Project Start Conversation


flux

The HY2120 Kelvin-sensing work completed, but I could not retrieve and reconcile its final report before execution ended.
Confirmed work from this session:
  • Added dedicated Kelvin branches from:
    • U6 VSS → RS1 BATT_NEG-side land
    • U6 CS/R38 → Q2 source land
  • Removed the previous remote sense branches.
  • Preserved component placement, USB routing, MOTOR_B Kelvin routing, high-current copper, and the 0.10 mm spacing rule.
  • Latest verified board state:
    • 0 airwires
    • 0 blocking DRC errors
    • 17 intentional redundant-copper groups retained
  • The last reviewed qualification still had two unresolved release gates:
    • Proving isolation of the Q2 Kelvin pickup via from Bottom/Mid-Layer-2 load-current copper.
    • Conservatively bounding the internal RS1–Q1–Q2 copper resistance and confirming positive margin below the HY2120’s 170 mV minimum overcurrent threshold.
The final executor was specifically working on those two gates, but its result was not available for reconciliation. Therefore, the board is not yet approved for manufacturing, and no new manufacturing exports were generated.
Remaining work:
  1. Retrieve and review the final Kelvin-sensing report.
  2. Confirm the 10.565 A / 500 ms hot overcurrent margin.
  3. Run an independent final ERC/DRC and protection-path review.
  4. Verify JLCPCB BOM stock and via/stencil requirements.
  5. Update firmware and bring-up documentation.
  6. Regenerate Gerbers, BOM, CPL, STEP, PDF, and IPC-D-356 files.
Execution stopped because your ACUs ran out.

Protection Validation
Release status — HOLD
Validation and limited repair of the landed HY2120-CB / 6 mΩ / AON6512 protection set, 2026-09-19. This report supersedes historical S-8252, MAX17320, 1 mΩ and 6.2 V implementation statements in older protection/power-budget files; it does not silently waive any cutoff requirement. The complete board and this protection block are not manufacturing-ready.
Assigned-batch disposition

