Audited the scoped Q2 input-protection area and verified the corrected schematic connectivity.
DRC still reports scoped layout problems: VIN_FUSED airwire between F2:P2 and Q2:D, VIN_PROTECTED airwires involving Q2:S, D6:K, and R6:P2, plus stale/dangling trace remnants and an overlap at Q2:D.
❌ Stale traces were identified but not removed in this run.
❌ The physical path is not yet fully routed as J1 P1 -> F2 -> VIN_FUSED -> Q2 -> VIN_PROTECTED -> D3/C7/FB2 -> VIN_FILTERED.
❌ DRC is not clean in the scoped area; airwires/dangling/overlap issues remain.
✅ The corrected schematic topology still supports reverse-polarity blocking, but the PCB must be cleaned/rerouted before fabrication.
Next steps
Perform the physical trace cleanup/reroute in the PCB editor for the listed scoped items, then rerun DRC to confirm the Q2 input-protection area is clear.
Scope: Audit only. No project modifications were made.
Date: 2026-05-11
Verdict
FAIL — do not fabricate before layout and BOM corrections.
The schematic implements a recognizable LM2596 fixed-5V buck topology, but the physical PCB routing/placement is not acceptable for a switching regulator and the catch diode is under-rated and ambiguously documented. The highest-risk issues are D2 being a 1A SS14 while the LM2596 datasheet calls for a catch diode current rating at least 1.3× maximum load current, long/narrow switch-node and power-loop routing, input/output bulk capacitors far from U1, and no evident large thermal copper strategy for U1 GND_TAB.
PCB placement/routing data around U1 and first-hop connected nets.
DRC subset: airwires, dangling traces, overlapping copper, floating copper, trace corner radius, capacitor voltage rating, parts availability.
Datasheet data for LM2596S-5.0/NOPB, SRR1260-680M, and SS14.
Schematic Connectivity
U1 LM2596S-5.0/NOPB
Pins:
Table
U1 pin
Net
Assessment
VIN
VIN_FILTERED
Correct functional input net after protection/filter stage.
OUTPUT
BUCK_SW
Correct switch-node net.
GROUND
GND
Correct.
FEEDBACK
5V
Correct for fixed 5V part: feedback senses regulated output.
~ON~/OFF
GND
Correct for always-on operation. LM2596 datasheet says pulling ON/OFF below about 1.3V turns the regulator on, and tying it to ground or leaving it open keeps it ON.
GND_TAB
GND
Correct net assignment, but layout thermal copper is a concern.
Grounds: C1 pin 2, C2 pin 2, C3 pin 2, C4 pin 2, D2 anode, U1 GROUND, U1 GND_TAB, and U1 ON/OFF are on GND.
Requested Checks
1. D2 role: catch diode vs back-power protection diode
FAIL.
In the schematic, D2 is electrically the LM2596 catch/freewheel diode because it connects from BUCK_SW to GND with cathode at BUCK_SW and anode at GND.
However, D2 properties say:
Role Details: Prevents harmful back-power interaction between rails while allowing simple prototype power OR-ing
That description is not the LM2596 catch-diode role and conflicts with the actual schematic function. D2’s BOM/documentation must be corrected so it is not described as a back-power protection / OR-ing diode.
Required documentation correction: D2 should be described as the LM2596 catch/freewheel Schottky diode from switch node to ground.
2. D2 polarity for LM2596 catch diode
PASS for polarity.
D2 is connected:
Cathode -> BUCK_SW / U1 OUTPUT / L1 pin 1
Anode -> GND
That is the correct polarity for a non-synchronous buck catch diode: it conducts when the switch node swings below ground during the off interval.
3. L1 value and current rating
PARTIAL / LIKELY FAIL for full 3A LM2596 use.
L1 is Bourns SRR1260-680M:
Inductance: 68uH
Tolerance: ±20%
DCR max: 110mΩ
Irms max: 2.10A
Isat typ: 2.10A
The LM2596 datasheet quick-selection table supports 68uH for some 5V cases, especially lower current / high input combinations such as 5V, 2A, 20V–40V max input. But this inductor is not suitable for using the LM2596 as a 3A converter, because both Irms and Isat are 2.10A.
Assessment: acceptable only if the board’s 5V load is intentionally limited below the inductor’s thermal and saturation limits with margin. If this design expects relay + ESP32 only, it may be electrically adequate after load-current validation, but it should not be documented as a 3A-capable LM2596 stage.
4. C1/C2 voltage rating and ESR suitability
C1 input bulk: FAIL for 24V nominal input margin.
