HAT Requirements and Open Items
User requirements
- HAT connects to the stated NUCLEO-G747RE board using CN7 and CN10 from the bottom.
- External 5 V input through a four-position Phoenix connector: 1 VCC, 2 GND, 3 NC (not connected), 4 PE.
- External 5 V powers the NUCLEO board, relay control circuitry, CAN transceiver, and RS485 transceiver.
- NUCLEO 3.3 V output supplies an 8 MB flash memory and SD card.
- Two RJ45 connectors for CAN and RS485; assignment and pinouts not yet specified.
- Two-row, three-position-per-row Phoenix connector with six terminals: 1 NC (relay normally closed), 2 COM, 3 NO, 4 GND, 5 IN1, 6 IN2. Physical numbering orientation requires confirmation.
Unverified details and required decisions
- Confirm the exact NUCLEO board model. The user supplied NUCLEO-G747RE; no board documentation, model identity, CN7/CN10 pinout, mating geometry, or power configuration has been verified.
- Confirm what “from bottom” means mechanically, connector gender, stacking orientation, and required board envelope/clearances.
- Verify the approved external 5 V injection point and jumper configuration on the NUCLEO, including USB/debugger backfeed prevention.
- Verify available NUCLEO 3.3 V current against flash and SD-card peak consumption before relying on that rail.
- Define relay contact voltage/current and load type; determine relay coil voltage and driver/protection needs. No mains rating or suitability is assumed.
- Define IN1/IN2 function, signal voltage range, source type, and protection/isolation requirements.
- Define CAN and RS485 connector pinouts, bus speeds, termination/bias configuration, cable grounding/shielding, and isolation requirements. RJ45 ports are not assumed to be Ethernet.
- Define PE bonding strategy; PE is not automatically tied to signal GND.
- Choose flash interface (e.g. SPI/QSPI), SD interface (SPI/SDMMC), and MCU peripheral/pin assignments after checking the exact board.
- Select exact Phoenix connector parts, pitch, numbering, and sourced footprints.
Session state
Only this requirements record has been created. No components, nets, schematic, PCB geometry, placement, routing, or simulations have been created or verified. Execution stopped because the account ran out of ACUs. Resume by confirming the exact board and safety-critical interface requirements, then source board/connector documentation before building the schematic and mechanical interface.