ESP32 S3 Sensor PCB


I’ll fix the remaining capacitor placement and fine-pitch routing constraints, then reroute the affected connections and check the result. I’ll keep the five fixed components and board geometry unchanged, and preserve useful existing traces.
Thought for 1 min 58 sec
Thought for 13 sec
1/3 Fix capacitor placement and fine-pitch/USB routing blockers; apply routing repairs.

Fix capacitor placement and fine-pitch/USB routing blockers; apply routing repairs.

Independently check connectivity, placement and DRC after repairs.

Resolve microphone identity and C14 decoupling with verified physical facts (blocked pending microphone identification).

Thought for 21 sec
Thought for 7 sec
Awaiting 1 task
"PCB Cleanup and Routing Verification" completed.
Created a project doc

Layout Repair Resume Notes

View Document

Layout Repair Resume Notes
User approved fixing remaining PCB layout/routing blockers. This session sent a focused repair continuation to existing executor 6z. Lifecycle wait returned interrupted; a subsequent completion notification arrived, but its report has NOT been retrieved or verified because ACUs ran out. Do not assume no changes, or that repairs succeeded: retrieve persisted executor report and inspect live checks first.
Last verified state before this continuation
40 airwires, zero redundant traces and zero copper shorts; three placement errors (C6 power-stage feed and two C7 neckdown findings), eight advisory warnings. Full findings are in pcb-cleanup-and-routing-verification. Board was not fabrication ready. USB breakout was blocked by foreign copper; prior autoro...
I started the focused placement and routing repairs, but couldn’t retrieve or verify the results before execution stopped. The last verified state was 40 unrouted connections and three placement errors, so the PCB must still be treated as incomplete; I saved the continuation details in Layout Repair Resume Notes.
Execution stopped because your ACUs ran out.

Waiting for input


Board Bring-Up Plan
  1. Unpowered inspection: verify JST polarity (pin 1 BAT+, pin 2 GND), USB-C orientation, charger/regulator exposed pads, and no shorts on USB_5V_PROTECTED, BAT_PLUS, SYS, or 3V3.
  2. USB current-limited power, no battery: apply 5 V with a 100 mA bench limit first. Confirm protected VBUS, charger OUT/SYS, then 3.3 V. Increase current limit only after rails are correct.
  3. Regulator: sweep SYS from 3.0 to 4.4 V on a bench supply and verify 3.3 V under idle load and pulsed load approaching 600 mA. Check switching waveform and temperature.
  4. Battery: connect a known protected 1S cell with correct polarity. Verify battery operation with USB removed.
  5. Charging/power-path: apply USB with total input limited to 500 mA. Confirm system remains operating and charge current folds back as system load rises. Verify nominal charge setting near 500 mA only when system demand permits.
  6. Controls/USB: verify RESET pulls EN low; BOOT+RESET enters download mode; enumerate native USB.
  7. Sensors: read IIS3DWB identity over SPI; verify CS idles high. Capture INMP441 left-channel I2S data and confirm its noise floor responds to acoustic input.
  8. Battery ADC: compare firmware reading with a DMM at 4.2 V, nominal, and low-cell voltages; store calibration.
  9. Pass criteria: no rail exceeds ratings, 3V3 remains in regulation, USB current stays within configured limit, system does not reset during charge/load transitions, and both sensors stream valid data.