C1 is RZW101M1VBK-0811, 100uF, 35V. The LM2596 datasheet states aluminum electrolytic input capacitor voltage rating should be approximately 1.5× maximum input voltage. For a 24V nominal system, that gives 36V minimum before considering automotive/industrial surges or adapter tolerance. Therefore 35V is below the datasheet derating guidance for a 24V nominal input.
Also, C1 is only 100uF while the LM2596 datasheet typical fixed-output example uses 470uF/50V, and the input capacitor RMS ripple current must be checked against approximately 1/2 of DC load current. The C1 datasheet ripple/ESR data was not available from the parsed source, so ESR/ripple suitability remains ambiguous.
C2 output bulk: PARTIAL.
C2 is also 100uF, 35V. Voltage rating is more than adequate for 5V output. Capacitance is within the LM2596 datasheet’s broad output capacitor range of low-ESR electrolytics between 82uF and 820uF, but the datasheet emphasizes ESR as the key stability parameter. Since the C2 ESR/ripple data was not available from the parsed source, output stability/ripple suitability is not fully verified.
Required before fabrication: confirm C1/C2 ESR and ripple current from the exact capacitor datasheet, or use capacitor series explicitly recommended/validated for LM2596 switching service.
5. C3/C4 100nF placement and voltage rating
FAIL / AMBIGUOUS.
C3 and C4 are generic 100nF capacitors and have no voltage rating property recorded.
Placement:
C3 center: approximately (-7.19mm, -26.94mm)
U1 center: approximately (-9.02mm, 4.82mm)
Approximate center-to-center distance: about 31.8mm
C3 is therefore not physically close to U1 VIN/GND, despite being documented as high-frequency VIN bypass near the LM2596.
C4 center: approximately (-34.90mm, -9.62mm)
U1 center: approximately (-9.02mm, 4.82mm)
Approximate center-to-center distance: about 29.6mm
C4 is also far from U1 and appears near the diode/output area rather than tightly across the output capacitor/load return loop.
Required before fabrication: add/relocate high-frequency bypassing so the VIN-to-GND loop is tight at U1 VIN/GND, and ensure C3/C4 have explicit voltage ratings. For a VIN-side 100nF capacitor on a 12V–24V input, use a voltage rating appropriate for the protected VIN rail, not a generic/unrated part.
6. U1 thermal copper area and GND_TAB connection
NET PASS, LAYOUT FAIL / NOT VERIFIED SUFFICIENT.
U1 GND_TAB is connected to GND, which is correct. But the layout data shows the U1 GND_TAB pad with no evident large dedicated copper heat-spreading area or via stitching details in the inspected data.
The LM2596S TO-263 datasheet states the tab is intended to be soldered to PCB copper, with at least 0.4in² copper and ideally two or more square inches of 2oz copper for good thermal behavior. The current inspected layout does not demonstrate that level of thermal copper.
Required before fabrication: provide a large GND copper pour/heat spreader tied to U1 GND_TAB, with thermal vias to inner/bottom GND copper if using the 4-layer board.
7. Switch-node copper length and area
FAIL.
The switch node BUCK_SW is routed as a long trace:
U1 OUTPUT around (-15.42mm, 6.52mm)
Routed through approximately (-20.18mm, 6.52mm), (-23.76mm, 10.10mm), (-35.56mm, 10.10mm), down near (-36.90mm, -5.23mm), and to D2/L1 pads.
D2 is at approximately (-34.85mm, -5.34mm).
L1 is at approximately (-30.75mm, 5.51mm).
This is a large switch-node geometry for a 150kHz buck regulator. The LM2596 datasheet explicitly says the OUTPUT/switch-node copper area must be kept to a minimum to reduce coupling to sensitive circuitry.
Required before fabrication: place D2 and L1 adjacent to U1 OUTPUT so the switch-node copper is short and compact.
D2 is far from U1, and the BUCK_SW trace from U1 OUTPUT to D2 cathode is long. The GND return path from D2 anode back to U1 GROUND/GND_TAB is not shown as a tight local loop in the inspected routing. This violates the LM2596 layout requirement to keep high di/dt loop traces wide and short.
Required before fabrication: move D2 next to U1 OUTPUT and U1 GND/GND_TAB; route cathode directly to U1 OUTPUT and anode directly into the local U1 ground/thermal copper.
L1 and C2 are not placed/routed as a tight output power loop:
U1 center: (-9.02mm, 4.82mm)
L1 center: (-30.75mm, 5.51mm)
C2 center: (-34.36mm, -16.08mm)
The output path is physically spread over roughly 20–30mm scale distances. C2 is not close to L1/U1 ground return. This increases output ripple, EMI, and transient impedance.
Required before fabrication: move L1 and C2 close to U1, with C2 ground returning directly to the same low-impedance ground region as U1 GND_TAB and D2 anode.