Table


ItemStatusEvidence / specific blocker
Inspect landed schematic and retain complete substitution setCompletedU6=HY2120-CB C116509; RS1=HoLLR2512-3W-6mR-1% C2985709; Q1/Q2=AON6512 C485679. No replacement or net-membership changes made.
Verify autonomous control and sensing topologyCompletedU6 VSS=BATT_NEG; CS connects through R38 to SYS_GND. RS1 precedes Q1 source; Q1/Q2 drains common; Q2 source=SYS_GND. U2 CHG/DSG explicitly no-connect.
Correct obsolete schematic metadataCompletedRS1 resistance, tolerance, power and datasheet recorded; U6 and R33–R38/C28 descriptions updated. Readback confirms metadata, connections and no-connects; commit 18535393.
Repair malformed local Q1/Q2 footprint overridesCompleted, limitedDisabled six merged-drain/disabled-land overrides, restoring all nine published pads and paste. Component positions unchanged. Q1/Q2 body-overlap warning disappeared. This is not final footprint/stencil approval.
Remove confirmed redundant copper shorting Q2 drainCompletedRemoved nine local SYS_GND stubs. Independent final review confirms copper shorts fell from 13 to 4.
Finish all protection routing and DRC remediationFailed / incomplete19 airwires and 4 shorts remain; includes U6 support/gate connections and two exposed-drain links. No autorouting performed. Remaining shorts require inspected local rerouting, not blind deletion.
Validate 10 A / 500 ms no-trip margin and thermal survivalFailed to qualifyConditional budget below is tight; actual resistance, minimum loaded gate voltage, hot maximum FET resistance and thermal behavior are not established.
Validate short-circuit interruption and cutoff thresholdsFailed to qualifyDetector timing does not bound actual current interruption; gate-drive current, wiring inductance, cell fault current and transient SOA not qualified. Strict 3.00 V/cell minimum cutoff conflicts with the landed 2.90 V nominal part.
Final automated checksCompleted, with limitsFinal review 2026-09-19T03:18:57Z: 19 airwire Errors, 4 overlapping-copper Errors, 7 redundant-trace-group Warnings, 2 Invalid Pads informational findings. Explicit ERC/other DRC query returned no categories, not an affirmative clean-check certificate.
Stencil windowing, assembled tests and manufacturing exportsUnattemptedStencil remains to qualify; unresolved electrical/PCB blockers prohibit release. No manufacturing files generated.
Preserved design
No component was moved, added, removed or substituted. No schematic net membership, board size, stackup, global clearance, external connector, USB route or MOTOR_B Kelvin branch was changed. Effective board remains 40 × 75 mm, Standard 4 Layer with 35 µm copper. The global clearance floor remains 0.10 mm; the tool reports a custom manufacturing profile, not a verified vendor preset.
Power path: BATT_NEG → RS1 6 mΩ → BMS_SHUNT_NEG → Q1 sources → Q1/Q2 common drains → Q2 sources → SYS_GND. Both cells are sensed through BATT_NEG, CELL_MID and pack positive. Monitor U2 retains shunt Kelvin filtering and requires 6 mΩ firmware calibration. It does not control protection gates.
Manufacturer-verified AON6512 pin mapping is 1–3 Source, 4 Gate, 5–8 Drain; the published part additionally exposes drain pad 9. An earlier uncited pinout response was rejected, not used.
Datasheet limits and interpretation
HY2120 OCD is 170/200/230 mV (min/typ/max). OCD delay is 6/10/14 ms. SCP threshold is 0.6/1.0/1.4 V under the specified 7 V supply condition. SCP delay is 150/250/400 µs. These threshold bounds must not be extrapolated beyond their datasheet test conditions without qualification.
The landed U6 metadata records 2.90±0.08 V/cell UV at 25°C, equivalent to 5.64–5.96 V for a balanced pack. This is not a pack-only threshold: either cell may initiate cutoff. It does not guarantee cutoff at or above 3.00 V per cell, 6.0 V pack, or the historical 6.2 V pack requirement. Lead must reconcile the intended requirement and DRV8701 undervoltage operating margin before release; no additional supervisor or substitution was introduced here.
AON6512 RDS(on) maximum is 2.4 mΩ at VGS=4.5 V and 1.7 mΩ at VGS=10 V, at 25°C. Its temperature curve is typical, not a guaranteed hot maximum. The calculations below deliberately use a 1.6× engineering hot envelope; that is an assumption needing validation, not a manufacturer limit.
RS1 tolerance is ±1%. Series PDF TCR information and the distributor listing differ (40 versus 50 ppm/°C); use the conservative 50 ppm/°C assumption until exact-lot confirmation. The 3 W rating is temperature-derated, not a universal hot rating.
Conditional current and pulse budget
Assumed auxiliary outputs from the prior project budget: 3.3 V × 0.55 A + 5 V × 0.15 A = 2.565 W; assumed combined conversion efficiency 85%; driver allowance 30 mA. These are budget assumptions, not measured peak waveforms.
At 5.64 V converter input, auxiliary current = 2.565/(0.85×5.64)+0.030 ≈ 0.565 A. Thus a 10 A actuator pulse requires approximately 10.565 A total, not 10 A. Protection loss and any additional upstream drop lower converter voltage and increase this slightly. Existing 10.5 A net metadata is therefore below this illustrative depleted-pack budget; this report flags it without silently changing global routing constraints.
Illustrative 150°C shunt upper bound using ±1% and 50 ppm/°C: RSH,max = 6 mΩ × 1.01 × (1+50e−6×125) = 6.097875 mΩ. At 10 A, P=0.6098 W and E500ms=0.3049 J. At 10.565 A total, approximately 0.681 W and 0.340 J. Verify the resistor's actual hot derating and mounting conditions.
Assumed RFET,hot = 2.4 mΩ × 1.6 = 3.84 mΩ per device. Shunt plus both FETs totals 13.777875 mΩ before PCB, solder and other sensed interconnect resistance.
For no OCD trip: Itotal × (RSH,max + 2×RFET,hot + Rsensed-interconnect) must remain below 170 mV, with additional allowance for sense offsets, ripple and dynamic effects. A 500 ms pulse greatly exceeds the 14 ms maximum OCD delay; delay cannot rescue a sustained threshold violation.
