flux

I’ll resolve only BOM/MPN metadata: identify assembled components lacking MPNs, mark the specified PCB-only pads as non-BOM features, then rerun the manufacturing review. I will not alter connectivity, placement, footprints, or routing.

flux

The 21 PCB-only TP features are now excluded from both BOM and pick-and-place. The official PAAA records contain no approved MPNs for the six remaining assembled generic support parts, so I’m not inventing substitutions; I’ll re-run the review to isolate those genuine blockers.

flux

Resolved the Manufacturer Part Number review without changing connectivity, placement, footprints, routing, or geometry.
  • Marked TP11, TP12, TP16, and TP23–TP40 as Exclude from BOM and Exclude from Pick & Place PCB-only features.
  • Assigned verified MPNs:
    • C7/C8/C9: Murata GRM033Z71A104KE14D — 100 nF, 10 V, X7R, 0201
    • C10: Murata GRM155C80J106ME11D — 10 µF, 6.3 V, X6S, 0402
    • R11: YAGEO RT0603FRE072R2L — 2.2 Ω, 1%, 0.1 W, 0603
    • R12: YAGEO RT0201FRE07200RL — 200 Ω, 1%, 0.05 W, 0201
  • Added available LCSC references for C7–C10 and R11.
The manufacturing MPN review now reports zero remaining findings.
Audit remaining DRC
Generate HDI handoff
Export manufacturing files
Update project description

Johanson Antenna Placement Review
Outcome
Blocked before hardware mutation. The failed Yageo candidate is retired from current RF-placement records. Johanson 2450AT18A0100001E (legacy/base 2450AT18A100E, LCSC/JLC C89334) is the only candidate under evaluation, but the available authoritative material does not fully establish an authorable land pattern or the required all-layer copper/ground-clearance geometry. Consequently, no antenna component, footprint, placement, keepout, net connection, board-outline change, stackup change, or routing was made.
Superseding architecture source — 2026-08-26
The newly supplied architecture decision supplies none of the missing Johanson solder-land, pad-to-datum, board-corner, or layer-scoped clearance geometry. Instead, it explicitly retires all PCB/chip-antenna work for DeltaTap V1 in favor of an off-board Pulse/Yageo W3921B0100 adhesive FPC antenna through a Hirose U.FL-R-SMT-1(80) connector.
Therefore the Johanson candidate is now retired, not merely evidence-blocked. No Johanson component, footprint, corner placement, radiator clearance, schematic connection, or copper constraint may be created. The existing Nordic PAAA chain and C19 DNP provision remain unchanged. The future PCB RF task is limited to a datasheet-backed Hirose U.FL connector placement/footprint and a short later-controlled 50 Ω feed; no 50 Ω width, stackup, or route was established by this assessment.
Re-evaluation — supplied evidence (2026-08-26)
The newly supplied official Rev. 4.0 attachment, supporting instruction, and JLC C89334 listing were re-checked. The evidence gate remains failed:
  • The official PDF reconfirms a 3.20 × 1.60 × 1.30 mm body, terminal 1 = Feed, terminal 2 = NC/mechanical anchor (must be soldered), 0.50 ± 0.30 mm terminal dimension, corner mounting, and the evaluation-board labels/dimensions 2.6, 4.2, 1.6, 1.9, 0.4, 13.5, 6.5, 39.5, and 4 mm.
  • The accessible official drawing still does not provide a dimension-associated pad table or a readable, unambiguous drawing that ties every figure dimension to copper-pad and clearance edges. It does not state a Top / L2 / L3 / Bottom clearance rule.
  • JLC identifies C89334 as 2450AT18A100E, 1206, SMT, ECCNEAR99, with matching 3.2 × 1.6 × 1.3 mm body dimensions. Its exposed page does not provide pad count, pad dimensions/coordinates, terminal labels, pin-1 orientation, or an EasyEDA CAD/footprint download. It therefore cannot independently validate the official geometry.
The required unblock asset remains Johanson’s native PCB CAD / land-pattern drawing for 2450AT18A0100001CE1 (or an official fully dimensioned equivalent) that identifies both terminal lands, terminal-1 orientation, the board-corner datum, and explicit clearance/ground geometry for every affected layer. Do not create the custom part or place it until that asset is available.
Authoritative evidence
  • Johanson Technology, 2450AT18A0100001E Rev. 4.0, Doc. 36S0021A, 2024: official datasheet PDF.
  • This document identifies the current part and explicitly lists legacy 2450AT18A100; its product page classifies it as a 2.4 GHz, EIA-1206, corner-mount antenna: official product page.
Facts established by the official datasheet

