Finding 48V DC Screw Terminal
Thought for 4 mins 5 sec
flux
265 days ago
Got it: you need a PCB screw-terminal rated for 20 A at 48 VDC. Here are library parts that meet or exceed 20 A per their datasheets.
Recommended options
2EDGRC-5.08-02P-14-100A(H)
Datasheet specs: Rated current: 100 A; Rated voltage: 320 V; Pitch: 5.08 mm; Orientation: side-entry (right-angle).
Notes: Enormous current headroom for 20 A at 48 VDC.
691137710002
— Würth WR-TBL 5.0 mm, 2-pos
Datasheet specs: Rated current: 16 / 24 A; Working voltage: 300 / 250 V; Pitch: 5.00 mm; Wire: 12–30 AWG. Datasheet:
https://www.we-online.com/katalog/datasheet/691137710002.pdf
Notes: Meets 20 A under its 24 A rating; verify which standard/approval applies for your compliance needs.
2-1437667-4
— TE Connectivity barrier terminal, 2-pos
Datasheet specs: Rated voltage: 300 V; Wire size: 22–12 AWG.
Notes: Current rating not found in the file snippet; likely suitable but needs confirmation from the full TE datasheet.
Also viable (barrier style, larger pitch)
HB825-8.25-BK01-04P-Cu-S-A
Datasheet specs: Rated current: 20 A; Rated voltage: 250 V AC/DC; Pitch: 8.25 mm; Wire gauge: up to 8 AWG.
Notes: Shown variant is 4-pos; series includes 2-pos options if you need exactly 2.
Questions to finalize
Entry style preference: side-entry (horizontal) or top-entry (vertical)?
Any pitch constraints (5.0/5.08 mm vs 7.5/7.62/8.25 mm)?
Wire gauge you plan to clamp (e.g., 12 AWG vs 8–10 AWG)?
If you pick one, I can proceed to verify footprint fit and add it to your project.
S
scanneo
265 days ago
can you clear this pcb
Thought for 1 min 29 sec
flux
265 days ago
I can’t clear the PCB for you automatically. Here’s what the Flux documentation says about deleting things in the PCB editor:
“How do I delete a component, wire, or trace?
Select the object and press Del.
Right-click and choose Delete.
Use Ctrl + Z to undo changes.”
Source
What would you like to clear exactly?
All routed traces?
Copper fills?
Components from the board (keeping the schematic)?
Board size/outline?
Delete all traces
Remove copper fills
Unplace components
Reset board outline
Clear everything manual steps
Agent
Chat
Sign up to send
Files
Pins
Symbol
Layout
3D View
No documents yet