At 10.565 A, the remaining sensed-interconnect allowance is only approximately 2.31 mΩ with zero extra noise margin. An illustrative 2.00 mΩ allowance gives approximately 166.7 mV sensed drop, only 3.3 mV below the threshold minimum. No actual PCB resistance extraction or hot measurement establishes that allowance. Lower converter-input voltage further reduces the margin. This is not a verified no-trip design.
At the same current, each FET dissipates approximately 0.429 W during the pulse, or 0.214 J over 500 ms, under the assumed 3.84 mΩ envelope. Repetition rate, enclosure ambient, copper area and junction temperature remain unqualified.
Overcurrent and fault-current bounds
Using 6 mΩ + 2×2.4 mΩ at 25°C and ignoring PCB resistance gives 15.74–21.30 A OCD threshold arithmetic. This is an illustrative resistance model, not a guaranteed current range, because minimum FET resistance is unspecified and resistance changes with gate voltage and temperature.
A conservative shunt-only minimum estimate over ±125°C temperature deviation is 6 mΩ×0.99×(1−50e−6×125)=5.902875 mΩ. With nonnegative added path resistance, the 230 mV threshold corresponds to no more than approximately 39.0 A static OCD detection current under the assumptions. Likewise 1.4 V gives approximately 237 A static SCP detection current, only at applicable comparator conditions. These are not peak short-circuit current limits or safe fault-interruption ratings.
HY2120 output-high information alone does not establish loaded gate drive or turnoff current. R33=100 Ω and R34=1 kΩ remain unchanged. Actual gate discharge, Miller interval, cell/wire inductance, avalanche and MOSFET SOA must be assessed. The AON6512 450 A pulsed-current rating is conditional and does not independently prove fault survival.
The quoted maximum RθJA of 55°C/W is tied to the datasheet thermal conditions. Its reference board uses 1 in² FR4 with 2 oz copper, not this board's 35 µm copper. Therefore neither steady-state nor transient reference curves certify assembled-board temperatures.
PCB findings and repair record
Disabled rule UIDs: 84e7dd2d-5320-490e-b90b-cd6f3542bfe8, 98479488-d7b6-4b7d-baa1-1ef7ab631fbb, 34e45261-6045-4d4f-b6a2-17cc86da58d5, 0629a1a2-4a09-4837-9763-6b42086aece9, e94cfc10-ca1f-4e04-8557-74c4ef0b6311, 514d1c1a-1ab8-48d1-97f0-22e1c0afeb13. Restored published land geometry eliminates the displaced merged pad and −3 mm paste suppression. Q1/Q2 bounds are now 5.45 × 6.72 mm at unchanged (10,25.8) and (10,18.4) mm centers.
The checker reports exposed-pad-to-drain airwires despite nominal edge contact in the published geometry. Establish explicit, adequately wide copper overlap/connectivity and verify manufactured copper rather than dismissing those airwires. Do not carry 10 A through a narrow signal-width repair.
Nine deleted redundant SYS_GND trace suffixes: 25b450293d074de0d9f5ae6736fbb396; 54ac5b10964a672b8af351a5c21dd5c5; 9ff62c163c6872782836c604d33ba382; e804a7034d6d82aa2725008b0f604918; 273bdd923c85fac0f7727fe1458d9240; 7e500e274cbc9f12ffb122f82a49be80; d262e7ae336314fa34f84cb033105b72; fdd3928f07e8e58e3077c23836e94a82; 723517f80dc14fd658aa07f4498dceb3. All were checker-confirmed redundant and shorting Q2 exposed drain.
Remaining short pairs:
  • BATT_NEG trace ending 3bc0ec88051ba507530cf110069ebf7d against trace 81dae967-8316-40da-a7b3-3c50e98e8370.
  • The same BATT_NEG trace against Q2 Gate. Its inspected endpoints are (15.500011,18.882563) to (10.272803,13.655355) mm, Top.
  • BATT_NEG widened trace ending 30ce91d6bb821f44f52f6da5bce6749e against BATT_TEMP trace ending 2d9501416309272b92dc324e69d67ca4.
  • BMS_SDA via ending bc0aeb5f20c64a599c578e8fc60471f6.throughHole.0-0 against f9508537-38dc-4002-9330-56dfe3aab499.
Airwires include U6 VDD/VC/CS/VSS support, Q2 gate support and exposed drains; additional U2 cell-sense and U1 ground findings lie outside the limited protection repair. Remaining redundancy is Warning (possibly wrong), not automatically a deletion instruction. Invalid Pads entries for Q1/Q2 are informational, not proof of a defective pad. Explicit queries for ERC, floating/dangling copper, missing footprints, keepout, board boundary and stackup returned empty categories at 03:19:11Z; they do not establish affirmative pass coverage.
Restored EP paste is not yet windowed/approved. Generic DFN/QFN guidance for pitch ≥0.5 mm recommends 70–80% center-pad paste coverage and perimeter apertures equal to PCB pads. Recommended stencil thickness in that guidance is 0.075–0.127 mm. This is generic process guidance, not an AON6512-specific production signoff. Agree windowing and paste volume with the assembler before export.
Sourcing and release gates
Exact U6 and RS1 library entries were found and identify Extended parts. Q1/Q2 use the existing published user part UID 5f720041-cd81-4255-8fc3-dc5533735cd3; an empty keyword search does not invalidate that existing part. Stock observations are time-sensitive, not procurement guarantees; independently confirm JLCPCB availability of all exact MPNs before assembly.
Required before release: resolve cutoff-requirement conflict; repair local and separately authorized out-of-scope PCB issues; positively verify ERC/clearance/check coverage; measure/extract sensed path resistance and loaded gate voltage; qualify hot pulse/repetition behavior; qualify fault interruption/SOA and transient clamps; approve pad/paste/assembly process; update current budgets and firmware calibration; then regenerate and review manufacturing outputs. Do not energize this PCB with an unrestricted battery while copper shorts or protection airwires remain.
  • Release status — HOLD

  • Assigned-batch disposition

  • Preserved design

  • Datasheet limits and interpretation

  • Conditional current and pulse budget

  • Overcurrent and fault-current bounds

  • PCB findings and repair record

  • Sourcing and release gates