10. Relay switching / ESP32 Wi-Fi current pulse droop/reset risk
FAIL / HIGH RISK without layout changes and load validation.
Schematic connectivity alone does not prove droop/reset immunity. Current design risks:
Long/narrow 5V output routing and distributed output capacitor placement.
C2 is only 100uF and ESR/ripple specs are not verified.
L1 is limited to about 2.10A Irms/Isat typical, not a full 3A LM2596 inductor.
ESP32 Wi-Fi bursts can create fast load transients on 5V/3.3V rails; relay coil switching creates supply disturbance and ground bounce risk.
If the LM2596 layout stays spread out, transient response and EMI will be worse, increasing reset risk.
Recommendation: after layout correction, validate with bench testing under relay switching while ESP32 Wi-Fi transmits; monitor 5V and 3.3V rails at the ESP32 module with an oscilloscope.
DRC / Layout Check Results
The selected review checks reported 4 dangling trace warnings:
Trace 1855
Trace 45f1
Trace 4f4c
Trace 8aa5
No airwire errors were returned in the selected review subset, but dangling traces must be resolved before routing signoff because they may indicate stale copper or unintended antennas/stubs.
Electrically used as catch diode, but documented as back-power/OR-ing diode. Rated 1A, 40V; under-rated for LM2596 full-current catch-diode service.
L1 SRR1260-680M
68uH is plausible for reduced-current conditions, but Irms/Isat are 2.10A, below full LM2596 3A capability.
C1 RZW101M1VBK-0811
100uF 35V input bulk; 35V is below LM2596 datasheet 1.5× guidance for 24V nominal input. ESR/ripple not verified from parsed datasheet.
C2 RZW101M1VBK-0811
100uF 35V output bulk; voltage OK for 5V, ESR/ripple not verified.
C3 generic 100nF
No voltage rating property; placed too far from U1 VIN/GND.
C4 generic 100nF
No voltage rating property; placed far from U1/output loop.
U1 thermal copper
GND_TAB net is correct, but sufficient thermal copper/via strategy not verified.
Critical Layout Changes Required Before Fabrication
Re-place U1, D2, L1, C1/CIN, C2/COUT, and C3/C4 as a compact buck cluster.
Move D2 directly next to U1 OUTPUT and U1 GND/GND_TAB. Keep U1 OUTPUT -> D2 cathode -> D2 anode -> U1 GND loop extremely short.
Move L1 adjacent to U1 OUTPUT and 5V output node. Minimize BUCK_SW copper area.
Move C1/CIN close to U1 VIN and U1 GND. Current placement is far away and routed with narrow/long traces.
Move C2/COUT close to L1 output and U1 GND return. Use wide copper for L1-to-COUT and COUT-to-GND return.
Create a large GND copper heat spreader for U1 GND_TAB. Add thermal vias to internal/bottom GND copper.
Increase widths for VIN, BUCK_SW, diode current path, inductor current path, 5V output, and GND returns. Current inspected routes include 0.254mm/0.3mm segments in power paths, which are not appropriate as the main buck current paths.
Correct D2 BOM/role description. It must be documented as the LM2596 catch diode, not as back-power protection.
Replace or re-rate D2 if the 5V rail can exceed roughly 0.77A load. For a full LM2596-capable design, use a Schottky diode meeting the datasheet current requirement and reverse voltage margin.
Resolve dangling traces before signoff.
D2 BOM Description Requirement
Yes — D2 BOM description must be corrected.
D2 is the LM2596 buck catch/freewheel diode in the actual schematic. Its present role details describe back-power protection / OR-ing, which is incorrect and will confuse assembly/debug/review. Additionally, the selected SS14 is not an acceptable full-current LM2596 catch diode because the SS14 average rectified current is 1A while the LM2596 datasheet recommends catch diode current rating at least 1.3× maximum load current.
Final PASS/FAIL
FAIL.
The schematic buck topology is mostly correct, but the implementation is not fabrication-ready because of:
D2 role documentation conflict.
D2 current rating too low for full LM2596 catch-diode service.
C1 input capacitor voltage rating below LM2596 1.5× guidance for 24V nominal input.
Missing/ambiguous ESR/ripple data for C1/C2.
Missing voltage ratings for generic C3/C4.
Poor physical placement and routing for buck high-current/high-di/dt loops.
Long switch-node copper.
Insufficiently verified U1 thermal copper.
Dangling traces reported by DRC.
Verdict
Evidence Reviewed
Schematic Connectivity
U1 LM2596S-5.0/NOPB
Buck power path in schematic
Requested Checks
1. D2 role: catch diode vs back-power protection diode