You’re right. I checked history: the bad work is exactly 8 routing commits from my last pass, and they can be cleanly reverted without touching your earlier manual move or the C1/property fixes.
Safe recovery point:
Revert to commit #bd42c4c0
This removes only the 8 bad mutate_layout_route edits.
It preserves your prior layout changes and the C1 footprint/property work.
I will not do anything else unless you approve. If you want me to undo the damage, say:
Current Flux footprint read-back versus uploaded KiCad reference — resolved
Current Flux J1 read-back shows the same nominal pin counts and core X spacings, but the local Y coordinates are sign-inverted relative to the uploaded KiCad footprint:
Uploaded main stagger row uses y = 0 and y = -2.54; current Flux local read-back shows the corresponding stagger using y = 0 and y = +2.54.
Uploaded shield tabs use y = +3.30; current Flux local read-back shows shield tabs at y = -3.30.
Uploaded NPTH locating holes use y = +6.35; current Flux local read-back shows locating holes at y = -6.35.
Uploaded LED holes use y = +8.89/+10.92; current Flux local read-back shows LED holes at about y = -8.90/-10.93.
Conclusion: this is most likely a coordinate-convention/read-back artifact, not a real footprint mirror error. The evidence is that every feature is transformed consistently by Y sign only while the X spacing, pad count, pin order, shield-tab spacing, locating-hole spacing, and LED-hole pattern remain coherent. Do not mirror or replace J1 based only on this local-coordinate read-back.
Release recommendation: keep J1 unchanged for now. Before final fab release, verify the actual Gerber + Excellon drill output in an independent viewer or overlay against the uploaded KiCad footprint/Abracon drawing. If the drill map matches the uploaded footprint and connector body orientation relative to the board edge is correct, this item can be signed off. If not, hold fab and correct the footprint asset. Do not move J1 without user approval.
Source / variant evidence
User provided a datasheet screenshot on 2026-07-04 showing Abracon mechanical specifications for the tab-down RJ45 with EMI fingers variant of ARJM11D7-114-AB-EW2.
The screenshot includes two assembly variants:
Tab Down, with EMI Fingers — Wave solder
Tab Down, with EMI Fingers — Reflow
The current project component is a through-hole RJ45/MagJack and should be checked against the wave-solder / through-hole mechanical pattern unless the exact purchased distributor item is confirmed to be the reflow variant.
Key mechanical dimensions visible in provided drawing
For the wave-solder tab-down EMI-finger view:
Table
Feature
Dimension from drawing
Front/body width
15.90 mm
Body depth
21.20 mm
Front height
13.50 mm
Side/rear body height note
3.40 mm at bottom reference area
Contact pitch
2.54 mm
Rear/contact span reference
8.89 mm
Tolerance note
±0.25 mm unless otherwise specified
For the reflow tab-down EMI-finger view, visible values include approximately 15.93 mm width, 21.25 mm depth, 13.30 mm front height, and 3.70 ±0.30 mm bottom standoff/height reference. Do not use these values for the through-hole footprint unless the purchased part is confirmed as reflow style.
Current Flux layout read-back
Current J1 layout component bounds from Flux:
Table
Designator
Center X
Center Y
Layout bounds
J1
-109.00 mm
61.11 mm
23.30 mm × 20.37 mm
These bounds are larger than the body-only dimensions because the footprint includes through-hole pads/mechanical features/EMI tabs. This is not by itself an error, but it means body size alone is insufficient to verify the land pattern.
Release-gate checks still required
Before fab/assembly release:
Confirm the ordered Digi-Key part 535-14151-ND maps to ARJM11D7-114-AB-EW2, tab-down, EMI-finger, through-hole/wave-solder geometry.
Compare the footprint hole/pad coordinates against the Abracon mechanical drawing, not just the component bounding box.
During final manufacturing-output review, confirm the Gerber/drill output matches the uploaded KiCad footprint; the apparent local-Y mirror is considered a read-back convention artifact unless the exported drill map proves otherwise.
