PCB Design Questions
flux
BOARD_DEFINITION_GENERIC validation error without identifying the underlying object.flux
flux
Table
| Rail | Load | Typical | Peak |
|---|---|---|---|
| 3.3 V | ESP32-WROOM-32D | 150 mA assumed active average | 500 mA Wi-Fi burst |
| 3.3 V | I2C + 1-Wire external sensors | 20 mA allowance | 50 mA allowance |
| 3.3 V | Pull-ups and control bias | <2 mA | <5 mA |
| 5 V | SN74AHCT125 | <1 mA static | 10 mA allowance including switching |
| 5 V | FT231XS-R USB bridge | low tens of mA while connected | 10 mA budget increment above prior estimate |
| 5 V | Four external switched loads | application-dependent | 800 mA continuous total |
| 5 V | External logic loads from J3 | not powered by signal pins | negligible onboard |
(5.0 - 3.3) x 0.172 = 0.29 W.(5.0 - 3.3) x 0.555 = 0.94 W.Rail Loads
Totals
USB-C Source and PPTC Limits
Regulator Sizing and Thermal Check
Power-Path Design Requirements
Assumptions and Risks