Project Start
Waiting for input
Table
| Subsystem | Failure mode | Effect | Severity (1–10) | Likelihood (1–10) | Detection (1–10) | RPN | Mitigation |
|---|---|---|---|---|---|---|---|
| Mains input wiring | Line/neutral contact accessible or insulation damaged | Electric shock, fire | 10 | 3 | 8 | 240 | Touch-safe enclosure and connector, strain relief, protective barriers, qualified assembly, hipot and earth-bond testing as applicable |
| Mains fuse | Incorrect rating/type or bypassed fuse | Conductors/components overheat during fault | 10 | 3 | 7 | 210 | Use specified safety-approved time-delay fuse; prohibit substitution; verify interrupt rating for installation category |
| MOV | Sustained overvoltage or end-of-life short | Heating or fire | 9 | 3 | 7 | 189 | Fuse upstream of MOV, flame-retardant spacing/enclosure, confirm MOV energy/rating and required thermal protection |
| AC/DC module isolation | Internal isolation breakdown or PCB creepage violation | Hazardous voltage reaches SELV outputs | 10 | 2 | 9 | 180 | Certified IRM-90-24 module, maintain datasheet creepage/clearance and primary-secondary keepout, hipot test completed assembly |
| 24 V output | Regulator/module overvoltage | Damage to all downstream loads | 8 | 3 | 6 | 144 | Confirm module OVP behavior; consider secondary TVS/crowbar if attached loads require tighter protection |
| 12 V buck | Feedback open/short or switch failure | 12 V rail overvoltage/undervoltage | 7 | 3 | 6 | 126 | Datasheet layout, qualified resistors, output protection, power-good monitoring where system safety requires it |
| 5 V buck | Feedback open/short or switch failure | Damage to 5 V loads and LAN subsystem | 8 | 3 | 6 | 144 | Datasheet layout, rated output capacitors, validate startup/short-circuit response and load transients |
| Output protection | Fuse/PTC fails short or is oversized | Connector/cable overheats under short | 8 | 3 | 7 | 168 | Validate trip curves at worst ambient; rate connector and copper above protection threshold; short-circuit testing |
| Output connector | Reversed or loose wiring | Load damage, arcing, intermittent operation | 7 | 4 | 5 | 140 | Keyed/polarized connectors where possible, clear polarity labels, retention and torque requirements |
| Thermal management | AC/DC module or buck converter overheats | Shutdown, accelerated aging, fire in extreme fault | 9 | 4 | 6 | 216 | Thermal simulation and chamber testing at full simultaneous load, copper/airflow per datasheet, temperature margin |
| Shared secondary ground | Ground conductor opens | Unexpected voltage references and interface damage | 6 | 3 | 6 | 108 | Adequately rated ground paths/connectors, star/distributed returns sized for total current, continuity test |
| LAN9646 rail/interface | LAN9646 circuitry omitted or incorrectly integrated | Networking function unavailable or damaged | 6 | 6 | 2 | 72 | Do not release until exact component, package, datasheet, host mode, PHY/media configuration and reference design are confirmed |
Scope
Failure Mode Table
Highest-Priority Actions