Board Bring-Up Plan — Solar Balcony Irrigation Controller
Prerequisites
  • Equipment: current-limited 12 V bench supply, multimeter, oscilloscope if available, USB cable/programmer for ESP32-S3 dev board.
  • Start with no pumps connected and F1/F2 fitted with the correct fuses.
  • This board is low-voltage DC only; do not connect mains wiring.
Power rail verification

Table


RailSourceExpectedMeasure atInitial current limitPass criteria
+12V_BATJ_BAT pin 110.5-14.7 V AGM systemJ_BAT / TP200 mA no-loadCorrect polarity, no heating
+12V_FUSEDF1 after D7/F1+12V_BAT minus D7 dropTP_12V_FUSED200 mA no-loadWithin expected diode drop
+12V_PUMPNT_PUMP outputSame as +12V_FUSEDTP1 / pump pin 1no pumps connectedContinuity to pump pin 1
+12V_LOGIC_FUSEDF2 output+12V_FUSEDPS1 VIN200 mA no-loadPresent before regulator
+5VPS1 output5.0 V +/-5%TP12 / SEN0204 pin 1500 mAStable 5 V
+3V3ESP32 dev board3.3 V +/-5%TP2 / I2C pin 1via ESP32 boardStable 3.3 V
+3V3_SENSORQ6 switched rail0 V at reset, 3.3 V when GPIO21 LOWTP10 / soil pin 1<100 mA sensorsOFF by default, ON only when enabled
Critical default-state checks
  • Q1-Q5 gates must be held near 0 V by 100 k pulldowns at reset.
  • Q6 base must be pulled to +3V3 by 100 k so +3V3_SENSOR is OFF at reset.
  • GPIO4 button input should read HIGH idle and LOW when pressed.
  • LEVEL_EMPTY must be checked by firmware before enabling pump outputs.
Functional validation
  1. Power the ESP32-S3 dev board and confirm serial boot output.
  2. Run an I2C scan on GPIO8/GPIO9. Expected addresses: ADS1115 modules at 0x48 and 0x49; BME280 typically 0x76 or 0x77.
  3. Toggle GPIO21 LOW and verify +3V3_SENSOR rises to 3.3 V, then HIGH/floating returns it OFF.
  4. Apply known voltages to each soil input below 2.9 V and verify corresponding ADS channel readings.
  5. With pumps disconnected, toggle GPIO12-GPIO16 one at a time and measure each MOSFET gate test point.
  6. Connect one pump at a time, verify correct zone terminal polarity, and confirm flyback diode orientation does not short the rail.
  7. Trigger SEN0204 reserve and empty sensors and confirm GPIO17/GPIO18 divider outputs are about 3.0 V for 5 V OUT.
Pass/fail summary
  • Visual inspection: [ ] Pass / [ ] Fail
  • Power rails: [ ] Pass / [ ] Fail
  • ESP32 boot: [ ] Pass / [ ] Fail
  • I2C devices: [ ] Pass / [ ] Fail
  • Sensor power switching: [ ] Pass / [ ] Fail
  • Pump outputs: [ ] Pass / [ ] Fail
  • Water-level safety input: [ ] Pass / [ ] Fail