Project Start
J_TX_RF_STAGE is flush on the left edge; U_TX_CTRL is rotated to face its antenna pins toward that edge; J_TX_DATA and J_TX_HK are aligned in a 12 mm-spaced pair to the right. The antenna-side corridor is clear of the data connectors.U_RX_CTRL, protection, media bridge, and receiver support parts. The existing safe low-voltage nets—including RX_VBUS_PROTECTED, GND, USB 2.0, USB-C CC/SuperSpeed, and I²C—are already defined.U_MFI_LIGHTNING, U_MFI_30PIN) are intentionally excluded from the PCB and have no defined physical package, so they cannot be placed until an approved MFi part/package or an explicitly generic placeholder footprint is selected.Waiting for input
Diagram
Table
| Group | Reference match | Decision |
|---|---|---|
| Certified mains conversion | None suitable without final voltage/power tier and regional certification | External subsystem connectors only |
| Housekeeping and control | Close references may exist, but the approved architecture leaves rail/input/module certification open | Use a real pre-certified BLE MCU module plus explicit regulator interface |
| Safety shutdown | None: safety integrity level and timing components unresolved | Explicit independent controller/watchdog and gate-inhibit connectors |
| GaN RF power and array | None: frequency, topology, exposure and aperture unresolved | Multi-pin engineering interface blocks only |
| Receiver RF-to-DC/power policy | None: rectifier frequency and power envelope unresolved | Rectenna, PMIC, reverse-block, and protected-power interfaces |
| Receiver control/security | From scratch using real BLE module and secure element | Datasheet-supported low-voltage logic only |
| Capsule interfaces | Connector-level architecture | Real standard connectors where confidently available; MFi placeholders expose only licensed interface groups |
Scope and safety boundary
Functional-group sourcing decisions
Inter-block interfaces