FMEA Report Generation
Table
| Component | Key specs (from properties / datasheet if available) |
|---|---|
| C1 | 10 uF polarized capacitor, VR 16 V DC, VS 18.4 V DC, IRIPPLE 2200 mA max (100 kHz @ 105 C), operating temperature -55 to +105 C. Datasheet: https://www.we-online.com/katalog/datasheet/875105359001.pdf |
| R1 | 500 ohm, 0603. Power rating, tolerance, tempco, and max working voltage not specified in project. |
| R2 | 500 ohm, 0603. Power rating, tolerance, tempco, and max working voltage not specified in project. |
| R3 | 500 ohm, 0603. Power rating, tolerance, tempco, and max working voltage not specified in project. |
Table
| ID | Process step / function | Item | Potential failure mode | Potential failure effect(s) | Potential cause(s) / mechanism(s) | Current controls (prevention/detection) | S | O | D | RPN | Action recommended | Owner | Status | Assumptions / notes |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | Assembly / BOM definition | R1 | Wrong resistance value populated | Circuit behavior incorrect (biasing, divider ratios, current limit wrong) | BOM/placement error; unbounded generic part; poor variant control | Visual inspection; DMM sample test (if used) | 6 | 4 | 4 | 96 | Replace generic resistor with a specific MPN including tolerance, power rating, and voltage rating; add BOM check (MPN + value) and optional ICT resistance test | EE/MFG | Open | Generic component has no tolerance/power data in project |
| 2 | Assembly / soldering | R1 | Open circuit (tombstone / lifted end / cracked joint) | Net becomes open -> functional failure or intermittent operation | Reflow imbalance; insufficient paste; pad design; board flex | Visual inspection; AOI | 7 | 3 | 6 | 126 | Verify 0603 footprint and paste stencil; add AOI criteria; add mechanical constraints to prevent PCB flex during depanelization | MFG | Open | No layout review data included here |
| 3 | Assembly / soldering | R1 | Short to adjacent net | Unintended current path; possible overcurrent/overvoltage of other parts | Excess solder; paste bridging; contamination | AOI; electrical test | 8 | 2 | 4 | 64 | Tighten solder mask expansion; improve DFM checks; add powered functional test with current limit | MFG/EE | Open | Assumes powered testing is part of production flow |
| 4 | Electrical operation | R1 | Resistor overheats / drifts / fails open | Value drift -> incorrect operation; or open -> loss of function | Excess dissipation; insufficient power rating; elevated ambient | None defined (power rating unknown) | 7 | 3 | 8 | 168 | Define operating voltage/current and select resistor with adequate power rating and derating; add calculation to design notes; consider higher package (0805) if needed | EE | Open | Cannot verify without operating voltage/current and resistor power rating |
| 5 | Assembly / BOM definition | R2 | Wrong resistance value populated | Incorrect circuit behavior; cascading mis-bias or incorrect load | BOM/placement error; generic part | Visual inspection; DMM sampling | 6 | 4 | 4 | 96 | Same as ID 1 for R2: lock down MPN and tolerance; test | EE/MFG | Open | |
| 6 | Electrical operation | R2 | Resistor fails short or low-ohms (rare) | Overcurrent in connected nets; may stress R1 / R3 / C1 depending on topology | Manufacturing defect; conductive contamination; solder bridge behaving like short | AOI; in-circuit resistance tests | 7 | 1 | 6 | 42 | Add ICT resistance checks between key nets; cleanliness controls; conformal coat if environment is harsh | MFG | Open | Functional impact depends on intended circuit function (not defined) |
| 7 | Assembly / BOM definition | R3 | Wrong resistance value populated | Incorrect current/voltage distribution; potential C1 stress | BOM/placement error | Inspection; DMM sampling | 7 | 4 | 4 | 112 | Lock down R3 with MPN and tolerance; add test coverage | EE/MFG | Open | |
| 8 | Assembly / polarity control | C1 | Polarized capacitor installed reversed | According to datasheet: reverse voltage can damage/destroy capacitor; can lead to malfunction | Assembly polarity error; ambiguous silkscreen; footprint polarity marking mismatch | AOI (polarity); visual inspection | 9 | 2 | 4 | 72 | Ensure footprint pin-1/polarity is correct; add clear silkscreen + assembly drawing polarity marking; AOI polarity rule; consider using non-polarized capacitor if acceptable | EE/MFG | Open | Datasheet explicitly warns reverse voltage can damage/destroy |
| 9 | Electrical operation / overvoltage | C1 | Overvoltage beyond rated | Datasheet: leakage increases drastically, lifetime shortens; worst case short-circuit failure mode | Supply overshoot; hot-plug; incorrect rail; transient | None defined | 9 | 3 | 9 | 243 | Verify maximum DC voltage internal heating -> degraded life or failure | Datasheet: excessive heat; lifetime shortage; deterioration; possible parameter drift | High AC ripple; inadequate capacitance selection; high ESR operation; high ambient | None defined |
| 11 | Electrical operation / temperature | C1 | Operated outside -55 to +105 C or high temperature reducing life | Reduced lifetime; param drift; potential venting in extreme cases | High ambient; self-heating from ripple; proximity to hot parts | None defined | 7 | 4 | 8 | 224 | Place away from heat sources; validate thermal rise; ensure ambient + self-heating stays within operating range; consider higher temp-rated part or derating | EE/ME | Open | Datasheet: operating temperature -55 to +105 C; lifetime correlates with temperature |
| 12 | Assembly / soldering profile | C1 | Reflow profile out of spec -> damage / latent defect | Early-life failures; param drift; reduced reliability | Incorrect oven profile; multiple reflows beyond spec | Process control (if present) | 7 | 3 | 6 | 126 | Enforce datasheet reflow profile (J-STD-020E). Key values: Tsmin 150 C, Tsmax 200 C, preheat 60-120 s, TL 217 C, tL 60-150 s, ramp-up 3 C/s max, ramp-down 6 C/s max, 25C to peak 8 min max | MFG | Open | Datasheet states profiles outside spec void warranty |
| 13 | Mechanical handling | C1 | Board flex cracks component or solder joints | Intermittent or open; latent reliability issues | Depanelization stress; mounting torque; shock | None defined | 6 | 4 | 7 | 168 | Follow datasheet: do not apply flexural/compressive force; add mechanical keepout near edges; specify depanel method; add mounting torque spec | ME/MFG | Open | Datasheet contains explicit mechanical mounting caution |
| 14 | Net integrity | Net 1 (between R3 and R2) | Miswire / unintended short to Net 2/Net 3 | Functional error; possible overstress depending on voltages | PCB solder bridge; copper short; schematic misconnections | DRC; AOI; continuity test | 8 | 2 | 5 | 80 | Add net name intent (rename Net 1/2/3 to functional names), add test pads or ICT points as needed, ensure clearance rules are appropriate | EE/MFG | Open | Topology intent unknown; currently nets are unnamed |
| 15 | System definition | Entire schematic | Missing operational parameter definition (voltage/current/temp/environment) | Inability to verify ratings/derating; elevated risk of latent failures | Requirements not captured; generic parts used | Informal review | 8 | 6 | 10 | 480 | Add a requirements section defining: max/min rail voltages on each net, expected load currents, ambient range, ripple frequency; then revisit FMEA and update S/O/D with grounded estimates | EE/PM | Open | This row flags a process gap; highest RPN due to low detectability pre-build |
Unique component specifications captured
Schematic connectivity context
FMEA table
Recommended next steps to improve FMEA quality