Verify:
Shield/EMI tab hole positions and drill sizes.
Signal pin row pitch and offsets.
Center-tap/PoE pin positions.
Pin numbering/orientation relative to board edge and Ethernet cable insertion direction.
Body overhang, keepout, height, and enclosure/edge clearance.
Keep J1 locked in placement unless the user explicitly approves movement.
If a replacement RJ45 is ever considered, qualify it as a mechanical/electrical drop-in: same footprint, same PoE center-tap arrangement, same magnetics topology, same isolation rating, and compatible height/body geometry.
User uploaded Ag59800_Detailed.step on 2026-07-04. It was added to project assets as Ag59800_Detailed.step and associated with PS1 for 3D/mechanical verification.
Automated STEP bounding-box extraction was attempted, but the current file-read/code path could not parse the uploaded STEP directly. The footprint was therefore verified against the Silvertel Ag59800-LPB datasheet mechanical/land-pattern dimensions, with the uploaded STEP retained as the visual 3D overlay reference for final mechanical review.
Datasheet mechanical reference
Silvertel Ag59800-LPB datasheet V2.0, updated June 2026, lists:
Table
Feature
Datasheet value
Nominal module size
50.60 mm × 30.00 mm × 14.70 mm
Maximum module size
51.60 mm × 31.00 mm × 15.60 mm
Feature summary
Ag59800-LPB compact SMT package size approximately 51 mm × 30 mm × 15 mm
Datasheet land-pattern dimensions visible from Figure 17:
Table
Land-pattern feature
Datasheet value
Current PS1 footprint read-back
Result
Pad length
5.00 mm
5.00 mm
Match
Pad width
1.83 mm
1.83 mm
Match
Pad pitch within pad groups
2.46 mm
2.46 mm
Match
Opposing pad-center spacing
45.31 mm
45.31 mm
Match
Top/bottom pad-row center spacing
26.57 mm
26.57 mm
Match
Current Flux PS1 footprint read-back
Current PS1 layout read-back:
Table
Designator
Center X
Center Y
Layout bounds
Layer
PS1
-43.82 mm
61.20 mm
52.72 mm × 42.58 mm
Top
The current local footprint body/keepout polygon is approximately 52.0 mm × 31.4 mm, which is slightly larger than the datasheet maximum package body and consistent with using a mechanical/courtyard/keepout outline rather than exact body copper size. The broader 52.72 mm × 42.58 mm layout bounds include pads/keepout features and should not be interpreted as the module body size.
PS1 verification conclusion
The PS1 land pattern matches the Silvertel datasheet pad geometry for pad length, width, group pitch, opposing pad spacing, and row spacing. This clears the main SMT footprint geometry check.
Remaining release-gate items:
Perform a final visual 3D overlay using Ag59800_Detailed.step to confirm model origin/orientation, body height, pin-1 side, and courtyard/keepout alignment.
Confirm paste/mask settings and solder-mask-defined pad preference with the assembler.
Confirm the module is only mounted on the top side, per datasheet note not to reflow the module on the underside of the assembly.
Keep enough copper/thermal connection on power pads while avoiding manufacturability issues with overly heavy thermal relief.
Other critical footprints pending verification
U1 LMR33630ADDA: TI DDA/SO PowerPAD land pattern and exposed pad — checked below.
Q1/Q10 DMT6008LFG-13: Diodes PowerDI3333 land pattern and thermal copper — checked below.
C1 EEHZS1V471P: polarity, height, diameter, pad spacing, ripple/ESR, and CP_Elec_10x10 footprint match — checked below.