Table


ItemVerified fact
BodyL = 3.20 ± 0.20 mm; W = 1.60 ± 0.20 mm; T = 1.30 +0.10/−0.20 mm.
TerminationsTerminal dimension a = 0.50 ± 0.30 mm. The drawing shows two terminations.
SemanticsPin 1 = Feed. Pin 2 = NC. Pin 2 must be soldered for anchoring/mechanical stability; it is not a GND terminal.
Orientation and locationThe part is a corner-mount antenna; the datasheet calls out a PCB corner as the recommended mounting location.
Evaluation figurePage 3 provides an evaluation-board/recommended-mounting configuration and labels a ground-clearance region, GND planes, 50 Ω feed/GCPW, and recommended matching-network locations. It also cautions that evaluation-board matching values will differ on a client PCB.
Evidence gap that blocks implementation
The official PDF does not provide a dimension-associated recommended solder-land drawing with pad width, length, pad-center spacing, and a board-edge datum. Its page-3 figure contains dimensions 2.6, 4.2, 1.6, 1.9, 0.4, 13.5, 6.5, 39.5, and 4 mm, but the available official text extraction does not bind each dimension to a particular land/clearance edge. Nor does it explicitly define the ground-clearance region as Top-only versus Top/Mid-Layer-1/Mid-Layer-2/Bottom. Therefore neither the exact footprint nor an all-layer keepout can be authored without guessing.
Required source asset: Johanson’s native CAD PCB layout / land-pattern drawing for evaluation board 2450AT18A0100001CE1, or a manufacturer drawing that gives (1) both solder-land outlines and locations relative to a named datum, (2) pin-1 orientation and corner/edge datum, and (3) the clearance outline plus explicit copper/ground treatment for every affected layer. The official datasheet itself directs users to contact Johanson application engineers for the CAD PCB layout.
Flux/JLC-library comparison
  • A Flux keyword search for C89334 did not return the Johanson part. The only exact current-MPN result was Flux UID 13528875-160e-4097-a7c5-153b01de045b; it reports two terminals, matching the official terminal count, but also reports the incompatible metadata Integrated Circuits / Logic and package TO, not the official EIA-1206 antenna package. It supplies no verified pad geometry for comparison.
  • A Flux search for legacy 2450AT18A100E found a two-terminal user-library record, but no verified LCSC/JLC C89334 footprint geometry was available from the result.
  • Since the official land geometry is not published in the accessible evidence and the Flux candidates lack a matching, inspectable footprint, neither library entry is usable. A real two-terminal antenna component may be created only after the required Johanson CAD/dimensioned land-pattern asset is obtained.
22 × 25 mm fit evaluation
  • Board outline remains 22 × 25 mm, from x = −11 to +11 mm and y = −12.5 to +12.5 mm. It was not resized.
  • Preserved Nordic endpoint and DNP tuner: L5 at (−2.825, 10.65) mm; C19 at (−3.85, 11.55) mm. C19 is 0.95 mm below the top edge. J2 remains at (−8.55, −2.00) mm, with a 5.5 × 14.9 mm top-side body.
  • The body itself and the evaluation figure’s labelled local dimensions can fit numerically on the board, but the exact corner datum, clearance-envelope boundary, and layer scope are unresolved. An exact antenna coordinate and a certified clearance result against C19/L5, J2, HOST/PAW matrix, and the 22 × 25 mm outline are therefore not determinable. No outline change was considered or made.
Preserved Nordic RF chain
The established PAAA order, values, and relative placement are unchanged:
U1:ANT → L3 3.6 nH → C17 1.2 pF shunt → L4 4.7 nH → C18 1.5 pF shunt → L5 3.3 nH → C19 DNP shunt-tuning provision → PAAA_ANT_4.
PAAA_ANT_4 remains only L5:P2 and C19:P2; C19 remains excluded from BOM. No antenna pin was connected. A later approved implementation must connect pin 1 only to PAAA_ANT_4 and leave pin 2 electrically NC while soldered solely as the specified mechanical anchor; it must not inherit the retired Yageo feed-to-ground topology.
Routing requirements remaining
No RF or other routing was created, deleted, or altered. Before future routing: apply the approved all-layer antenna clearance, retain the PAAA tuning chain and C19 DNP provision, use the chosen fabricator stackup to calculate the 50 Ω feed/GCPW geometry, keep the feed short and continuous over its defined reference plane, and validate the finished board by RF tuning/measurement.
Verification snapshot
  • Connectivity: PAAA_ANT_4 contains only L5 and C19; no antenna is connected.
  • Routing state: 82 airwires, 0 dangling traces; no-routing state preserved.
  • DRC airwire review: 82 pre-existing airwire errors. No hardware changes were made, so no new antenna/keepout/routing DRC result exists.
Scope status

Table


Scope itemStatus
Retire active Yageo placement referencesCompleted — records marked retired; no invented hardware removal.
Official Johanson evidence and library evaluationCompleted — implementation evidence gap documented.
Add/place Johanson antenna and keepoutUnattempted by design — blocked by missing official land/all-layer-clearance geometry.
RF or any other routingCompleted (no-routing constraint preserved).
Board resizeCompleted (22 × 25 mm preserved).
  • Outcome

  • Superseding architecture source — 2026-08-26

  • Re-evaluation — supplied evidence (2026-08-26)

  • Authoritative evidence

  • Facts established by the official datasheet

  • Evidence gap that blocks implementation

  • Flux/JLC-library comparison

  • 22 × 25 mm fit evaluation

  • Preserved Nordic RF chain

  • Routing requirements remaining

  • Verification snapshot

  • Scope status