PCB GND Repair
Table
| Assigned item | Status | Specific evidence or blocker |
|---|---|---|
| Rated positive terminal and wiring | Completed | J4 sourced,placed,wired,routed,both pins positive,readback verified |
| Wire choice/preparation and strain-relief specification | Completed specification | Belden83009/terminal instructions documented; installed harness tests unattempted |
| Q copper correction and pin/net preservation | Completed | TI drawing; seven-pad selector matches;0airwires restored; complete32net readback |
| U1 copper/paste rule correction | Completed | PW0020A geometry readback; native connectivity preserved |
| Q split-window stencil/mask/local clearance closure | Failed to complete | Exact split-window stencil not authored; assembler-controlled aperture acceptance required;0.15mm source/gate gap versus0.2mm board minimum needs local fab/rule reconciliation |
| Connector drilling evidence | Completed nominal comparison | J1 drawing visually verified;J2/J3 lead drilling evidence agrees with unchanged layout;J4 sourced drawing agrees |
| External mating-view/physical interface qualification | Failed to complete | Exact mating-plug orientation/procurement sign-off still missing for J1–J3; no physical mate test |
| Stackup physical layers | Completed configuration | 1.530FR4+0.035+0.035=1.600mm laminate;sizeZ1.6 |
| Stackup metadata and saved profile | Failed | Tool totalThickness1.53mm persists; save profile denied because acting editor is not owner nico; owner must save in stackup editor |
| Router generic-preflight recovery | Completed observation | Generic failure no longer reproduced; no route rip-up needed |
| Locked redundant neckdown cleanup | Failed | Node locked;active=false but still reported/visible; export omission unverified |
| Timing recovery | Completed | Read controller specification/safety files,30.517578kHz and256ns recovered |
| Actual5V drive/switching/thermal/blank qualification | Unattempted physical test | No guaranteed5V MOSFET RDS(on); actual ambient,cooling,load details and optical-extinction deadline absent |
| Filled-GND/C1 return/current-path proof | Failed to establish | No generated fill contours or numerical current-density/DC-drop results from native inspections; no fabrication-file proof |
| Documentation and fresh read-only checks | Completed | Four updated files; net/geometry/routing/check evidence above |
| Manufacturing output/stock/assembler/lab acceptance | Unattempted | No fabrication-approved export,order,physical build or supplier acceptance |
neckdown-trace-customshape-6993b82d-c1de-4faf-84c8-fec748587adc-7bc57d53-1c75-4999-8db8-c372a0eb71f9-1787659060940-4. Its active=false rule does not prove export omission.Changes Completed
Verification Evidence
Item Status and Remaining Blockers
Unwaived Findings
Handoff