TI LMR33630ADDA uses the DDA 8-pin HSOIC / PowerPAD SOIC package, nominal body 5.00 mm × 4.00 mm. TI land-pattern examples for DDA PowerPAD SOIC show:
Table
Feature
TI datasheet land-pattern value
Current Flux read-back
Status
Signal pad count
8
8
Match
Signal pad pitch
1.27 mm
1.27 mm
Match
Signal pad size
0.60 mm × 1.55 mm
~0.65 mm × 1.525 mm
Close / acceptable pending fab rules
Exposed pad
DDA PowerPAD, thermal/AGND
~2.60 mm × 3.10 mm
Match to TI DDA0008J example; close to DDA0008B variant
Component bounds
5 × 4 mm body, package/land pattern larger
7.45 mm × 5.50 mm layout bounds
Plausible for pads/courtyard
U1 conclusion
U1 footprint is provisionally acceptable: pad count, pitch, signal pad size, and exposed pad dimensions match or closely track TI’s DDA PowerPAD land-pattern examples. The schematic metadata still says Package or Case Code: TO, which is incorrect metadata for this part and should be cleaned to DDA / HSOIC-8 PowerPAD before final BOM/assembly release. Also verify thermal vias and top/bottom ground copper under the exposed pad after routing.
Q1 / Q10 — Diodes DMT6008LFG-13 Power MOSFETs
Datasheet footprint reference
DMT6008LFG-13 uses Diodes PowerDI3333-8. Datasheet/package information lists nominal body about 3.30 mm × 3.30 mm, max height about 0.85 mm, lead pitch 0.65 mm, and suggested pad-layout dimensions including overall land-pattern span about 3.70 mm with source/gate/drain pad groups.
Current Flux read-back for both Q1 and Q10:
Table
Feature
Datasheet / package expectation
Current Flux read-back
Status
Package family
PowerDI3333-8
Diodes_PowerDI3333-8
Match
Layout bounds
Land pattern slightly larger than 3.3 mm body
4.34 mm × 3.83 mm
Plausible
Lead pitch
0.65 mm
~0.65 mm source/gate pad spacing
Match
Peripheral pads
Small source/gate pads plus drain/thermal pads
Present
Plausible
Main drain/thermal copper
Must support current/thermal dissipation
Center drain pad present; surrounding thermal/copper still layout-dependent
Needs final copper/thermal review
Q1/Q10 conclusion
Q1/Q10 footprints are provisionally acceptable for package geometry: package family, bounds, pitch, and pad grouping are consistent with PowerDI3333-8. Final signoff still requires a routed-layout thermal/current review because these are power-path parts. Confirm the large drain/source copper areas, via/current capacity, and solder paste behavior after routing; do not rely on the footprint alone for thermal performance.
Panasonic EEHZS1V471P is a ZS-series conductive polymer hybrid aluminum electrolytic capacitor, 470uF / 35V, standard size code G16. Panasonic lists the package as approximately 10.0 mm diameter × 16.5 mm height. Recommended land pattern for standard G16 is:
Table
Feature
Panasonic recommended value
Current Flux read-back
Status
Body diameter
10.0 mm
Body/courtyard about 12.75 mm × 10.52 mm
Plausible clearance
Height
16.5 mm
Not represented in 2D footprint
Must verify mechanically
Land pattern a spacing
4.6 mm
Approx. 4.0 mm gap between 4.0 mm pads
Mismatch / needs correction
Pad length b
4.1 mm
4.0 mm
Close
Pad width c
2.0 mm
2.5 mm
Mismatch / needs review
Polarity
Required
Generic P1/P2 pins; polarity not visually signed off
Needs polarity check
C1 conclusion
C1 is not signed off. The current generic CP_Elec_10x10 footprint is close in body clearance, but the pad spacing/width do not match Panasonic’s recommended G16 land pattern, and the 16.5 mm height/polarity must be explicitly verified. Treat C1 as a release blocker until the footprint is adjusted or replaced with a Panasonic EEHZS1V471P/G16-compatible footprint and polarity marking is confirmed.
J1 — Abracon ARJM11D7-114-AB-EW2 RJ45 MagJack
Uploaded footprint reference
Current Flux footprint read-back versus uploaded KiCad reference — resolved
Source / variant evidence
Key mechanical dimensions visible in provided drawing